Allen&Heath WZ4 14-4-2 User Manual

MixWizard WZ4 14:4:2
USER GUIDE
Publication AP8666
Limited One Year Warranty
This product is warranted to be free from defects in materials or workmanship for period of one year from the date of purchase by the original owner.
To ensure a high level of performance and reliability for which this equipment has been designed and manufactured, read this User Guide before operating. In the event of a failure, notify and return the defective unit to ALLEN & HEATH Limited or its authorised agent as soon as possible for repair under warranty subject to the following
conditions
Conditions Of Warranty
The equipment has been installed and operated in accordance with the instructions in this User Guide.
The equipment has not been subject to misuse either intended or accidental, neglect, or alteration other than as described in the User Guide or Service Manual, or approved
by ALLEN & HEATH. Any necessary adjustment, alteration or repair has been carried out by ALLEN &
HEATH or its authorised agent.
This warranty does not cover fader wear and tear. The defective unit is to be returned carriage prepaid to ALLEN & HEATH or its
authorised agent with proof of purchase.
Units returned should be packed to avoid transit damage. In certain territories the terms may vary. Check with your ALLEN & HEATH agent for
any additional warranty which may apply.
This product complies with the European Electromagnetic Compatibility directive 2004/108/EC and the European Low Voltage directive 2006/95/EC.
This product has been tested to EN55103 Parts 1 & 2 2009 for use in Environments E1, E2, E3, and E4 to demonstrate compliance with the protection requirements in the European EMC directive 2004/108/EC. During some tests the specified performance figures of the product were affected. This is considered permissible and the product has been passed as acceptable for its intended use. Allen & Heath has a strict policy of ensuring all products are tested to the latest safety and EMC standards. Customers requiring more information
about EMC and safety issues can contact Allen & Heath.
NOTE: Any changes or modifications to the console not approved by Allen & Heath could void the compliance of the console and therefore the users authority to operate it.
Allen & Heath WZ4 14:4:2 User Guide AP8666 Issue 1
Copyright © 2013 Allen & Heath Limited. All rights reserved
Allen & Heath Limited
Kernick Industrial Estate, Penryn, Cornwall, TR10 9LU, UK
http://www.allen-heath.com
Allen & Heath 2 WZ
4
Safety Instructions
WARNING -
Read the following before proceeding :
CAUTION
ATTENTION: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR
Read instructions: Retain these safety and operating instructions for future reference. Adhere to all
warnings printed here and on the console. Follow the operating instructions print­ed in this User Guide.
Do not remove cover: Operate the console with its covers correctly fitted. Disconnect mains power by
unplugging the power cord if the cover needs to be removed for setting internal options. Refer this work to competent technical personnel only.
Power sources: Connect the console to a mains power unit only of the type described in this User
Guide and marked on the rear panel. Use the power cord with sealed mains plug appropriate for your local mains supply as provided with the console. If the pro­vided plug does not fit into your outlet consult your service agent for assistance.
Power cord routing: Route the power cord so that it is not likely to be walked on, stretched or
pinched by items placed upon or against it.
Grounding: Do not defeat the grounding and polarisation means of the power cord plug. Do
not remove or tamper with the ground connection in the power cord
WARNING: This equipment must be earthed.
Water and moisture: To reduce the risk of fire or electric shock do not expose the console to rain or
moisture or use it in damp or wet conditions. Do not place containers of liquids on it which might spill into any openings.
Ventilation: Do not obstruct the ventilation slots or position the console where the air flow
required for ventilation is impeded. If the console is to be operated in a rack unit or flightcase ensure that it is constructed to allow adequate ventilation.
Heat and vibration: Do not locate the console in a place subject to excessive heat or direct sunlight as
this could be a fire hazard. Locate the console away from any equipment which produces heat or causes excessive vibration.
Servicing: Switch off the equipment and unplug the power cord immediately if it is exposed
to moisture, spilled liquid, objects fallen into the openings, the power cord or plug become damaged, during lightning storms, or if smoke, odour or noise is noticed. Refer servicing to qualified technical personnel only.
Installation: Install the console in accordance with the instructions printed in this User Guide.
Do not connect the output of power amplifiers directly to the console. Use audio connectors and plugs only for their intended purpose.
Allen & Heath 3 WZ
4
Safety Instructions
Important Mains plug wiring instructions.
The console is supplied with a moulded mains plug fitted to the AC mains power lead. Follow the instructions below if the mains plug has to be replaced. The wires in the mains lead are coloured in accordance with the fol­lowing code:
!
TERMINAL WIRE COLOUR
European USA/Canada
L LIVE BROWN BLACK
N NEUTRAL BLUE WHITE
E EARTH GND GREEN & YELLOW GREEN
The wire which is coloured Green and Yellow must be connected to the terminal in the plug which is marked with the letter E or with the Earth symbol. This appliance must be earthed.
The wire which is coloured Blue must be connected to the terminal in the plug which is marked with the letter N.
The wire which is coloured Brown must be connected to the terminal in the plug which is marked with the letter L.
Ensure that these colour codes are followed carefully in the event of the plug being changed.
General Precautions
Damage :
Environment :
Cleaning :
To prevent damage to the controls and cosmetics avoid placing heavy objects on the control surface, scratching the surface with sharp objects, or rough handling and vibra­tion.
Protect from excessive dirt, dust, heat and vibration when operating and storing. Avoid tobacco ash, smoke, drinks spillage, and exposure to rain and moisture. If the console becomes wet, switch off and remove mains power immediately. Allow to dry out thoroughly before using again.
Avoid the use of chemicals, abrasives or solvents. The control panel is best cleaned with a soft brush and dry lint-free cloth. The faders, switches and potentiometers are lubricated for life. The use of electrical lubricants on these parts is not recommend­ed. The fader and potentiometer knobs may be removed for cleaning with a warm soapy solution. Rinse and allow to dry fully before refitting them.
Transporting :
Hearing :

Allen & Heath 4 WZ
The console may be transported as a free-standing unit or mounted in a rack or flightcase. Protect the controls from damage during transit. Use adequate packing if you need to ship the unit.
To avoid damage to your hearing do not operate any sound system at excessively high volume. This also applies to any close-to-ear monitoring such as headphones. Continued exposure to high volume sound can cause frequency selective or wide range hearing loss.
4
Introduction
Welcome to the Allen & Heath WZ4 14:4:2, the latest generation of the popular MixWizard series of compact audio mixing consoles. We have tried to keep this
user guide brief and to the point. Please read it fully before starting. Included is information on installing, connecting and operating the console, panel drawings, system block diagram and technical specification. For further information on the basic principles of audio system engineering, please refer to one of the specialist publications and resources available from bookshops, audio equipment dealers and the Internet.
Whilst we believe the information in this guide to be reliable we do not assume re­sponsibility for inaccuracies. We also reserve the right to make changes in the in­terest of further product development.
We are able to offer further product support through our world-wide network of ap­proved dealers and service agents. You can also access our Web site on the In­ternet for information on our full product range, our company pedigree, assistance with your technical queries, our contact details or simply to chat about matters au­dio ( www.allen-heath.com ).To help us provide the most efficient service please keep a record of your console serial number, and date and place of purchase to be quoted in any communication regarding this product.
Contents
Warranty ................................................. 2
Safety Instructions ................................. 3
General Precautions .............................. 4
Introduction ............................................ 5
Front Panel Layout ................................ 6
Introducing the MixWizard ..................... 7
Console Connectors ............................ 13
Mono Input Channel ............................ 15
Stereo Input Channel........................... 17
Group/Aux masters .............................. 18
Master Section ..................................... 19
Talkback, Generator and Matrix .......... 20
Installing the Console ............................ 8
Connecting Power ................................. 9
Connection Pin-outs and Cables ........ 10
Audio Connections .............................. 11
Connector Panel Layouts .................... 12
Allen & Heath 5 WZ
Specifications ...................................... 21
System Block Diagram ........................ 23
User Options ........................................ 24
Cue Sheet ............................................ 27
4
LAMP
0
-5
GAIN
+48V
PAD
(LINE)
0
30
40
20
GAIN
HF
HM
LM
- 10 10
700
45
1k
500Hz
70
35Hz
50
60 40
HPF
TO
GAIN
3k
4k
6k
15k
180
250
400
1k
LF
AUX AUX A UX
1
O OO
+6
AUX
2
OO
+6
AUX AUX
3
OO OO
+6
AUX
4
OO OO
+6
POST PRE PRE PRE
AUX
5
OO
+6
AUX
6
OO
POST PRE
PAN
R
ODDLEVEN+6ODD
5
-10 10
-20
16
ON ON
TO
LR
(ST1+ST2)
11-12
0
-5 5
-10 10
-20
OO OO
16
ON
HF
HM
LM
LF
1
OO
+6
AUX
2
OO
+6
3
OO
+6
AUX
4
OO
+6
POST
AUX
5
OO
+6
AUX
6
OO
+6
POST PRE
BAL
R
L
EVEN
MUTE MUTE
PK!
PK!
PFL
PFL
0
-5
13-14
ON
HF
HM
LM
LF
AUX
AUX
AUX
AUX
AUX
BAL
5
-10 10
-20
OOOO
16
MATRIX
TO
LR
(ST3+ST4)
0
-5
-10
-20
16
GRP
1
5
GRP
2
10
GRP
3
GRP
4
L
R
LEVEL
EQ INEQ INEQ IN
1
OO
+6
2
OO
+6
AUX
1
3
OO
+6
4
OO
+6
POST
5
OO
PAN
+6
6
OO
+6
POST PRE
R
L
EVEN
ODD
MUTE
PK!
PFL
GRP
1
OOOO
GRP
2
GRP
3
GRP
4
L
R
LEVEL
+6
+6
OOOO
+6
OOOO
+6
+6
OOOO
+6
+6
MUTE
+6
OO OO
+6
+6
+6
OO OO
+6
+6
OO OO
+6
MUTE
AFLAFL
AUX
2
OO OO OO OO OO OO
+10
AFL
REV
GRP1 GRP2 TO LR
PAN
R
L
PK! PK! +6
0
SIG
1
MUTE
AFL AFL
AUX
3
+10
AFL
REV
TO LR
+10
AFL
REV
GRP3 GRP4 TO LR
PAN
RL
+6
0
SIG
2
MUTE
RL
PK! PK! +6
0
SIG
3
MUTE
AFL AFL AFL
MIC
IN
MONITOR
AUX
6
OO
L
PFL AFL
OO
PHONES
+10
2TRK TO LR
R
+16 +9 +6 +3
0
-3
-6
-9
-12
-16
-20
-30
POWER
+10
L-R 2TRK
+10
AFL
REV
GRP/AUX REVERSE
FRONT-OF-HOUSE
STAGE MONITOR
TALKBACK
TRIM
MAXMIN
OSC/NOISE
TRIM
PINK NOISE
1kHz OSC
2TRK/USB
MAX
MIN
ON
TB SELECT
L-R
GRP 1-4
AUX 1-2
AUX 3-4
AUX 5-6
PRESS TO TALK
AUX
4
PAN
AUX
5
+10
AFL
REV
TO LR
+10
AFL
REV
LR SUM
MONO
AFL/PFL
LISTEN WEDGE
M
L
R
+6
0
SIG
4
MUTE
OO
+10
PK! +6
0
SIG
5
L
MUTE
PK! +6
0
SIG
R
6
MUTE
AFL
GAIN
TO
GAIN
SIG
10
5
0
L-R
5
1-2
3-4
20
SIG
10
5
0
L-R
5
1-2
3-4
20
30 30 30
OO OO OO
SIG
10
5
0
L-R
5
10
5
0
5
10
5
0
5
10
5
0
5
10
5
0
5
10
5
0
5
10
5
0
5
1-2
3-4
20
10
20
30
10
20
30
10
20
30
10
20
30
10
20
30
10
20
30
OO OO OO OO OO OO
Allen & Heath 6 WZ
65
4
Introducing the MixWizard WZ4 14:4:2
The Allen & Heath MixWizard series of consoles includes several models. This user guide de­scribes the WZ414:4:2 4 group model. The 2 bus WZ412:2 and WZ416:2 consoles are de­scribed in separate publications. For further information on the MixWizard series please refer to the Allen & Heath web site.
ALLEN&HEATH
GAIN
HF
HM
LM
LF
AUX
1
AUX
2
AUX
3
AUX
4
AUX
5
AUX
6
PAN
PK!
SIG
L-R
1-2
3-4
ALLEN&HEATH
RETURN
L
R
LISTEN WEDGE
MATRIX OUT
A
B
MixWizard WZ414:4:2
+48V
+48V
PAD
PAD
(LINE)
(LINE)
0
0
0
30
30
40
40
20
20
20
GAIN
GAIN
50
50
- 10 10
6040
- 10 10
6040
- 10 10
HPF
HPF
HF
HF
3k
3k
4k
1k
4k
1k
1k
6k
700
6k
700
700
15k
500Hz
15k
500Hz
500Hz
HM
HM
180
180
250
70
250
70
70
400
45
400
45
45
1k
35Hz
1k
35Hz
35Hz
LM
LM
LF
LF
AUX AUX
1
1
+6
+6
OO
OO
OO
AUX
AUX
2
2
+6
+6
OO
OO
OO
AUX
AUX
3
3
OO
OO
OO
+6
+6
AUX
AUX
4
4
+6
+6
OO
OO
OO
POST
POST
PRE PRE PRE
AUX
AUX
5
5
+6
+6
OO
OO
OO
AUX
AUX
6
6
OO
OO
OO
+6 +6
POST
POST
PRE
PRE
PAN
PAN
LR
L
R
L
ODD
ODD
EVEN
EVEN
ODD
MUTE MUTE MUTE
PK!
PK!
PFL
PFL
SIG
SIG
10
10
10
5
5
5
0
0
0
L-R
L-R
5
5
5
1-2
1-2
3-4
3-4
20
20
20
30
30 30 3 0 30 30 30 30 30 30 30 30
OO OO OO OO OO OO OO OO OO OO OO OO OO OO OO OO OO OO
2-TRACK
SEND
INSERT
L
L
A5
OUT
R
M
OUT
INSERT
R
A6
MONITOR OUT
OUT
L
R
AUX 6
AUX 5 AUX 4 AUX 3 AUX 2 AUX 1
R L
SENDS 15/16
2 TRK SOURCE
LR INSERTS MATRIX
USB 2.0
MULTICHANNEL AUDIO
+48V
+48V
+48V
PAD
PAD
PAD
(LINE)
(LINE)
(LINE)
30
40
50
6040
HPF
3k
4k
6k
15k
180
250
400
1k
+6
+6
+6
+6
POST
+6
+6
POST PRE
R EVEN
PFL
INSERT
OUT
INSERT
OUT
G4
2 TRK RETURN USB RETURN
0
0
0
30
30
40
40
20
20
20
GAIN
GAIN
GAIN
50
50
- 10 10
6040
- 10 10
6040
- 10 10
HPF
HPF
HF
HF
HF
3k
3k
4k
1k
4k
1k
1k
6k
700
6k
700
700
15k
500Hz
15k
500Hz
500Hz
HM
HM
HM
180
180
250
70
250
70
70
400
45
400
45
45
1k
35Hz
1k
35Hz
35Hz
LM
LM
LM
LF
LF
LF
AUX AUX
AUX
1
1
1
+6
+6
OO
OO
OO
AUX
AUX
AUX
2
2
2
+6
+6
OO
OO
OO
AUX
AUX
AUX
3
3
3
OO
OO
OO
+6
+6
AUX
AUX
AUX
4
4
4
OOOOOOOOOOOOOOOOOOOOOO
+6
+6
OO
OO
OO
POST
POST PRE PRE PRE PRE PRE PRE
AUX
AUX
AUX
5
5
5
+6
+6
OO
OO
OO
AUX
AUX
AUX
6
6
6
OO
OO
OO
+6 +6
+6
POST
POST
PRE
PRE
PAN
PAN
PAN
L-R
1-2
3-4
3
A3
4
A4
R
L
ODD
EVENODD
MUTE MUTE MUTE
PK!
PK!
PFL PFL
SIG
SIG
10
5
0
L-R
5
1-2
3-4
20
INSERT
1
A1
OUT
INSERT
2
A2
OUT
G2G3 G1
LR
L
EVEN ODD
PK!
SIG
10
10
5
0
L-R
5
1-2
3-4
20
20
L/M
ST3
L/M
ST4
AUX SENDS
+48V
+48V
+48V
PAD
PAD
PAD
(LINE)
(LINE)
(LINE)
30
40
50
6040
HPF
3k
4k
6k
15k
180
250
400
1k
+6
+6
+6
+6
POST
+6
POST PRE
R EVEN
PFL
5
0
5
13-14
R
R
GRP/AUX REVERSE
0
0
0
30
30
40
40
20
20
20
GAIN
GAIN
GAIN
50
50
- 10 10
6040
- 10 10
6040
- 10 10
HPF
HPF
HF
HF
HF
3k
3k
4k
1k
4k
1k
1k
6k
700
6k
700
700
15k
500Hz
15k
500Hz
500Hz
HM
HM
HM
180
180
250
70
250
70
70
400
45
400
45
45
1k
35Hz
1k
35Hz
35Hz
LM
LM
LM
LF
LF
LF
AUX AUX
AUX
1
1
1
+6
+6
OO
OO
OO
AUX
AUX
AUX
2
2
2
+6
+6
OO
OO
OO
AUX
AUX
AUX
3
3
OO
OO
OO
+6
+6
AUX
AUX
AUX
4
434
+6
+6
OO
OO
OO
POST
POST
AUX
AUX
AUX
5
5
5
+6
+6
OO
OO
OO
OO
AUX
AUX
AUX
6
6
6
OO
OO
OO
+6 +6
+6
POST
POST
PRE
PRE
PAN
PAN
PAN
L
R EVEN
ODD
ODDLRODDLEVEN
MUTE MUTE MUTE
PK!
PK!
PK!
PFL
PFL
SIG
SIG
SIG
10
10
5
5
0
0
L-R
L-R
L-R
5
5
1-2
1-2
1-2
3-4
3-4
3-4
20
20
MixWizard WZ414:4:2
INSERT
11-12
10
L/M
ST1
LINE IN
R
10
MIC
L/M
ST2
R
DIRECT
OUT
XLR OUT
21
+OUT
3
- OUT
0
-5 5
GAIN
+48V
+48V
-10 10
-20
PAD
PAD
16
(LINE)
(LINE)
0
30
30
ON ON
40
40
20
GAIN
50
50
TO
LR
6040
- 10 10
6040
HPF
HPF
(ST1+ST2)
TO
11-12
0
-5
HF
5
GAIN
-10 10
-20
OO OO
3k
180
PFL
10
5
0
5
20
INSERT
LINE IN
9
MIC
DIRECT
OUT
16
3k
4k
4k
1k
ON
6k
6k
700
15k
15k
500Hz
HF
HM
180
HM
250
250
70
400
400
45
1k
1k
35Hz
LM
LM
LF
LF
AUX AUX AUX
1
1
O
+6
+6
+6
OO
OO
AUX
AUX
2
2
+6
+6
+6
OO
OO
AUX AUX
3
3
OO OO
OO
+6
+6
+6
AUX
AUX
4
4
+6
+6
+6
OO
OO
POST
POST
POST
PRE PRE PRE
AUX
AUX
5
5
+6
+6
+6
OO
OO
AUX
AUX
6
6
OO
OO
+6
POST
POST
POST
PRE
PRE
PRE
BAL
PAN
R
L
R
R
EVEN
ODDLEVEN+6ODD
EVEN
MUTE MUTE
PK!
PK!
PFL
PFL
SIG
SIG
10
10
5
5
0
0
L-R
L-R
5
5
1-2
1-2
3-4
3-4
20
20
9
INSERT
8
INSERT
LINE IN
LINE IN
8
7 6
MIC
MIC
DIRECT
DIRECT
OUT
OUT
910
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIREREPLACE FUSE WITH SAME TYPE AND RATING. ATTENTION: REMPLACER PAR UN FUSIBLE STRICTEMENT IDENTIQUE EN VALEURS.
Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan Apparatet må tilkoples jordet stikkontakt Apparaten skall anslutas till jordat uttag
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
0
-5 5
GAIN
-10 10
-20
OOOO
16
MATRIX
GRP
TO
LR
1
13-14
TO
(ST3+ST4)
0
-5 5
GAIN
GRP
-10
2
10
-20
16
GRP
ON
3
HF
GRP
4
HM
L
LM
R
LEVEL
LF
EQ INEQ INEQ INEQ INEQ INEQ INEQ INEQ INEQ INEQ INEQ INEQ IN
1
+6
OO
AUX
2
AUX
1
+6
OO
AUX
3
OO
+6
AUX
4
+6
OO
POST
AUX
5
PAN
+6
OO
AUX
6
OO
+6
POST PRE
BAL
R
L
EVEN
ODD
MUTE AFL AFL
PK!
PFL
SIG
10
10
5
50505050505
0
0
L-R
5
5
1-2
10
3-4
20
20
30
INSERT
7
6
INSERT
LINE IN
LINE IN
5
MIC
MIC
DIRECT
DIRECT
OUT
OUT
CONFORMS TO ANSI/UL STD. 60065-2003 CERTIFICATED TO CAN/CSA STD.60065-03
MADE IN CHINA
LAMP
GRP
1
+6
GRP
2
OO OO
+6
GRP
3
+6
GRP
4
+6
+6
OO OO
+6
LEVEL
+6
OO OO
MUTE
AUX
2
+10
OO OO OO OO OO OO
AFL
REV
GRP1 GRP2 TO LR
PAN
R
L
PK! PK! +6
0
SIG
1
MUTE
10
5
10
20
30
5
LINE IN
DIRECT
Serial No.ENGINEERED IN ENGLAND BY ALLEN & HEATH LIMITED
+6
OOOO
+6
+6
OOOO
+6
OOOO
L
+6
R
OOOO
+6
+6
MUTE
AFLAFL
AUX
3
+10
AFL
REV
TO LR
PAN
RL
+6 0 SIG
2
MUTE
10
5
10
20
30
INSERT
4
INSERT
LINE IN
4
MIC
DIRECT
OUT
FUSE
T630mA L 250V 20mm
WARNING: THIS APPARATUS MUST BE EARTHED
MIC
TALKBACK
TRIM
OSC/NOISE
TRIM
PINK NOISE
1kHz OSC
AUX
4
+10
AFL
AFL
REV
REV
GRP3 GRP4
TO LR
TO LR
PAN
L
RL
PK! PK!
+6
+6
0
0
SIG
SIG
4
3
MUTE
MUTE
AFL AFL AFL
10
5
10
20
30
INSERT
3
LINE IN
3
2
MIC
MIC
DIRECT
OUT
OUT
INSERT
SEND
RETURN
AC MAINS IN ~
100 - 240V~ 47-63Hz 45W MAX
CET APPAREIL DOIT ETRE MIS A LA TERRE
IN
ON
TB SELECT
L-R
GRP 1-4
AUX 1-2
AUX 3-4
AUX 5-6
PRESS TO TALK
+10
REV
LR SUM
AFL/PFL
LISTEN WEDGE
R
PK! +6
SIG
L
10
5
10
20
30
2
2 TIP
RING
TIP +INTIP RING -INRING
PHONES
MAXMIN
2TRK/USB
OO
+10
MAXLMIN
2TRK TO LR
R
+16 +9 +6 +3
0
-3
-6
-9
-12
-16
-20
-30
PFL
POWER
AFL
MONITOR
+10
OO
L-R 2TRK
AUX5AUX
6
+10
+10
AFL
AFL
REV
GRP/AUX REVERSE
FRONT-OF-HOUSE
MONO
STAGE MONITOR
M
+10
OO
PK! +6 0
0
SIG
R
6
5
MUTE
MUTE
AFL
10
5
10
20
30
65
INSERT
1
LINE IN
1
MIC
DIRECT
OUT 12345678
INPUT
+IN
1
MIC
- IN
3
LINE
ONI0OFF
The MixWizard is a compact console designed for professional sound mixing. It is built to the same high standards as our top of the range con­soles, with individual circuit cards, potentiome­ters nutted to the panel for absolute strength, steel chassis, and no compromise circuit design ensuring the finest sonic performance.
The console can be operated free standing or in a 19” rack or flightcase. It is supplied with pro­tective side trims fitted. These can be removed for rack mounting. The rear connector pod can be easily rotated for rear facing or underside connectors when rack mounted.
With its 4 band semi-parametric EQ, 4 groups, 6 auxes and stereo main output the WZ414:4:2 is equally at home mixing live shows, recordings and corporate events. Tamperproof recessed switches configure the console for optimum FOH or stage monitor operation. This ‘dual function­ality’, pioneered by Allen & Heath, gives the con­sole its unique ability to properly function as Front-of-House or stage monitor, or handle both at the same time, ideal as a hard working work horse for hire stock, touring and installed sound.
The WZ414:4:2 has 10 mono mic/line inputs, 2 fully featured dual input stereo channels and a 2­track replay input, a total of 20 inputs to the mix. Of special note is the addition of a 2 x 6 way matrix providing a useful multi-purpose output for those special demands such as recording and broadcast feeds, delay fills, zone feeds and so on. A host of top end features are provided including oscillator and pink noise generator, individual talkback to all outputs, comprehensive engineer’s metering and monitoring and a lamp socket.
The base of the console can be removed to ac­cess internal user selectable options. These con­figure user preference for the aux sends, direct outputs and talkback mic phantom power.
The aux and matrix outputs are impedance bal­anced but may be electronically balanced if re­quired by fitting an optional part. A kit is also available to fit an optional USB2 output card which allows the console to be linked to a com­puter for multitrack recording.
An Allen & Heath LEDlamp gooseneck lamp with built-in dimmer can also be added for lighting the console in low light conditions.
Allen & Heath 7 WZ
4
Installing the Console
Free Standing
The console is supplied ready for free standing operation with its side trims fitted and connector pod positioned for rear access. If you are converting from rack to free standing then make sure the pod is correctly rotated and se­cured, and the side trims fitted as shown:
19” Rack Mount
For rack mounting, remove the two side trims and rotate the pod into the connector position preferred. Allow enough space for the cables and connectors behind the console.
Do not transport the console with its connector pod securing screws removed. Do not attempt to re­move the connector pod from the console. Do not obstruct the ventilation slots. Allow adequate space around the console for air flow. If the side trims are to be removed, do not refit their fixing screws to the unit. Retain and store these in case the trims need to be refitted in the future.
Allen & Heath 8 WZ
4
Connecting Power
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
CAUTION: FOR CONTINUED PROTECTIO N AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
ATTENTION: REMPLACER PAR UN FUSIBL E STRICTEMENT IDENTIQUE EN VALEURS.
Laite on liitettävä suojamaado ituskoskettimilla varustettuun pistorasiaan Apparatet må tilkoples jordet stikkontakt Apparaten skall anslutas till jordat uttag
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Read and understand the Important Safety Instructions printed at the start of this guide, and the warnings printed on the rear of the console. Check that your local mains supply is within the 100-240V operating voltage range allowed. Check that the correct mains lead with moulded plug has been sup­plied with your console. Make sure that the IEC mains plug is pressed fully
into the panel socket before switching on.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CONFORMS TO ANSI/UL STD. 60065-2003
CERTIFICATED TO CAN/CSA STD.60065-03
MADE IN CHINA
Serial No.ENGINEERED IN ENGLAND BY ALLEN & HEATH LIMITED
FUSE
T630mA L 250V 20mm
WARNING: THIS APPARATUS MUST BE EARTHED
AC MAINS IN ~
100 - 240V~ 47-63Hz 45W MAX
CET APPAREIL DOIT ETRE MIS A LA TERRE
ONI0OFF
Grounding
The connection to ground in an audio system is important for two reasons:
1. SAFETY - To protect the operator from high voltage electric shock, and
2. AUDIO PERFORMANCE - To minimise the effect of ground (earth) loops which result in audible hum and buzz, and to shield the audio signals from interference.
3. For safety it is important that all equipment grounds are connected to mains ground so that exposed metal parts are prevented from carrying high voltage which can injure or even kill the operator. Do not disconnect the ground connection in the mains lead. It is recommended that the system engineer check the continuity of the safety ground from all points in the system including microphone bodies, turntable chassis, equipment cases, rack metalwork and so on.
Switching the console on and off
It is good practice to turn power amplifiers off before switching the console and any other con­nected equipment on or off. This prevents any unexpected clicks or thumps when the equip­ment is powered up.
Turn amplifiers and powered speakers on last and off first.
To turn the console on, press the ON/OFF switch next to the IEC mains input socket. To turn the console off, press this switch again.
Allen & Heath 9 WZ
4
Loading...
+ 19 hidden pages