Read this document and the documents listed in the additional resources section about installation, configuration, and
operation of this equipment before you install, configure, operate, or maintain this product. Users are required to
familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws,
and standards.
Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are
required to be carried out by suitably trained personnel in accordance with applicable code of practice.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may
be impaired.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from
the use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and
requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or
liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or
software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation,
Inc., is prohibited
Throughout this manual, when necessary, we use notes to make you aware of safety considerations.
WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous
environment, which may lead to personal injury or death, property damage, or economic loss.
ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property
damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence.
IMPORTANTIdentifies information that is critical for successful application and understanding of the product.
Labels may also be on or inside the equipment to provide specific precautions.
SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous
voltage may be present.
BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may
reach dangerous temperatures.
ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to
potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL
Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).
KVMKeyboard video mouseUPSUninterruptible power source
LANLocal area networkVBATVoltage (battery)
NEMA
National Electrical Manufacturers Association
ODD
Optical disk drive
OSK
On-screen keyboard
Protective capacitive (touch screen)
VDDRVoltage (DDR RAM)
VGAVideo graphics array
10Rockwell Automation Publication 6177R-UM002E-EN-P - March 2017
Features
Top icPa ge
Computer Overview11
Operating Systems11
Computer Options12
Before You Begin12
Parts List13
Hardware Features13
Chapter 1
Computer Overview
Operating Systems
Non-display industrial computers run operations from small visual interface
and maintenance applications to large control and information applications.
Combine an industrial display with the 750R (catalog number 6177R-MM) or
1450R (catalog number 6177R-RM) computer to complete your system.
These computers are available with performance, advanced, and server features.
They come standard with a selection of I/O ports for peripheral connections
and expansion slots.
The following Microsoft-licensed operating systems are available:
• Windows Embedded 8.1 Industry Pro (64-bit)
• Windows 7 Professional, Service Pack 1 (64-bit)
• Windows Server 2012 R2 Standard (64-bit)
• Windows Server 2008 R2 Standard, Service Pack 1(64-bit)
• Windows 10 IoT Enterprise (64 bit)
No operating system updates have been applied to the factory image beyond
the service packs.
Computers with HDDs include a recovery partition with the original factory
image. You can use AMI Rescue that is embedded in the BIOS/UEFI set-up
utility to restore the operating system from the recovery partition, and create a
recovery image. See AMI Rescue
on page 75 for instructions.
IMPORTANTComputers with the Windows Embedded 8.1 Industry Pro operating system
do not contain a backup of the factory image in the recovery partition.
Rockwell Automation Publication 6177R-UM002E-EN-P - March 201711
Chapter 1Fea tures
To obtain a copy of a factory system image, contact your local technical support
center or access the Rockwell Automation® Product Compatibility and
Download Center (PCDC) at http://www.rockwellautomation.com/
support/pcdc.page.
Computer Options
This table summarizes the options that are available for non-display industrial
computers. A comparative summary of features for the computers is in
Industrial Computers and Monitors Specifications Technical Data, publication
IC-TD001
Cat. No.ModelForm Fac torPack ageWindows O S
6177R-RMPW7 1450R4U rack mountPerformance7 Professional SP1
6177R-RMPWX10 IoT Enterprise
6177R-RMPNO None
6177R-RMRNO Redundant
6177R-RMAW7 Advanced7 Professional SP1
6177R-RMAW8Embedded 8.1 Industry Pro
6177R-RMAWX10 IoT Enterprise
6177R-RMSS8 ServerServer 2008 R2 Standard SP1
6177R-RMS12Server 2012 R2 Standard
6177R-RMSNO None
6177R-MMPW7 750RMachine mountPerformance7 Professional SP1
6177R-MMPWX10 IoT Enterprise
6177R-MMPNO None
6177R-MMAW8AdvancedEmbedded 8.1 Industry Pro
6177R-MMAWX10 IoT Enterprise
6177R-MMSS8 ServerServer 2008 R2 Standard SP1
6177R-MMS12Server 2012 R2 Standard
6177R-MMSNO None
(1) All operating systems are 64 bit.
.
(1)
Before You Begin
Before you unpack the computer, inspect the shipping carton for damage. If
damage is visible, immediately contact the shipper and request assistance.
Otherwise, continue to unpack.
Keep the original packing material in case you must return the computer for
repair or transport it to another location. Use both inner and outer packing
cartons to provide adequate protection for a computer that is returned for
service.
12Rockwell Automation Publication 6177R-UM002E-EN-P - March 2017
Featu resChapter 1
Parts List
Hardware Features
The computers ship with the following items.
ItemDescription
Hardware• Power cord for AC power models
•Mounting hardware
– Rack handles for 1450R computers
– Mounting brackets for 750R computers
– Mounting fasteners
– Cable ties for internal USB device
2Power status indicator7USB 2.0 ports, 212ODD eject button
3Disk drive access status indicator8Power switch13ODD mechanical eject hole
4System health status indicator9USB 3.0 por t14HDD SATA 0
5Door lock10ODD SATA 215HDD SATA 1
(1) Computers with Windows Server operating systems ship with two HDDs that are configured for RAID 1 operation. Computers that ship with two HDDs but no operating system are not configured for
RAID 1 operation.
(2) A second HDD is optional for computers with non-server operating systems.
1PS/2 mouse port7Gigabit LAN ports, 213USB 3.0 port
2Functional ground screw8Line-in jack14eSATAp port
3DVI-D2 port9Line-out jack15USB 2.0 ports, 4
4Serial COM2 port (RS-232)
5Serial COM1 port (RS-232)11PS/2 keyboard port17PCI expansion slot covers, 7
6Parallel port12DVI-I1 port
10Power input, AC16Microphone-in jack
Rockwell Automation Publication 6177R-UM002E-EN-P - March 201715
Chapter 1Fea tures
750R-Front Panel
1450R-Front Panel
321
Status Indicators
There are three status indicators on the front panel of the 750R and 1450R
computers. These indicators aid in issue diagnosis by providing status
information of different system components.
ItemIconIndic atorStatusDescription
1Power statusGreenThe computer is operating.
Flashing orangeThe computer is in standby mode.
OffThe computer is off.
2Disk drive access statusFlashing redHDD or ODD activity.
OffNo HDD or ODD activity.
3System health statusRedThe computer temperature threshold has been exceeded.
OffSystem health is normal.
16Rockwell Automation Publication 6177R-UM002E-EN-P - March 2017
Featu resChapter 1
4
2
1
12
16
11
3
5
7
17
69
810
18
13
19
14
15
202122232425
26
27
28
29
30
32
31
33
34
35
36
System Boards
The illustrations in this section show the system board layouts for the
computers. The 750R and 1450R computers share system boards except for
the PCI expansion board, which is available only on 1450R computers.
Figure 5 - Motherboard
ItemComponentItemComponentItemComponent
1PCI expansion board connector13Rear USB 3.0 port 25Battery socket
2Clear UEFI (CMOS1) jumper14DVI-D2 connector26Serial port (COM1)
3Platform control hub15PS/2 keyboard port27Internal parallel connector
4PCI expansion slot16Gigabit LAN 2 port28Serial port (COM2)
1PCI expansion board power connector3PCI expansion slots
2Motherboard connector
18Rockwell Automation Publication 6177R-UM002E-EN-P - March 2017
Install the Computer
Top icPa ge
Installation Precautions20
Installation Guidelines21
Mounting Clearance Requirements22
Mounting Hardware22
Computer Dimensions23
Required Tools23
Install the Computer24
Connect Per ipherals2 7
Connect Powe r29
Functional Ground Screw29
Connect to a Network30
Chapter 2
Rockwell Automation Publication 6177R-UM002E-EN-P - March 201719
Chapter 2Install the Computer
Installation Precautions
Read and follow these precautions before you install the computer.
Environment and Enclosure Information
ATT EN TI ON : This equipment is intended for use in a Pollution Degree 2
industrial environment, in overvoltage Category II applications (as defined in
IEC 60664-1), at altitudes up to 2000 m (6561 ft) without derating.
This equipment is considered Group 1, Class A industrial equipment according to
IEC/CISPR 22. Without appropriate precautions, there can be potential
difficulties with electromagnetic compatibility in other environments due to
conducted and radiated disturbance.
This equipment is supplied as open type equipment. The interior of the
enclosure must be accessible only by the use of a tool. UL Listed equipment need
not be mounted inside another enclosure. Subsequent sections of this
publication can contain extra information about specific enclosure type ratings
that are required to comply with certain product safety certifications.
In addition to this publication, see the following:
• Industrial Automation Wiring and Grounding Guidelines, publication 1770-
4.1, for additional installation requirements
• NEMA 250 and IEC 60529, as applicable, for explanations of the degrees of
protection that are provided by different types of enclosure
European Union Directive
This computer meets the European Union Directive requirements when
installed within the European Union or EEA regions and have the CE mark. A
copy of the
http://www.rockwellautomation.com/certification
declaration of the conformity is available at
.
ATT EN TI ON : This computer is intended to operate in an industrial or control
room environment, which uses some form of power isolation from the public
low–voltage mains. Some computer configurations cannot comply with the
EN 61000-3-2 Harmonic Emissions standard as specified by the EMC
Directive of the European Union. Obtain permission from the local power
authority before you connect any computer configuration that draws more
than 75 W of AC power directly from the public mains.
To comply with EN 55024, the Ethernet port LAN cable must be only used
indoors. All other I/O cables must be less than 3 m (9.84 ft) and only used
indoors.
20Rockwell Automation Publication 6177R-UM002E-EN-P - March 2017
Install the ComputerChapter 2
Installation Guidelines
Follow these guidelines to make sure that your computer provides service with
excellent reliability:
• The installation site must have sufficient power.
ATTENTION: To maintain an electrically safe installation, AC
powered computers must be plugged into a grounded outlet.
• In dry environments, static charges can build up easily. A properly
grounded computer helps to reduce static discharges, which can cause
shock and damage electronic components.
• The enclosure must allow sufficient space around air inlets and outlets to
provide the circulation necessary for cooling. See Mounting Clearance
Requirements on page 22 for further information. Never allow air
passages to become obstructed.
•The ambient air temperature must not exceed the maximum operating
temperature of 0…50° C (32…113° F). Consider a user-supplied fan,
heat exchanger, or air conditioner for heat from other devices in the
enclosure.
TIPHot air rises. The temperature at the top of the enclosure is often
higher than the temperature in other parts of the enclosure,
especially when air does not circulate.
IMPORTANTThe computer can operate at a range of extremes. However, the life
span of the computer is shortened if you continuously operate it at
its highest rated temperature, which includes the touch screen and
LCD panel.
• The humidity of the ambient air must not exceed 10…90% and must
avoid condensation.
• The enclosure or cover must always remain in place during operation.
The cover provides protection against high voltages inside the computer
and inhibits radio-frequency emissions that can interfere with other
equipment.
Rockwell Automation Publication 6177R-UM002E-EN-P - March 201721
Chapter 2Install the Computer
Mounting Clearance
Requirements
Mounting Hardware
When selecting an installation site for the computers, allow a minimum of
76 mm (3 in.) clearance at the front and rear of the computer for adequate
ventilation and cable connections.
IMPORTANTComputers generate heat. Therefore, do not operate the computer in an
enclosure with the minimum clearances unless adequate ventilation or
other methods are used to lower the temperature within the enclosure.
Allow enough clearance to install or remove peripheral components, such as
storage drives.
The table lists the hardware that is required for each type of installation.
22Rockwell Automation Publication 6177R-UM002E-EN-P - March 2017
Install the ComputerChapter 2
360
(14.2)
170
(6.7)
381 (15)
750R Computers1450R Computers
Front View
Front View
Side View
Top Vie w
465
(18.3)
176
(6.9)
Computer Dimensions
Review computer dimensions to estimate the clearance necessary for computer
installation. Dimensions are given in mm (in.).
Required Tools
These tools are required for computer installation:
• #2 cross-head screwdriver
• Slot-head screwdriver
• Drill motor and drill bit
• Antistatic wriststrap
Rockwell Automation Publication 6177R-UM002E-EN-P - March 201723
Chapter 2Install the Computer
Bottom Mounting BracketsSide Mounting Brackets
Install the Computer
The computers support the following mounting options:
• Machine or wall mount (for 750R models)
• Rack mount (for 1450R models)
Mount the 750R Computer
You can mount the 750R computer on any flat surface, such as a shelf inside a
machine or against a wall, by using mounting brackets. Holes are provided on
both sides of the 750R computer for side mounting installation.
TIPFor ease of installation, use two or more people to install the computer.
Follow these steps to mount the 750R computer.
1. Verify that the mounting location provides adequate space for cables and
airflow.
See Mounting Clearance Requirements
allowances.
2. Decide where to locate the mounting brackets (the bottom side for an
upright installation or the side for a wall installation).
on page 22 for recommended
3. Attach each mounting bracket to the computer with four screws.
Torque the screws to 1.3 N•m (12.1 lb•in).
24Rockwell Automation Publication 6177R-UM002E-EN-P - March 2017
Bottom Mounting Bracket Hole Locations
Dimensions are in mm (in.).
IMPORTANT: Bottom view is enlarged
for detail and not in scale to front view.
120 (4.73)120 (4.73)120 (4.73)
24 (0.95) x 4
382.1 (15.04)
60 (2.36)
240 (9.45)
210
(8.27)
194
(7.64)
70.5 (2.78)
375
(14.76)
360
(14.17)
A
B
Side Mounting Bracket Hole Locations
120 (4.73)
120 (4.73)120 (4.73)
382.1 (15.04)
60 (2.36)
240 (9.45)
401.6
(15.81)
385.6
(15.18)
70.5 (2.78)
185 (7.28)
175 (6.89)
Mounting Hole Details (all brackets)
Install the ComputerChapter 2
4. See Figure 9 to decide which mounting holes to use on the bracket.
5. Drill holes in the wall or shelf to accommodate screws sized M6…M8.
Figure 9 - Mounting Hole Locations on 750R Computers
CalloutDim, mm (in.) QtyDescription
AØ 10 (0.39)4Use these mounting holes for the following.
BØ 6.5 (0.25)8Use these mounting holes when shock and vibration are environmental
• You are replacing a legacy computer.
•Shock and vibration are not environmental elements.
elements.
6. Fasten the computer to the wall or shelf with M6…M8 mounting screws.
Rockwell Automation Publication 6177R-UM002E-EN-P - March 201725
Chapter 2Install the Computer
Mount the 1450R Computer in a Rack Cabinet
You can install the 1450R computer in a rack cabinet that does the following:
• Conforms to EIA standards for equipment with 483 mm (19 in.) wide
panels
• Accommodates the 4U height and depth of the computer
• Provides rear clearance for cables and airflow
A rack cabinet with a depth of 610 mm (24 in.) is sufficient.
IMPORTANT
Rack slides are not supplied with the computer and must be ordered
separately.
See Mounting Hardware on page 22 for the catalog number necessary for
ordering.
See Install Rack Slides (1450R Computer) on page 96
if you have purchased
the rack slides.
Support the computer with rack slides or by fastening it to a shelf. The four
flanges of the computer secure the computer horizontally only to the front
mounting rails of the rack cabinet.
TIPFor ease of installation, use two or more people to install the computer.
Follow these steps to mount the 1450R computer.
1. Verify that the mounting location provides adequate space for cables and
airflow.
See Mounting Clearance Requirements
on page 22 for recommended
allowances.
2. Attach the supplied rack handles to the computer.
Torque the screws to 1.3 N•m (12.1 lb•in).
3. See Install Rack Slides (1450R Computer)
rack slides to the rack cabinet and the 1450R computer.
26Rockwell Automation Publication 6177R-UM002E-EN-P - March 2017
on page 96 on how to install
Install the ComputerChapter 2
Connect Peripherals
The following illustration shows the I/O port panel of the computers.
Peripheral components compatible to each port are inside the callout figures.
Figure 10 - 750R and 1450R Computer Peripherals
TIP• There are three USB ports on the front panel. Use these ports to connect
various USB devices to the computer, such as an external drive.
• You can use a DVI-to-VGA adapter to connect an external VGA display to
the DVI-I1 port of the computer.
Rockwell Automation Publication 6177R-UM002E-EN-P - March 201727
Chapter 2Install the Computer
Internal USB port secured with factory installed cable tie.
An activation dongle that is connected to internal USB port and secured with the supplied cable ties.
Internal USB Port
There is an internal USB port for activation dongles or other USB storage
devices. You must first remove the computer cover to access the port.
See Chapter 4
for how to remove and reinstall the computer cover.
TIPTo connect an external device, cut the factory installed cable tie that secures
the internal USB port.
We recommend that you fasten any device that is connected to the internal
USB port with the supplied cable ties.
28Rockwell Automation Publication 6177R-UM002E-EN-P - March 2017
Install the ComputerChapter 2
Connect Power
A grounded, 3-prong IEC60320-C13 power cord provides power to the
computer. The power supply input accepts 100…240V AC and is autoranging.
ATT EN TI ON : When you connect power to the computer for the first time, the
following actions occur:
• The default UEFI setting automatically starts the computer after it is plugged
into a power source.
• You must read and accept an End User Setup procedure for computers with a
Windows operating system (requires an external display).
Do not disconnect power from the system until after the Windows Setup
procedure is completed. If power is disconnected during this procedure, it
can result in a corrupted system image.
Operate the computer in an industrial or control room environment, which
uses some form of power isolation from the public low-voltage mains.
ATT EN TI ON : Supply the computer circuit with its own disconnect. Use an
uninterruptible power source (UPS) to help protect against unexpected
power failure or power surges.
Always shut down the Windows operating system before you disconnect power
to the computer to minimize performance degradation and operating system
failures.
Functional Ground Screw
Follow these steps to connect the computer to an AC power source.
1. Connect the power cord to the AC power input. See Hardware Features
starting on page 13
for where the power inputs are on each computer
model.
2. Connect the AC power cord to a power source.
SHOCK HAZARD: Connect the AC power cord to a power source with
an earth ground. Failure to follow this warning can result in electrical
shock.
3. Apply 100…240V AC power to the computer.
The pre-installed functional ground screw is not required for safety or
regulatory compliance. If a supplemental ground is desired, use the functional
ground screw on the rear panel of the 750R and 1450R computers. See pages
14
and 15 for where the functional ground screw is on each computer model.
If you use the functional ground screw, connect the computer to earth ground
by using a 1.5 mm
2
(16 AWG) or larger external wire. Use a ground wire with
an insulation color that is approved by the local inspection authority.
Rockwell Automation Publication 6177R-UM002E-EN-P - March 201729
Chapter 2Install the Computer
Connect to a Network
The computers have two 1 Gb LAN ports that connect to an Ethernet
network by using CAT5 or CAT5e twisted-pair Ethernet cable with RJ45
connectors. See Hardware Features
ports are on each computer model.
IMPORTANTTo help prevent performance degradation of Ethernet communication, do
not subject the computer or cables to extreme radiation or conducted
high-frequency noise.
In industrial environments, proper cable routing and power conditioning are
required for Ethernet communication. We recommend that you route all
Ethernet cabling through dedicated metal conduits. For improved
performance reliability, install ferrite bead filters at the cable ends.
starting on page 13 for where the LAN
30Rockwell Automation Publication 6177R-UM002E-EN-P - March 2017
Loading...
+ 74 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.