Allen-Bradley 440G-LZS21SJRJ, 440G-LZS21SPLA, 440G-LZS21SJLJ, 440G-LZ, 440G-LZS21SPLB Installation Instructions Manual

...
Installation Instructions
Locking b olt
Actu ator
Switch body
Actuator mounting
bracket
QR Code
Alignment
guide
Original Instructions
440G-LZ Guard Locking Safety Switch
Catalog Numbers
440G-LZS21SJLJ, 440G-LZS21SJRJ, 440G-LZS21SPLA, 440G-LZS21SPLB, 440G-LZS21SPLH, 440G-LZS21SPRA, 440G-LZS21SPRB, 440G-LZS21SPRH, 440G-LZS21STLA, 440G-LZS21STLB, 440G-LZS21STLH, 440G-LZS21STRA, 440G-LZS21STRB, 440G-LZS21STRH, 440G-LZS21UJLJ, 440G-LZS21UJRJ, 440G-LZS21UPLA, 440G-LZS21UPLB, 440G-LZS21UPLH, 440G-LZS21UPRA, 440G-LZS21UPRB, 440G-LZS21UPRH, 440G-LZS21UTLA, 440G-LZS21UTLB, 440G-LZS21UTLH, 440G-LZS21UTRA, 440G-LZS21UTRB, 440G-LZS21UTRH
Additional Resources
ATT EN TI ON : Read this document and the documents that are listed
in the Additional Resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions, and requirements of all applicable codes, laws, and standards.
Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Topi c Page
Summary of Changes 1
Additional Resources 1
Introduction 1
Mounting 2
Installation Considerations 2
Auxiliary/Manual Release 3
Connections 4
The QR code on the switch provides a link to publication 440G-UM001A-EN-P.
Resource Description
440G-LZ Guard Locking Switch User Manual, publication 440G-UM001A-EN-P
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1
Product Certifications website, http://
www.rockwellautomation.com/products/ certification
You can view or download publications at http://
www.rockwellautomation.com/literature/. To order paper copies of
technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
Provides general guidelines for installing a Rockwell Automation guard locking switch.
Provides general guidelines for installing a Rockwell Automation industrial system.
Provides declarations of conformity, certificates, and other certification details.
Introduction
ATT EN TI ON : Do not attempt to install this device unless the
installation instructions have b een studied and u nderstood. This document acts as a guide for a typical installation and is available in some languages at Select the publication language and type 440G-LZ in the search field. A user manual is also available, publication
440G-UM001A-EN-P
www.rockwellautomation.com/literature.
.
Added required minimum distance between switches and detail for 5­pin quick-disconnect models.
Figure 1 - Assembly Overview
440G-LZ Guard Locking Safety Switch
For proper installation, a minimum of two fasteners must be used, at least one of which must be fitted to the top row of holes, closest to the bend in the actuator mounting bracket.
2 x M5/M6 CSK
3 x M5
The locking bolt must always enter the actuator mounting bracket first.
200 mm (7.87 in.) minimum
Align the white triangles
0.4 N•m
2 x T10
Torx screws
This 440G-LZ Guard Locking switch is for use on guards that are engineered to be rigid without sag. A separately mounted latch (for example, magnetic, mechanical) and mechanical stop is required.
Installation must be in accordance with these instructions and must be carried out by qualified personnel.
ATT EN TI ON : After installation, ensu re that there is no p ossibility of lifting the ac tuator over the extended locki ng bolt. Adherence to the recommended maintenance instructions forms part of the warr anty.
This device is intended to be part of the safety-related control system of a machine. Before installation, a risk assessment must be performed to determine whether the specifications of this de vice are suitable for all foresee able ope rational and environmental characteristi cs of the application. See Specifications on page 5 and ratings.
Use appropriate screws, bolts, or nuts that are fitted by tools to mount the switch and actuators to avoid the risk of tampering. Do not over torque the mounting hardware.
for certification information
Mounting
Figure 2 - Switch Body and Actuator
Installation Considerations
Figure 4 - Orientation of Assembled S
Minimum Distance Between Switches
If a pair of 440G-LZ switches is mounted close to each other, the two inductive fields interact causing crosstalk, which results in nuisance faults and false operation.
An absolute minimum of 200 mm (8 in.) must be used to help achieve correct operation.
The restriction applies if a 440G-LZ switch is mounted close to the TLS-Z guard locking and the 440N-Z SensaGuard™ switches.
Figure 5 - Minimum Distance between Switches
witch
ATT EN TI ON : For the switch, actuator and actuator mounting
bracket:
• Only use the designated mounting holes.
• Never drill or use to support other structures such as conduit, cable wa ys, or other hardware.
Figure 3 - Actuator Mounting Possibilities
2 Rockwell Automation Publication 440G-IN011B-EN-P - October 2018
Figure 6 -
Four Directions of Approach