Allen-Bradley 440G-EZ Installation Manual

Installation Instructions
260 (10.24)
260
(10.24)
Original Instructions
440G-EZ Interlocking Safety Switch
Catalog Numbers 440G-EZS21STL05J, 440G-EZS21STL05H
ATTENTION: Read this document and the documents that are listed in Additional Resources on page 4 about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions, and requirements of all applicable codes, laws, and standards. Only suitably trained personnel must perform activities including installation, adjustments, commissioning, use, assembly, disassembly, and maintenance in accordance with applicable code of practice.
If this equipment is used in a manner that the manufacturer does not specify, the protection that is provided by the equipment may be impaired.

Summary of Changes

This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes.
Top ic Pa ge
Updated Figure 3 Replaced Table 2 Added IP69K to enclosure ingress rating in Specifications table. 3
table. 2 .3

Installation

Adherence to the recommended maintenance instructions forms part of the warranty.
ATTENTION: The presence of spare actuators can compromise the integrity of the safety systems. Personal injury or death, property damage, or economic loss can result. Appropriate management controls, working procedures, and alternative protective measures should be introduced to control their use and availability.

Intended Use

The 440G electromagnetic switch is suitable for monitoring the position of guard doors. It has a magnetic locking device for process protection only.
ATTENTION: Locking force is not monitored. Locking force is not a safety-related function.

Mount Multiple Safety Switches

IMPORTANT
Figure 1 - Spacing Requirement [mm (in.)]
When several safety switches are mounted, the minimum distance between the individual systems must be followed to avoid mutual interference.

Mounting

The sensor can be mounted in the following ways:
Surface mount — The sensor is mounted on the fixed part of the protective device (for example, door frame).
Flush mount — The sensor is mounted in the fixed part of the protective device (for example, door frame). There must be a suitable recess in the mounting surface. The thickness of the mounting surface must be between 1.5…3 mm (0.06…0.12 in.)
For recess dimensions for flush mounting, see Figure 4 on page 4
IMPORTANT
Install the safety switch horizontally to help increase protection against manipulation.
.
WAR N IN G : Do not defeat, tamper, remove, or bypass this unit. Severe injury to personnel could result. This device must be provided with a 24V DC PELV or SELV power supply that conforms to the requirements of 414-3 of IEC 60364-4-41 where provisions have been taken to confirm that, even if an internal fault is present, the voltage at the outgoing terminals cannot exceed 60V DC. Improper selection or installation of the devices affects the integrity of the safety systems.
440G-EZ Interlocking Safety Switch Installation Instructions
Tightening torque:
1 N•m (8.9 lb•in)
Tightening torque:
1 N•m (8.9 lb•in)
43
8
2
3
4
1
6
75

Mount the Sensor

1. Unscrew the fixing screw (hexagon socket, 2 mm [0.08 in.]) and remove the cover plate.
2. Mount the sensor on the fixed part of the protective device with 4 x M4 screws and secure it with four nuts.
• For surface mount: mount the sensor on the fixed part of the
protective device. The screws can be set in the front or the back.

Mount the Actuator

1. Align the actuator to the mounted sensor.
2. Mount the actuator on the moving part of the protective device (for example, door) with 4 x M4 screws. Tightening torque: 1 N•m (8.9 lb•in). Use disposable screws if possible.
• Maximum angle between sensor and actuator when protective device
is closed: 3°
≤3°
3. Cover drill holes of the actuator with protective caps.

Wiring

Figure 2 - Device Connection Pin Assignment (Male Connector, M12, 5-pin, A-coded)
12
5
(1)
Pin
Wire Color
1Brown +24V DC
2 White OSSD 1
3 Blue 0V
4 Black OSSD 2
5 Gray Magnet
(1) Applies to the extension cables recommended as accessories.
Designation Description
Safety switch voltage supply
Safety output
0V DC voltage supply
Safety output
Magnet activation 24V DC
IMPORTANT
Pay attention to tightness of the plug connector.
Figure 3 - Device Connection Pin Assignment (Male Connector, M12, 8-pin, A-coded)
• For flush mount: mount the sensor in the fixed part of the protective device.
(1)
Pin
Wire Color
1White Aux
2 Brown +24V DC
3 Green Magnet
4 Yellow OSSD IN2
5Gray OSSD 1
6 Pink OSSD 2
7 Blue 0V
8 Red OSSD IN1
(1) Applies to the extension cables recommended as accessories. (2) When used as an individual safety switch or as the first safety switch in a cascade apply 24V DC.
3. Set cover plate on the sensor.
4. Tighten the fixing screws to 1 N•m (8.9 lb•in).
2 Rockwell Automation Publication 440G-IN019C-EN-P - November 2020
IMPORTANT
Designation Description
Application diagnostic output (not safe)
Safety switch voltage supply
Magnet activation 24V DC
Safety input
Safety output
Safety output
0V DC voltage supply
Safety input
(2)
(2)
Pay attention to tightness of the plug connector.
440G-EZ Interlocking Safety Switch Installation Instructions
12

Status Indicators

The switch has two status indicators:
Table 1 - Status Indicator States
Item Name Color Description
1 OSSD Green/Red
2 LOCK Yellow Turns ON when the magnet is supplied with voltage.
(1) When a load is applied to the application diagnostic output that is too high, the red OSSD status
indicator remains continuously ON. The actual switching behavior of the safety switch is not affected.
• Green when the OSSD pair is in the ON state.
• Red when the OSSD pair is in the OFF state.
(1)
Table 2 - Switch Status During Normal Operation
Door/Guard
Pins
8-pin
5-pin
(1) OSSD input only available for use with 8-pin version. (2) The AUX output and OSSD outputs are OFF if the device is in a fault state.
Status
Open On or Off Red Off Off
Closed On Green
Open Off Red Off Off
Closed Off Red Off Off
Open Red Off
Closed Green
OSSD Inputs
(1)
OSSD Indicator AUX Status OSSD Outputs
(2)
On
(2)
On
(2)
On

Maintenance

Frequency Description
• Ensure the alignment of the actuator to the switch and the correct operation
Every week
At least every 6months
of the switching circuit.
• Check for signs of abuse or interference.
• Inspect the switch casing and actuator for damage and replace if needed.
• Isolate all power.
• Remove the lid and end cover.
• Inspect all terminals for tightness.
• Clean out any accumulation of fine dirt.
• Check for any sign of wear of damage, for instance, actuator wear, cam assembly wear, contact oxidization and replace if needed.
• Replace cover and tighten screws to specified settings.
• Reinstate the power and check for correct operation.
• Reapply tamper evident varnish or similar compound for mountings.

Repair

If there is any malfunction or damage, make no attempts at repair. Replace before machine operation is allowed.
IMPORTANT
Do not dismantle the unit.

Specifications

Attribute 440G-EZS21STL05J, 440G-EZS21STL05H
Functional Safety Data (Guard door sensing)
Operating Characteristics
Safe switch on distance 4 mm (0.16 in.) Typical switch on distance 15 mm (0.59 in.) Safe switch off distance 45 mm (1.77 in.) Holding force 500 N Retaining force 25 N Maximum actuation frequency 0.5 Hz
Alignment tolerance for locking device
Aperture angle 3° Offset tolerance 5 mm (0.2 in.) Rated voltage 24V DC Insulation voltage U
Rated impulse withstand voltage U Supply voltage when an individual
safety switch is connected Supply voltage UV when a cascade is
connected
Power consumption
Switching frequency ≤0.5 Hz Type of output OSSD Maximum Output current ≤100 mA Diagnostic output ≤25 mA, short-circuit protected Cable capacitance 400 nF (for OUT A and OUT B) Response time 50 ms Enable time 100 ms Risk time 100 ms Power up delay 2.5 s Muting time when supply voltage is
interrupted
Environmental
Operating temperature -20…+55 °C (-4…+131 °F) Storage temperature -25…+70 °C (-13…+158 °F) Relative humidity 50% at 70 °C (158 °F) (IEC 60947-5-2) Enclosure ingress rating IP67, IP69K EMC IEC EMC: EN IEC 61326-3-1, EN IEC 60947-5-2, EN IEC 60947-5-3 Vibration resistance 1 mm/10…55 Hz (IEC 60068-2-6) Shock resistance 30 g, 11 ms (IEC 60068-2-27)
Outputs
Safety outputs
Auxiliary output 25 mA max, short-circuit protected (resistive load)
Switching voltage
Switching current
Test pulse du ratio n 300 µs
Weig ht
Sensor 510 g (18 oz) Actuator 210 g (7.4 oz)
Material
Sensor housing Anodized aluminum Actuator housing Fiberglass-reinforced PVC Anchor plate Nickel-plated steel
i
• PFHd= 1.5 x 10 sea level
•Mission time/PTI: 20 years
•Vertical: 5 mm (0.2 in.)
• Horizontal: 5 mm (0.2 in.)
32V
1.5 kV
imp
24V DC (19.2…28.8 V DC) Class 2 supply
• Sensor: 24V DC (22.8…28.8 V DC) Class 2 supply
• Magnet: 24V DC (21.6…28.8 V DC) Class 2 supply
• Locking active: 350 mA
• Locking deactivated: 50 mA
4 ms
2 x OSSDs, 2 x PNP, max 100 mA, short-circuit protected and overload-proof
• ON State: 19.2…28.8 V DC
•OFF State: 0…2 V DC
•ON State: ≤100 mA
•OFF State: ≤500 µA
-8
at 40 °C (104 °F) and 1000 m (3280.8 ft) above
Rockwell Automation Publication 440G-IN019C-EN-P - November 2020 3

Approximate Dimensions

44
(1.73)
44 (1.73)
14.4 (0.57)
14.4
(0.57)
15.2
(0.60)
22
(0.87)
22
(0.87)
28
(1.10)
16.3 (0.64)
83.5 (3.29)
32 (1.26)
Ø5 (0.20) x 4
Ø42
(1.65)
120 (4.72)
16.8
(0.66)
16.8
(0.66)
44 (1.73)
60
(2.36)
44
(1.73)
32
(1.26)
4 x
4.5 (0.18)
122 (4.8)
42
(1.65)
14.5
(0.57)
6.5
(0.26)
4.5
(0.18)
44
(1.73)
34
(1.34)
24
(0.94)
5.5
(0.22)
10
(0.39)
60
(2.36)
44
(1.73)
120 (4.73)
5.7
(0.22)
L
12.5
(0.49)
(1)
Figure 4 - Flush Mounting [mm (in.)]
Figure 6 - Sensor [mm (in.)]
Figure 5 - Actuator [mm (in.)]
(1) L = 150±2 mm (5.91±0.79 in.)

Additional Resources

These documents contain additional information concerning related products from Rockwell Automation.
Resource Description
440G-EZ Interlocking Safety Switch User Manual, publication 440G-UM003
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1
Product Certifications website:
rok.auto/certifications
You can view or download publications at rok.auto/literature.
Provides information that is needed during the lifecycle of the 440G-EZ safety switch.
Provides general guidelines for installing a Rockwell Automation industrial system.
Provides declarations of conformity, certificates, and other certification details.
Waste Electrical and Electronic Equipment (WEEE)
At the end of life, this equipment should be collected separately from any unsorted municipal waste.
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback.
For technical support, visit rok.auto/support.
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur
Allen-Bradley, expanding human possibility, Guardmaster, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 440G-IN019C-EN-P - November 2020 | Supersedes Publication 440G-IN019B-EN-P- June 2020
Copyright © 2020 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
10005248682 Ver 02
8025119/19G3/2020-11-03
Loading...