Allen-Bradley 42EF-C2KBA-F4, 42EF-P2MPB-F4, 42EF-B1MPBE-F4, 92-39, 92-113 Installation Manual

Page 1
Installation Instructions
RightSightt PHOTOSWITCH
Polarized Retrore-
Description
Sensing Distance 3m(9.8ft) 4.5 m (14.7 ft) 500 mm (20 in.) <127 mm (5 in.) 50 mm (2 in.) 100mm(4in.) Varies w/FO cable 20 m (60 ft) 4m(13ft)
Field of View 7 2.5 5 7 20 8 Varies w/FO cable 7 7
Transmitted LED Visible Red 660 nm Visible Red 660 nm Infrared 880 nm
Optical
Sensitivity Adjustment no no yes no yes no
Housing/Lens Material Specially formulated polymer/Acrylic
Connection Type Connection Type
LED Indicators See table below
Supplied Accessories One 18 mm mounting nut, two on fiber opti c models
Mechanical
Optional Accessories See accessories for mounting brackets, reflectors, apertures,fiber optic cables, cordsets,and patchcords
Operating Temperature
Operating Environment NEMA 3R, 4X, 6P, IP67;8270 kPa (1200 psi) washdown
Vibration/Shock 5g, 10-55 Hz, 1 mm amplitude, mee ts or exceeds IEC 947-5-2/30g, 1 ms pulse dur ation, meets or exceeds IEC 947-5-2
Relative Humidity 95%
Environmental
Certifications UL, CSA, CE for all applicable directiv es
CatalogNumber
Complementary LO & DO NPN
Complementary LO & DO PNP 42EF-P2MPB-a 42EF-D1MPAK-a 42EF-S1MPA-a 42E F-B1MPBC-a 42EF-B1MPBE-a 42EF-G1MPA-a 42EF-R9MPB-a 42EF-R9MPBV-a
DO NPN & PNP 42EF-P2KBB-a 42EF-U2KBB-a 42EF-D1KBAK-a 42EF-S1KBA-a 42EF-B1KBBC-a 42EF-B1KBBE-a 42EF-G1KBA -a 42EF-R9KBB-a 42 EF-R9KBBV-a
DC Sensors
LO NPN & PNP 42EF-P2JBB-a 42EF-U2JBB-a 42EF-D 1JBAK-a 42EF-S1JBA-a 42EF-B1JBBC-a 42EF-B1JBBE-a 42EF-G1JBA-a 42E F-R9JBB-a 42EF-R9JBBV-a
Voltage/Current/Power Consumption 10.8 to 30V DC @ 35 mA maximum (1 W maximum)
Sensor Protection Input reverse polarity, over voltage, false pulseprotected, output short-circuit(SCP) to 100 mA, overload
Output Type NPN, PNP, Dual NPN and PNP
Output Rating 30V DC @ 100 mA maximum (SCP prot ected)
DC Sensors
Output Leakage Current 0.1mA maximum
Response Time 1 ms typical, 4 ms for transmitted beam models
CatalogNumber
MOSFET, Dark operateoutput
MOSFET, Light operate output 42EF-P2RCB-b 42EF-U2RCB-b 42EF-D1RCAK-b 42EF-S1RCA-b 42EF-B1RCBC-b 42EF-B1RCBE-b 42EF-G1RCA-b 42EF-R9R CB-b 42EF-R9RCBV-b
MOSFET, Dark operateoutput 42EF-P2SFB-b 42EF-U2SFB-b 42EF-D1SFAK-b 42EF-S1SFA-b 42EF-B1SFBC-b 42EF-B1SFBE-b 42EF-G1SFA-b 42EF-R9SFB-b 42EF-R9SFBV-b
MOSFET, Light operate output 42EF-P2RFB-b 42E F-U2RFB-b 42EF-D1RFAK-b 42EF-S1RFA-b 42EF-B1RCFC-b 42EF-B1RFBE-b 42EF-G1RFA-b 42EF-R9RFB-b 42EF-R9RFBV-b
Voltage/Current/Power Consumption 21.6 to 264V AC/DC @ 2 5 mA maximum (1 VA maximum) 21.6 to 132 V AC/DC for 42EF-xxxFx-a models
Sensor Protection Input reverse polarity, over voltage, false pulseprotected, output short-circuit(SCP) to 100 mA, overload
AC/DC Sensors
Output Type Light/dark operate (N.O./N.C. ) MOSFET output
Output Rating 264V AC/DC (132V AC/ DC for 42EF-xxxFx-a models) @ 100 mA ma ximum (SCP protected)
Output Leakage Current 0.4mA maximum
Response Time 8.3mstypical,16msfortransmittedbeammodels
Provide NPN output when wired as DC circuit. a = (--A2) 2 m PVC, 300V cable, (--F4) 4--pin DC micro QD on six-inch pigtailProvide PNP output when wired as DC circuit. b = ( --A2) 2 m PVC, 300V cable, (--G4) 4- -pin AC micro QD on six-inch pigtailContact factory for availability of 8 m range receivers.
Transmitted beam source models: 42EF--E1EZB--a (DC) and 42EF--E1QZB--b (AC/DC)
flective
42EF-P2MNB-a 42EF-D1MNAK-a 42EF-S1MNA-a 42EF-B1MNBC-a 42EF-B1MNBE-a 42EF-G1MNA-a 42E F-R9MNB-a 42E F-R9MNBV-a
42EF-P2SCB-b 42EF -U2SCB-b 42EF-D1SCAK-b 42EF-S1SCA-b 42EF-B1SCBC-b 42EF-B1SCBE-b 42EF -G1SCA-b 42EF-R9SCB-b 42EF-R9SCBV-b
flective
Diffuse
Sharp Cutoff
Diffuse
-25to +55C(-13 to +131F) . 132V AC/DC
-25to +70C(-13 to +158F) . 132V AC/DC
R
Photoelectric Sensors
Background Suppression
50 mm (2 in.) 100 mm (4 in.) 20 m Receiver 4mReceiver
Glass Fiber Optic
Transmitted Beam
1
Page 2
Typical Response Curves
Polarized Retroreflective
6
5
4
3
2
OperatingMargin
1
(0.03)
Polarized Retroreflective Beam Pattern
20
10
0
-- 1 0
Beam Diameter [mm]
-- 2 0
Background Suppression
1000
100
10
Beam Diameter [mm]
1
0.1
0.01 (0.328)
Distance to 76 mmReflector, 92-39[m (ft)]
0
1
(3)
Distance [m (ft)]
20
040
(0.7)
Distance to White Target [mm (in.)]
1
(3.28)
2
(7)
50 mm
(1.5)60(2.3)80(3.1)
3
(10)
100 mm
(32.8)
100
(3.9)
Standard Retroreflective Diffuse Sharp Cutoff Diffuse
100
10
OperatingMargin
10
1
0.1
(0.328)
Distance[m (ft)]
Standard Retroreflective
150
100
50
0
-- 5 0
-- 1 0 0
Beam Diameter [mm]
--150
2
1
0
(7)3(10)4(13)5(16)6(20)
(3)
Distance[m (ft)]
(3.28)
1
(32.8)
10
100
10
OperatingMargin
1
(0.04)
0.1
1
(0.4)
Distanceto WhiteTarget [cm(in.)]
(3.9)
10
Diffuse Beam Pattern
15
5
0
-5
Beam Diameter [mm]
-15 20
040
(8)
(16)
Distance [cm (in.)]
100 (39)
60
(24)
Background Suppression Beam Pattern
4
2
0
-- 2
-- 4
Beam Diameter [mm]
02
50 mm
1
(3)
(7)3(10)4(13)5(16)6(20)
Distance [mm(in.)]
100 mm
Target
100
10
OperatingMargin
1
2.54 (0.1)
Distanceto WhiteTarget [mm(in.)]
25.4 (1.0)
Transmitted Beam—4 m Beam Pattern
0.2
0.1
0
-0.1
Beam Diameter [mm]
-0.2 1
0
(3)
Distance [m (ft)]
2
(7)3(10)4(13)
Glass Fiber Optic SensorsBackground Suppression Sensors
Sensitivity
Adjustment
254 (10)
Transmitted Beam
100
4m
(3.28)
20 m
10
1
(32.8)
10
OperatingMargin
1
0.1
(0.328)
Distance to White Target [m(ft)]
TransmittedBeam—20mBeamPattern
0.5
0.4
0.25
0.12 0
-0.12
-0.25
-0.4
Beam Diameter [mm]
-0.5
015
5
(17)
Distance [m (ft)]
10
(33)
Retaining
Clip
20
(67)
(50)
Groove in
end tip
100
(328)
Table 1: LED Function
Label Color State Status
OFF Output de‐energized
Output Yellow
Margin Orange
Status Green
Note: For DC models, output and margin LEDs alternate flashing when SCP is active.
ON Output energized
Flashing Output SCP active (DC models only)
OFF Margin <2.5
ON Margin >2.5
Flashing Output SCP active (AC models only)
OFF Sensor notpowered, output active, SCPactive
ON Sensor powered
Note: Due to the detection method, targets traveling horizontal to the sensor's optics are detected. Targets traveling vertically may not be accurately detected. For reliable background suppression, a minimum separation distance of 6 mm (0.24 in.) is recommended between the target and the backgrounds.
Sensor Alignment
The orange LED is an alignment aid which indicates that a margin of 2.5 has been reached. This means that the sensor is receiving at least 2.5 times the signal strength back from the target needed to trigger an output signal. In general, it is desirable to have a higher margin to help overcome any deteriorating environmental conditions, i.e., dust build-up on the sensor’s lens. When aligning the sensor, the best performance can be obtained if this margin indicator is illuminated with the target in place.
When aligning diffuse mode sensors, ensure that the sensitivity be set at its maximum setting using the single-turn adjustment knob on the front panel. Pan the sensor left, right, up, and down to center the beam on the target. It may then be necessary to decrease this setting to prevent the sensor from detecting a background object. If this problem persists, the application will require the use of a background suppression, sharp cutoff diffuse, or retroreflective sensing mode.
2
Page 3
Short‐Circuit Protection
RightSight photoelectric sensors provide short-circuit protection (SCP) on the output leads. This feature is intended to protect the sensor from damage in the event that the output load is shorted to ground. If this condition does occur, the SCP will activate and the orange LED wil flash until the source is removed (power must be reset for AC/DC models). The SCP limits are set to 100 mA over the entire voltage range for both DC and AC/DC models.
Wiring Diagrams
10.8-30V DC Sensors
Models with Dual NPN and PNP Outputs
Models with NPN Outputs
Models with PNP Outputs
Brown
White
Load
Black
Load
Blue
Cable Quick‐Disconnect
Brown
White
Load
Black
Load
Blue
Cable Quick‐Disconnect
Brown
Black
Load
White
Load
Blue
Cable Quick‐Disconnect
Brown
+
+
+
1
2
White
Load
Black
4
3
1
2
4
3
1
4
2
3
Blue
Brown
White Black
Blue
Brown
Black
White
Blue
Load
Load
Load
Load
Load
+
124
3
DC Micro
+
124
3
DC Micro
+
124
3
DC Micro
21.6--264V AC/DC Sensors
ACWiringfor42EF-___C__-__Models
Blue
Black
Load
Brown
Cable Quick‐Disconnect
ACWiringfor42EF-___F__-__Models
Brown
Black
Load
Blue
DCWiringfor42EF-___C__-__Models
DCWiringfor42EF-___F__-__Models
Brown
Black
Load
Blue
Cable Quick‐Disconnect
Brown
Black
Load
L1
L2
L1
L2
+
2
3
1
1
3
2
+
Red/White
Red
Load
Red/Black
1
3
2
1
3
Red/Black
Red
Red/White
Red/Black
Red
Red/White
Red/Black
Red
Load
Load
Load
L1
3
4
1
L2
L1
L2
+
3
4
1
+
2
2
Note: All wire colors on quick‐disconnect models shown refer to AllenBradley cordsets.
Blue
Transmitted Beam Source
AC and DC Wiring
Brown
Blue
Cable Quick‐Disconnect
3
L1/+
L2/-
2
1
2
Red/White
Red/Black
Red/White
L1/+
L2/-
Page 4
Sensor Dimensions [mm (in.)]
r
s
AC/DC
26.5
(1.04)
20.5
(0.81)
34.5
(1.36)
10
(0.40)
M18x1,0thread
16.5
(0.65)
9.6
(0.38)
32.7
(1.29)
19
(0.75)
2m(6.56ft)
(0.16)
4
cable
27
(1.06)
49.7
(1.96)
69
(2.72)
3.6 (0.145) dia.
clearance for #6-32
screw (2 places)
Sensitivity Adjustment (diffuse and glass fiber
optic only)
18 mm mounting nut
Indicators
DC
(0.40)
10
16.5
(0.65)
20.5
(0.81)
34.5
(1.36)
10
(0.40)
M18x1.0 thread
Accessories
Straight Bracket #60--2656 Right Angle Bracket #60--2657 Swivel/Tilt Bracket #60--2649 Apertures
10Adjustment in
each direction
57.15
(2.25)
28.6
(1.125)
Transmitted Beam and Retroreflective Sensing Modes only)
9.6
(0.38)
32.7
(1.29)
(0.75)
(0.16)
19
27
(1.06)
46.7
(1.84)
27.5
4
(1.08)
3.6 (0.145) dia.
clearance for #6-32
screw (2 places)
Accessories—Description Catalog Number
Mounting Kit 60-2716
Clamp StyleBracket 871A-BP18
Flush Mount Adaptor 60-2590
Field Mount Terminal Chamber—4‐pin DC micro 871A-TS4-DM Field Mount Terminal Chamber—3‐pin AC micro 871A-TS3-RM
Cordset—2 m (6.5 ft), 4pinDC micro 889D-F4AC-2 Cordset—2 m (6.5 ft), 4pinA Cmicro 889D-F4AEA-2
Reflector—1.25 inch diameter 92-47
Reflector—3 inch diameter 92-39
Fiber optic cable, glass, bifurcated, 5/ 16 in. threaded 43GR-TBB25SL
Fiber optic cable, glass, individu al, 5/16 in. threaded 43FT-TBB25SL
PHOTOSWITCH, Allen-Bradley, Rockwell Software, and Rockwell Automation are trademar ks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automationare property of their respective companies.
Rockwell Automation main tains current product environmental information on itswebsite at
http://www.rockwellautomati on.com/rockwellautomation/about-us/ sustainability-ethics/product-environmental-compliance.page
7.95
(0.31)
50.08
Notes
1. Damage may occur to sensor housing if torque above 20 in‐lb is applied to t he 18 mm lockout.
2. Fiber optic sens ors come with two 18 mm locknuts (7501 2-025-01). All other RightSight sen sors come with one thick 18 mm lock nut (75012-097-01).
3. Optional mounting ki t (60-2716) comes with two 75012-025-01, on e 75012-097-01 locknut, internal tooth s tar washer, and screws/n uts for throughhole
mounting.
(2.0)
Voltage and current ratings of the overcurrent protection to be used per UL 508:
Max. Current/Minimum Voltage Rating of Overcurrent Protection
5 A/300V 20 0.52
3 A/300V 22 0.33
2 A/300V 24 0.21
1 A/300V 26 0.13
0.8 A/300V 28 0.08
1mmQty.20#60-2660 2mmQty.20#60-2661 4mmQty.20#60-2662
Aperture Set (4 eac h) #60-2659
Conductor Size
AWG Sq. mm
Note:18mmnutmustbeinstalledprio
to installing aperture if threads on optic
snout are to be used.
Publication 42EF--IN003A--EN--P
PN-312958
4
April 2015
Printed in USA
Loading...