Catalog Numbers 2198-P031, 2198-P070, 2198-P141, 2198-P208, 2198-RP088, 2198-RP200, 2198-RP263, 2198-RP312, 2198-D006-ERS3, 2198-D012-ERS3, 2198-D020-ERS3, 2198-D032-ERS3, 2198-D057-ERS3, 2198-S086-ERS3, 2198-S130-ERS3, 2198-S160-ERS3, 2198-S263-ERS3, 2198-S312-ERS3, 2198-D006-ERS4, 2198-D012-ERS4, 2198-D020-ERS4, 2198-D032-ERS4, 2198-D057-ERS4, 2198-S086-ERS4, 2198-S130-ERS4, 2198-S160-ERS4, 2198-S263-ERS4, 2198-S312-ERS4, 2198T-W25K-ER, 2198-CAPMOD-2240, 2198-CAPMOD-DCBUS-IO, 2198-DCBUSCOND-RP312

Important User Information

Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited.
Throughout this manual, when necessary, we use notes to make you aware of safety considerations.
WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.
ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence.
IMPORTANT Identifies information that is critical for successful application and understanding of the product.
Labels may also be on or inside the equipment to provide specific precautions.
SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present.
BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures.
ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).

Table of Contents

Preface
Summary of Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Conventions Used in This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Access the Attachments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Additional Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Chapter 1
Start Kinetix 5700 Servo Drives Series Change. . . . . . . . . . . . . . . . . . . . . . . . 16
About the Kinetix 5700 Servo Drive System . . . . . . . . . . . . . . . . . . . . . 17
DC-bus Power Supply Input Power Configurations. . . . . . . . . . . . . . 19
Typical DC-bus Power Supply Configuration Example . . . . . . . 19
Multiple DC-Bus Power Supply Configuration Example. . . . . . 20
Extended DC-bus Configuration Example. . . . . . . . . . . . . . . . . . . 21
iTRAK Power Supply Configuration Example . . . . . . . . . . . . . . . 22
Regenerative Bus Supply Input Power Configurations. . . . . . . . . . . . 23
Typical Regenerative Bus Configuration Examples . . . . . . . . . . . 23
Extended Regenerative Bus Configuration Example . . . . . . . . . . 26
iTRAK Power Supply Configuration Example . . . . . . . . . . . . . . . 27
8720MC-RPS Power Supply Input Power Configuration. . . . . . . . . 28
Motor and Auxiliary Feedback Configurations . . . . . . . . . . . . . . . . . . 29
Typical Communication Configurations . . . . . . . . . . . . . . . . . . . . . . . . 30
Linear Topology. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Ring Topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Star Topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Functional Safety Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Hardwired Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Integrated Safety Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Safe Stop and Safe Monitor Configurations. . . . . . . . . . . . . . . . . . 36
Catalog Number Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Agency Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Plan the Kinetix 5700 Drive System Installation
Chapter 2
System Design Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
System Mounting Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
DC-bus Voltage Regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
AC Line Filter Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
AC Line Impedance Considerations . . . . . . . . . . . . . . . . . . . . . . . . 45
Circuit Breaker/Fuse Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
24V Control Power Evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Contactor Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Passive Shunt Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Active Shunt Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Enclosure Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Minimum Clearance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 56
Multi-axis Shared DC-Bus Configurations. . . . . . . . . . . . . . . . . . . 57
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 3
Table of Contents
Accessory Module Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
DC-bus Power Supply Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Regenerative Bus Supply Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8720MC-RPS or Other Regenerative Power Supply . . . . . . . . . . 64
Accessory Module Flowcharts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Electrical Noise Reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Bonding Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Bonding Multiple Subpanels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Establishing Noise Zones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Cable Categories for Kinetix 5700 Systems . . . . . . . . . . . . . . . . . . 72
Noise Reduction Guidelines for Drive System Accessories. . . . . 73
Chapter 3
Mount the Kinetix 5700 Drive System
Connector Data and Feature Descriptions
Determine Mounting Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Mount Accessory Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Zero-stack Tab and Cutout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Install Shared-bus Connection Systems . . . . . . . . . . . . . . . . . . . . . . . . . 84
DC-bus Connection System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
24V Input Power Connection System . . . . . . . . . . . . . . . . . . . . . . . 85
Drill-hole Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Drill-hole Pattern Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Drill-hole Patterns by Using the System Mounting Toolkit . . . 90
Mount Your Kinetix 5700 Drive Modules. . . . . . . . . . . . . . . . . . . . . . . 90
Chapter 4
Kinetix 5700 Connector Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Safe Torque-off Connector Pinout. . . . . . . . . . . . . . . . . . . . . . . . . 102
Input Power Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
DC Bus and Shunt Resistor Connector Pinouts . . . . . . . . . . . . . 103
Digital Inputs Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . 103
Ethernet Communication Connector Pinout . . . . . . . . . . . . . . . 105
Motor Power, Brake, and Feedback Connector Pinouts. . . . . . 105
Motor Feedback Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . 106
Universal Feedback Connector Pinouts . . . . . . . . . . . . . . . . . . . . 107
Accessory Module Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Understand Control Signal Specifications . . . . . . . . . . . . . . . . . . . . . . 108
Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Ethernet Communication Specifications . . . . . . . . . . . . . . . . . . . 109
Contactor Enable Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Converter OK Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Motor Brake Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Control Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Feedback Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Encoder Feedback Supported on the
DSL Feedback Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
4 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Table of Contents
Encoder Feedback Supported on the
UFB Feedback Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Auxiliary Feedback Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Encoder Phasing Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Absolute Position Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Functional Safety Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Hardwired STO Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Integrated Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Chapter 5
Connect the Kinetix 5700 Drive System
Basic Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Routing the Power and Signal Cables. . . . . . . . . . . . . . . . . . . . . . . 128
Input Power Configurations for Kinetix 5700 Power Supplies . . . 129
DC-bus Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Regenerative Bus Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Ground Screw/Jumper Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Kinetix 5700 Drive System Power Supply. . . . . . . . . . . . . . . . . . . 135
Kinetix 5700 Inverters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Kinetix 5700 iTRAK Power Supply . . . . . . . . . . . . . . . . . . . . . . . . 137
Remove/Install the Ground Screw/Jumper . . . . . . . . . . . . . . . . . . . . . 137
Ground the Drive System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Ground the System Subpanel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Ground Multiple Subpanels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Wiring Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Wiring Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Wire the Power Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Wire the 24V Control Power Input Connector . . . . . . . . . . . . . 145
Wire the Input Power Connector. . . . . . . . . . . . . . . . . . . . . . . . . . 147
Wire the Contactor Enable Connector . . . . . . . . . . . . . . . . . . . . . 148
Wire the Digital Input Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
2198-xxxx-ERS3 (series A) Connector Plugs. . . . . . . . . . . . . . . . 149
2198-xxxx-ERS4 and 2198-xxxx-ERS3 (series B)
Connector Plugs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Wire the Safe Torque-off Connector. . . . . . . . . . . . . . . . . . . . . . . 150
Wire the Digital Inputs Connector . . . . . . . . . . . . . . . . . . . . . . . . 151
Wire Motor Power and Brake Connectors . . . . . . . . . . . . . . . . . . . . . 152
Maximum Cable Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Wiring Single Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
Motor Feedback Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Apply the Single Motor Cable Shield Clamp. . . . . . . . . . . . . . . . 161
Wiring Power/Brake and Feedback Cables . . . . . . . . . . . . . . . . . . . . . 163
Motor Power and Brake Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Motor Power/Brake Cable Series Change. . . . . . . . . . . . . . . . . . . 164
Dual-axis Inverter Power/Brake Cable Installation . . . . . . . . . . 165
Single-axis Inverter Power/Brake Cable Installation . . . . . . . . . 168
Motor Feedback Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
Customer-supplied Motor Power Cables . . . . . . . . . . . . . . . . . . . . . . . 178
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 5
Table of Contents
Configure and Start the Kinetix 5700 Drive System
Accessory Module Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
External Passive-shunt Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
External Active-shunt Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
DC-bus Power Supply Active Shunt Connections. . . . . . . . . . . 183
Regenerative Bus Supply Active Shunt Connections . . . . . . . . . 183
Wire the External DC-bus Connections. . . . . . . . . . . . . . . . . . . . 184
Bulletin VPC Motors and the Extended Speed Feature . . . . . . 185
Considerations for Powerohm Shunt Installation . . . . . . . . . . . 185
Ethernet Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Chapter 6
Understand the Kinetix 5700 Display. . . . . . . . . . . . . . . . . . . . . . . . . . 188
Menu Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Setup Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
Startup Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Configure the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
Set the Network Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
Studio 5000 Logix Designer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
Version History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
Install the Kinetix 5700 Add-On Profile. . . . . . . . . . . . . . . . . . . . 199
Configure the Logix 5000 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Configure the Kinetix 5700 Drive Modules . . . . . . . . . . . . . . . . . . . . 203
Configure the DC-bus Power Supply. . . . . . . . . . . . . . . . . . . . . . . 203
Configure the Regenerative Bus Supply. . . . . . . . . . . . . . . . . . . . . 207
Configure the Inverter Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Continue Inverter Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 219
Configure the Motion Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Configure Regenerative Bus Supply Axis Properties . . . . . . . . . . . . . 224
Configure Vertical Load Control Axis Properties . . . . . . . . . . . . . . . 229
Configure Feedback-only Axis Properties . . . . . . . . . . . . . . . . . . . . . . 230
Configure Induction-motor Frequency-control Axis Properties . . 232
General and Motor Categories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
Basic Volts/Hertz Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
Sensorless Vector Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
Fan/Pump Volts/Hertz Method. . . . . . . . . . . . . . . . . . . . . . . . . . . 239
Configure IPM Motor Closed-loop Control Axis Properties . . . . . 241
Configure SPM Motor Closed-loop Control Axis Properties. . . . . 245
Configure Induction-motor Closed-loop Control Axis Properties 249
Configure Feedback Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
Configure Module Properties. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
Configure Axis Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
Download the Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
Apply Power to the Kinetix 5700 Drive System . . . . . . . . . . . . . . . . . 262
Understand Bus-sharing Group Configuration . . . . . . . . . . . . . . . . . 263
Bus-sharing Group Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
Configure Bus-sharing Groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
Test and Tune the Axes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
6 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Table of Contents
Test the Axes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
Tune the Axes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269
Chapter 7
Troubleshoot the Kinetix 5700 Drive System
Remove and Replace Drive Modules
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
Interpret Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
Display Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
Fault Code Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
Fault Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
SAFE FLT Fault Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
Kinetix 5700 Status Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
Kinetix 5700 Accessory Module Status Indicators . . . . . . . . . . . 279
Axis Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
Regenerative Bus Supply Troubleshooting. . . . . . . . . . . . . . . . . . . . . . 281
Logix 5000 Controller and Drive Module Behavior . . . . . . . . . . . . . 283
DC-bus Power Supply Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Regenerative Bus Supply Behavior . . . . . . . . . . . . . . . . . . . . . . . . . 286
iTRAK Power Supply Behavior. . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
Inverter Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
Chapter 8
Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
Remove and Replace Kinetix 5700 Drive Modules . . . . . . . . . . . . . . 296
Remove Power and All Connections . . . . . . . . . . . . . . . . . . . . . . . 296
Remove the Drive Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Replace the Drive Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
Start and Configure the Drive Module . . . . . . . . . . . . . . . . . . . . . . . . . 302
Replacing 2198-xxxx-ERS3 (series A) Drives with
Series B Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
Kinetix 5700 Safe Torque-off Function
Chapter 9
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
Average Frequency of a Dangerous Failure . . . . . . . . . . . . . . . . . . 307
Safe Torque-off Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
Out of Box State. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308
Safe Torque-off Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
Explicit Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
Hardwired Safe Torque-off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
Compatible Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
Description of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
Troubleshoot the Safe Torque-off Function . . . . . . . . . . . . . . . . 316
Safe Torque-off Connector Data. . . . . . . . . . . . . . . . . . . . . . . . . . . 317
Wire the Safe Torque-off Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . 318
Safe Torque-off Wiring Requirements. . . . . . . . . . . . . . . . . . . . . . 320
Safe Torque-off Feature Bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 7
Table of Contents
Cascade the Safe Torque-off Signal. . . . . . . . . . . . . . . . . . . . . . . . . 321
Hardwired Safe Torque-off Electrical Specifications . . . . . . . . . 323
Integrated Safe Torque-off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
Compatible Safety Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324
Safety Application Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 324
Description of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
Safe Torque-off Assembly Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
STO Fault Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
Troubleshoot the Safe Torque-off Function . . . . . . . . . . . . . . . . 329
Understand Integrated Safety Drive Replacement . . . . . . . . . . . 330
Replace an Integrated Safety Drive in a GuardLogix System . . 331
Motion Direct Commands in Motion Control Systems. . . . . . 332
Integrated Safe Torque-off Specifications. . . . . . . . . . . . . . . . . . . 339
Appendix A
Interconnect Diagrams Interconnect Diagram Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
Power Wiring Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
Capacitor Module Status Wiring Example. . . . . . . . . . . . . . . . . . . . . . 357
DC-bus Conditioner Module Status Wiring Example . . . . . . . . . . . 357
Contactor Wiring Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358
Passive Shunt Wiring Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
Active Shunt Wiring Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360
Kinetix 5700 Servo Drive and Rotary Motor Wiring Examples. . . 362 Kinetix 5700 Servo Drive and Linear Actuator Wiring Examples . 367
System Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
Appendix B
Upgrade the Drive Firmware Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382
Configure Logix 5000 Controller Communication. . . . . . . . . . 383
Inhibit Feedback Only Axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
Upgrade Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385
Verify the Firmware Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
Appendix C
Size Multi-axis Shared-bus Configurations
Shared DC-bus Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391
Shared DC-bus Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391
General Sizing Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393
System Sizing Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393
Select Drive/Motor Combinations. . . . . . . . . . . . . . . . . . . . . . . . . 394
Select the Power Supply and Define the DC-bus Groups. . . . . 394
Calculate System and External-bus Capacitance . . . . . . . . . . . . . 394
Calculate the Total Motor Power Cable Length. . . . . . . . . . . . . 395
Calculate 24V DC Control Power Current Demand . . . . . . . . 396
24V DC Voltage Drop Calculation Example. . . . . . . . . . . . . . . . 397
System Sizing Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
System Sizing Application Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
8 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Appendix D
Table of Contents
Maximum Motor Cable Lengths for Kinetix 5700 Power Supplies
DC-bus Power Supply Configurations . . . . . . . . . . . . . . . . . . . . . . . . . 402
Regenerative Bus Supply Configurations . . . . . . . . . . . . . . . . . . . . . . . 404
Appendix E
Motor Control Feature Support Frequency Control Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
Basic Volts/Hertz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407
Basic Volts/Hertz for Fan/Pump Applications . . . . . . . . . . . . . . 408
Sensorless Vector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409
Current Limiting for Frequency Control. . . . . . . . . . . . . . . . . . . . . . . 410
The Effects of Current Limiting . . . . . . . . . . . . . . . . . . . . . . . . . . . 410
Enable the Current Limiting Feature. . . . . . . . . . . . . . . . . . . . . . . 412
Set the CurrentVectorLimit Attribute Value. . . . . . . . . . . . . . . . 412
Stability Control for Frequency Control . . . . . . . . . . . . . . . . . . . . . . . 413
Enable the Stability Control Feature . . . . . . . . . . . . . . . . . . . . . . . 414
Skip Speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
Multiple Skip Speeds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416
Flux Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417
Flux Up Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
Configure the Flux Up Attributes. . . . . . . . . . . . . . . . . . . . . . . . . . 419
Current Regulator Loop Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420
Motor Category. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420
Motor Tests and Autotune Procedure . . . . . . . . . . . . . . . . . . . . . . 422
Motor Analyzer Category Troubleshooting. . . . . . . . . . . . . . . . . 423
Selection of Motor Thermal Models . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
Generic Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
Thermally Characterized Motors . . . . . . . . . . . . . . . . . . . . . . . . . . 427
Speed Limited Adjustable Torque (SLAT) . . . . . . . . . . . . . . . . . . . . . 428
Motion Polarity Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 428
SLAT Min Speed/Torque. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 429
SLAT Max Speed/Torque. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430
SLAT Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430
Configure the Axis for SLAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 431
Motion Drive Start (MDS) Instruction. . . . . . . . . . . . . . . . . . . . . 434
Motor Overload Retention. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
Phase Loss Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 440
Phase-loss Detection Attributes. . . . . . . . . . . . . . . . . . . . . . . . . . . . 441
Phase-loss Detection Configuration. . . . . . . . . . . . . . . . . . . . . . . . 441
Phase Loss Detection Current Example . . . . . . . . . . . . . . . . . . . . 442
Velocity Droop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 443
Closed Loop Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 443
Frequency Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 443
Velocity Droop Attribute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 443
Velocity Droop Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444
Commutation Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 445
Adaptive Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 445
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 9
Table of Contents
Field Weakening Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446
Extended Speed Feature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446
Configure Extended Speed Operation . . . . . . . . . . . . . . . . . . . . . . 447
Index
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 449
10 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019

Preface

This manual provides detailed installation instructions for mounting and wiring your Kinetix® 5700 power supplies, single-axis inverters, dual-axis inverters, and accessory modules. Also included is system configuration with the Studio 5000 Logix Designer® application, integration of your drive modules with a Logix 5000™ controller, system startup, and troubleshooting.
Also provided in this manual are installation instructions for mounting and wiring input power for your iTRAK® power supply. For wiring iTRAK digital inputs, outputs to the motor modules, and startup, troubleshooting, and commissioning with the AOI, see the iTRAK System User Manual, publication 2198T-UM001
This manual is intended for engineers or technicians directly involved in the installation and wiring of the Kinetix 5700 drive modules, and programmers directly involved in the operation, field maintenance, and integration of these modules with the EtherNet/IP™ communication module or controller.
If you do not have a basic understanding of Kinetix 5700 drive modules, contact your local Rockwell Automation sales representative for information on available training courses.
.

Summary of Changes

This manual contains new and updated information as indicated in the following table.
Table 1 - Summary of Changes
Top ic Page
Added the following drive module catalog numbers, specifications, features, pinouts, mounting, wiring, configuration in the Logix Designer application, and troubleshooting information:
• 2198-RPxxx regenerative bus supplies
• 2198-S263-ERSx and 2198-S312-ERSx single-axis inverters
• 2198-DCBUSCOND-RP312 DC-bus conditioner module
Added Kinetix VP (Bulletin VPAR) electric cylinders as another compatible linear actuator with Kinetix 5700 servo drives.
Updated the maximum current rating (40 A) for the 24V input power shared-bus connection system.
Moved fault code tables (FLT Sxx, FLT Mxx, and INIT FLT for example), previously in Troubleshoot the Kinetix 5700 Drive System (chapter 7), to the attached spreadsheet.
Added 2198-DBRxx-F AC line filters. 18
Added the 2198-BARCON-220DC200 DC-bus link to support the 2198-S263-ERSx and 2198-S312-ERSx single-axis inverters. 24
Added the following DC-bus links to support the 2198-RPxxx regenerative bus supplies:
• 2198-BARCON-165DC200
• 2198-BARCON-275DC200
• 2198-BARCON-440DC200
Added the 842E-CM integrated motion encoder to the star communication topology diagram. 32
Added DC-bus Voltage Regulation that explains how the regenerative bus supply can be configured to operate as a DC-bus power supply. 42
Added AC Line Filter Selection that matches line filter catalog numbers to Kinetix 5700 power supplies. 44
Added AC Line Impedance Considerations that provides guidelines for transformer and line reactor selection. 45
Added 24V Control Power Evaluation that provides guidelines to minimize 24V control power voltage drop. 49
Added Passive Shunt Considerations and Active Shunt Considerations that provide guidelines for shunt module selection. 51, 52
Added Multi-axis Shared DC-bus Configurations that provides guidelines for system sizing. 57
Throughout
13
24
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 11
Preface
Table 1 - Summary of Changes (continued)
Top ic Page
• Added Accessory Module Selection with DC-bus power supply configurations that moved from chapter 3.
• Added regenerative bus supply system configurations illustrating the minimum number of accessory modules required.
Updated the 8720MC-RPS or Other Regenerative Power Supply example configurations with a DC-bus conditioner module. 64
Added accessory module flowcharts designed to help determine the minimum number of accessory modules required. 65
Added the 2198-S312-P-T control power T-connector and bus bar to support 2198-S263-ERSx and 2198-S312-ERSx single-axis inverters. 87
Added Converter OK Relay that explains how the circuitry is used to support applications that migrate from 8720MC-RPS units to the 2198-RPxxx regenerative bus supply.
Added footnotes (1) and (2) that further specify wire size to meet CE requirements for 2198-P070 DC-bus power supplies. 141
Updated Maximum Cable Lengths with examples for 2198-RPxxx regenerative bus supplies. 155
Added Customer-supplied Motor Power Cables to support wiring 2198-S263-ERSx and 2198-S312-ERSx single-axis inverter applications that require conductors larger than 2 AWG.
Updated External Active-shu nt Connections with Powerohm catalog numbers that apply to regenerative bus supplies and added information for wiring regenerative bus supplies to the Active Shunt (RC) connector.
Added Hardware Fault Tolerance (HFT) specifications to the table. 307
Added Active Shunt Wiring Examples. 360
Added external-bus capacitance calculations and updated the System Sizing Example with the external-bus capacitance value. 399
Added the Maximum Motor Cable Lengths for Kinetix 5700 Power Supplies (Appendix D). 401
Updated Motor Analyzer Category Troubleshooting with rated slip-speed information. 423
59
111
172
183

Conventions Used in This Manual

These conventions are used throughout this manual:
• Bulleted lists such as this one provide information, not procedural steps
• Numbered lists provide sequential steps or hierarchical information
• When catalog number 2198-xxxx-ERS3 appears in this publication without series designation, the topic applies to series A and B drives
IMPORTANT Throughout this publication, when the Kinetix 5700 inverter catalog
number ends in -ERSx, for example 2198-D057-ERSx, the variable (x) indicates that the inverter (using this example) can be 2198-D057-ERS3 or 2198-D057-ERS4.
• The 2198-CAPMOD-2240 capacitor module, 2198-CAPMOD­DCBUS-IO extension module, and 2198-DCBUSCOND-RP312 DC-bus conditioner module are collectively referred to as accessory modules
12 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Preface

Access the Attachments

Additional Resources

Table 2 - Additional Resources
The Microsoft Excel spreadsheet that is attached to this publication contains fault code descriptions. To use the spreadsheet file, click the Attachments link
, right-click the spreadsheet file, and save the file to your computer.
If the PDF file opens in a browser and you don't see the Attachments link , download the PDF file and reopen the file with the Adobe Acrobat Reader
application.
These documents contain additional information concerning related products from Rockwell Automation.
Resource Description
Kinetix Rotary Motion Specifications Technical Data, publication KNX-TD001
Kinetix Linear Motion Specifications Technical Data, publication KNX-TD002
Kinetix Servo Drives Specifications Technical Data, publication KNX-TD003
Kinetix Motion Accessories Specifications Technical Data, publication KNX-TD004
AC Line Filter Installation Instructions, publication 2198-IN003
Kinetix 5700 Regenerative Bus Supply Installation Instructions, publication 2198-IN014
Kinetix 5700 Capacitor Modules Installation Instructions, publication 2198-IN008 Provides information on installing and wiring the Kinetix 5700 capacitor modules.
Replacement Fan Kit Installation Instructions, publication 2198-IN015
Kinetix 5700 DC-bus Conditioner Module Installation Instructions, publication 2198-IN016
Kinetix 5700 Shunt Passive Modules Installation Instructions, publication 2198-IN011 Provides information on installing and wiring Kinetix 5700 passive shunts.
Kinetix 5700 Safe Monitor Functions Safety Reference Manual, publication 2198-RM001
iTRAK System User Manual, publication 2198T-UM001
Provides product specifications for Kinetix VP (Bulletin VPL, VPC, VPF, and VPS), MP-Series™ (Bulletin MPL, MPM, MPF, and MPS), and HPK-Series™ rotary motors.
Provides product specifications for Bulletin MPAS and MPMA linear stages, Bulletin VPAR, MPAR, and MPAI electric cylinders, LDAT-Series linear thrusters, and LDC-Series™ linear motors.
Provides product specifications for Kinetix Integrated Motion over the EtherNet/IP network, Integrated Motion over sercos interface, EtherNet/IP networking, and component servo drive families.
Provides product specifications for Bulletin 2090 motor and interface cables, low­profile connector kits, drive power components, and other servo drive accessory items.
Provides information on installing and wiring the Kinetix 5500 and Kinetix 5700 AC line filters.
Provides information on installing and wiring the Kinetix 5700 regenerative bus supply.
Provides information on removal and replacement of cooling fans used in 2198­RPxxx regenerative bus supplies and 2198-S263-ERSx and 2198-S312-ERSx single- axis inverters.
Provides information on installing and wiring the Kinetix 5700 DC-bus conditioner module.
Provides a description of integrated stopping functions and safe monitoring functions with a GuardLogix® controller and Kinetix 5700 servo drives.
Provides information on installing the Kinetix 5700 iTRAK power supply with an iTRAK system and programming the iTRAK system.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 13
Preface
Table 2 - Additional Resources (continued)
Resource Description
1321 Power Conditioning Products Technical Data, publication 1321-TD001
8720MC Regenerative Power Supply Installation Manual, publication 8720MC-RM001
System Design for Control of Electrical Noise Reference Manual, publication GMC-RM001
Kinetix Motion Control Selection Guide, publication KNX-SG001
Kinetix 5700 Drive Systems Design Guide, publication KNX-RM010
Rockwell Automation Product Selection website http://www.rockwellautomation.com/global/support/selection.page
Motion Analyzer System Sizing and Selection Tool website https://motionanalyzer.rockwellautomation.com/
Product Certifications website, rok.auto/certifications
Motor Nameplate Datasheet Entry for Custom Motor Applications Application Technique, publication 2198-AT002
Vertical Load and Holding Brake Management Application Technique, publication MOTION-AT003
Motion System Tuning Application Technique, publication MOTION-AT005 Provides information on tuning a Kinetix drive system.
Integrated Motion on the EtherNet/IP Network Configuration and Startup User Manual, publication MOTION-UM003
Integrated Motion on the EtherNet/IP Network Reference Manual, publication MOTION-RM003
GuardLogix 5570 Controllers User Manual, publication 1756-UM022
GuardLogix 5580 Controllers User Manual, publication 1756-UM543
Compact GuardLogix 5370 Controllers User Manual, publication 1769-UM022
Compact GuardLogix 5380 Controllers User Manual, publication 5069-UM001
GuardLogix 5570 and Compact GuardLogix 5370 Controller Systems Safety Reference Manual, publication 1756-RM099
GuardLogix 5580 and Compact GuardLogix 5380 Controller Systems Safety Reference Manual, publication 1756-RM012
ControlFL ASH Firmware Upgrade Software User Manual, publication 1756-UM105 For ControlFLASH™ information not specific to any drive family.
Rockwell Automatio n Industrial Automation Glossary, publication AG-7 .1
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1
Provides information on typical use cases, specifications, terminations, and dimensions of Bulletin 1321 line reactors.
Provides information on installing, wiring, and startup for the 8720MC regenerative power supply with 380…460V AC operation.
Provides information, examples, and techniques designed to minimize system failures caused by electrical noise.
Overview of Kinetix ser vo drives, motors, actuators, and motion accessories designed to help make initial decisions for the motion control products best suited for your system requirements.
System design guide to select the required (drive specific) drive module, power accessory, feedback connector kit, and motor cable catalog numbers for your Kinetix 5700 drive system.
Online product selection and system configuration tools, including AutoCAD (DXF) drawings.
Comprehensive motion application sizing tool used for analysis, optimization, selection, and validation of your Kinetix Motion Control system.
Provides declarations of conformity, certificates, and other certification details.
Provides information on the use of nameplate data entry for custom induction motors and permanent-magnet motors that are used in applications with Kinetix 5700 servo drives.
Provides information on vertical loads and how the servo motor holding-brake option can be used to help keep a load from falling.
Provides information on configuring and troubleshooting your ControlLogix® and CompactLogix™ EtherNet/IP network modules.
Provides information on the AXIS_CIP_DRIVE attributes and the Studio 5000 Logix Designer application Control Modes and Methods.
Provides information on how to install, configure, program, and use ControlLogix controllers and GuardLogix controllers in Studio 5000 Logix Designer projects.
Provides information on how to install, configure, program, and use CompactLogix and Compact GuardLogix controllers.
Provides information on how to achieve and maintain Safety Integrity Level (SIL) and Performance Level (PL) safety application requirements for GuardLogix and Compact GuardLogix controllers.
A glossary of industrial automation terms and abbreviations.
Provides general guidelines for installing a Rockwell Automation industrial system.
You can view or download publications at
http://www.rockwellautomation.com/global/literature-library/overview.page
14 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
.
Chapter 1
Start
Use this chapter to become familiar with the Kinetix® 5700 drive system and obtain an overview of installation configurations.
Top ic Pa ge
Kinetix 5700 Servo Drives Series Change 16
About the Kinetix 5700 Servo Drive System 17
DC-bus Power Supply Input Power Configurations 19
Regenerative Bus Supply Input Power Configurations 23
8720MC-RPS Power Supply Input Power Configuration 28
Motor and Auxiliary Feedback Configurations 29
Typical Communication Configurations 30
Functional Safety Configurations 33
Catalog Number Explanation 37
Agenc y Compliance 39
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 15
Chapter 1 Start

Kinetix 5700 Servo Drives Series Change

Single-axis and dual-axis inverters, catalog numbers 2198-xxxx-ERS3 (series B), include an enhancement that is not included in series A drives, but that is included in 2198-xxxx-ERS4 drives.
• The drive-based (Monitored SS1 and Timed SS1) stopping functions and controller-based monitoring functions apply to the 2198-xxxx-ERS4 drives
• The drive-based Timed SS1 stopping function and STO with configurable delay applies to the 2198-xxxx-ERS3 (series B) drives
• When catalog number 2198-xxxx-ERS3 appears in this publication without series designation, the topic applies to series A and B drives
Table 3 - Integrated Functional Safety Support
Integrated Safety Over the EtherNet/IP™ Network
Drive-based stopping functions
Controller-based stopping functions
Controller-based monitoring functions
Safety feedback function Safety Feedback Interface (SFX)
Integrated STO mode Safe Torque-off (STO)
(1) Where a ControlLogix or CompactLogix (non-safety) controller is specified, a GuardLogix or Compact GuardLogix controller is backwards compatible. Also, GuardLogix 5580 and Compact GuardLogix
5380 controllers are backwards compatible with GuardLogix 5570 and Compact GuardLogix 5370 controllers.
Safety Func tion
Timed Safe Stop 1 (SS1)
Monitored Safe Stop 1 (SS1)
• Monitored Safe Stop 1 (SS1)
• Safe Stop 2 (SS2)
• Safe Operational Stop (SOS)
• Safely Limited Speed (SLS)
• Safety Limited Position (SLP)
• Safe Direction (SDI)
Dual-axis Inverters Cat. No.
2198-Dxxx-ERS3 (series B) 2198-Dxxx-ERS4
2198-Dxxx-ERS4 2198-Sxxx-ERS4
2198-Dxxx-ERS4 2198-Sxxx-ERS4
2198-Dxxx-ERS3 2198-Sxxx-ERS3
Single-axis Inverters Cat. No.
2198-Sxxx-ERS3 (series B) 2198-Sxxx-ERS4
Minimum Controller Required
• GuardLogix® 5580
• CompactLogix™ 5380
• ControlLogix® 5570
• CompactLogix 5370
(1)
16 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Start Chapter 1

About the Kinetix 5700 Servo Drive System

Table 4 - Kinetix 5700 Drive System Overview
Drive System Component
Kinetix 5700 DC-bus Power Sup ply
Kinetix 5700 Regenerative Bus Supply
Kinetix 5700 Single­axis Servo Drives
Kinetix 5700 Dual­axis Servo Drives
Kinetix 5700 iTRAK Power Sup ply
Kinetix 5700 Capacitor Module
Kinetix 5700 Extension Module
Kinetix 5700 DC-bus Conditioner Module
8720MC Regenerative Power Sup ply
Shared-bus Connector Kits
DSL Feedback Connector Kit
Universal Feedback Connector Kit
Hiperface to DSL Converter Kit
Cat. No. Description
2198-Pxxx
2198-RPxxx
2198-Sxxx-ERS3
2198-Sxxx-ERS4
2198-Dxxx-ERS3
2198-Dxxx-ERS4
2198T-W25K-ER DC-DC converter that generates DC-bus power for iTRAK® systems.
2198-CAPMOD-2240
2198-CAPMOD-DCBUS-IO
2198-DCBUSCOND-RP312
8720MC-RPSxxx
2198-TCON-24VDCIN36 2198-xxxx-P-T 2198-BARCON-xxDCAC100
2198T-W25K-P-IN 2198T-W25K-P-T
2198-BARCON-xxDC200 2198-KITCON-ENDCAP200
2198-KITCON-DSL
2198-K57CK-D15M
2198-H2DCK (series B or later)
The Kinetix 5700 drive modules are zero-stacked and use the shared-bus connection system to extend power from one drive module to another. Systems are designed to support Integrated Motion over the EtherNet/IP network.
Converter power supply with 400V-class (three-phase) AC input. Provides power in a range of 7…46 kW and
10.5…69.2 A output current. Systems typically consist of one module, however, up to three modules in parallel is possible. Parallel modules increase available power for Bulletin 2198 single-axis and dual-axis inverters.
Regenerative bus supply with 400V-class (three-phase) AC input provides continuous output power and current to Bulletin 2198 single-axis and dual-axis inverters for applications with requirements in the range of 24…140 kW and 35…207 A, output current.
Single-axis inverters with current ratings up to 192 A rms. Drives feature TÜV Rheinland certified safe torque-off function with hardwired and integrated safety connection options, PL e and SIL 3 safety ratings, and support for DSL, Hiperface, and Heidenhain EnDat encoder feedback. 2198-Sxxx-ERS3 (series B) drives also support Timed SS1 drive­based stopping functions.
Single-axis inverters with the same power structure and encoder feedback support as -ERS3 inverters, plus support for Monitored SS1 and Timed SS1 drive-based stopping functions. Also, support for controller-based safe stop and safe monitor functions over the EtherNet/IP network.
Dual-axis inverters with current ratings up to 23 A rms. Drives feature TÜV Rheinland certified safe torque-off function with hardwired and integrated safety connection option s, PL e and SIL 3 safety ratings, and support for DSL, Hiperface, and Heidenhain EnDat encoder feedback. 2198-Dxxx-ERS3 (series B) drives also support Timed SS1 drive-based stopping functions.
Dual-axis inverters with the same power struc ture and encoder feedback support as -ERS3 inverters, plus support for Monitored SS1 and Timed SS1 drive-based stopping functions. Also, support for controller-based safe stop and safe monitor functions over the EtherNet/IP network.
Use for energy storage, external active-shunt connection, and to extend the DC-bus voltage to another inver ter cluster. Modules are zero-stacked with servo drives and use the shared-bus connection system to extend the ex ternal DC-bus voltage in applications up to 104 A. Can parallel with itself or with another accessory module for up to 208 A with required 2198-KITCON-CAPMOD2240 kit that includes flexible bus-bars.
The extension module, paired with a capacitor module or DC-bus conditioner module, is used to extend the DC-bus voltage to another inverter cluster in systems with ≥104 A current and up to 208 A.
Decreases the voltage stress on insulation components in an inverter system and used to extend the DC-bus voltage to another inverter cluster. Modules are zero-stacked with servo drives and use the shared-bus connection system to extend the external DC-bus voltage in applications up to 104 A. Can parallel with itself or with another accessory module for up to 208 A with required 2198-KITCON-DCBUSCOND kit that includes flexible bus-bars.
Sinusoidal PWM converter that can control the increase of DC-bus voltage and perform continuous power generation for one or more servo drives in multi-axis DC common-bus configurations.
24V input wiring connectors, T-connectors, and bus-bars for most Kinetix 5700 drive modules that use the 24V shared­bus connection system (optional).
24V input wiring connector, T-connector, and bus-bar for the iTRAK motor module and other select Kinetix 5700 drive modules that use the 24V shared-bus connection system (optional).
DC-bus links (55, 85, 100, and 220 mm) and end caps for the DC-bus shared-bus connection system (required and included with each respective drive module). DC-bus links (165, 275, and 440 mm) are optional and do not ship with any modules.
Replacement DSL motor feedback connector kit with 2-pin connector plug and grounding plate inside the connector housing. Supports 400V-class Kinetix VP rotary motors. Included with 2090-CSxM1DE motor cables. Must be purchased separately when used with 2090-CSxM1DG motor cables.
Universal feedback connector kit for motor and auxiliary feedback connections with the 15-pin connector plug and grounding plate inside the connector housing. Supports 400V-class MP-Series™ and HPK-Series™ rotary motors, MP­Series linear actuators, LDAT-Series linear thrusters, and LDC-Series™ linear motors.
Provides Hiperface-to-DSL feedback conversion for use with compatible 400V-class motors and actuators.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 17
Chapter 1 Start
Table 4 - Kinetix 5700 Drive System Overview (continued)
Drive System Component
Kinetix 5700 System Mounting Toolkit
Kinetix 5700 Cable Clamp Spacer Kit
Encoder Output Module
Logix 5000™ Controller Platform
Studio 5000® Environment
Rotary Servo Motors
Linear Actuators
Linear Motors LDC-Series Compatible motors include LDC-Series iron-core (400V-class) linear motors.
Induction Motors N/A Induction motors with open-loop frequency control and closed-loop control are supported.
Cables
AC Line Filters
Line Reactors 1321-3Rxx-x
AC Contac tor
24V DC Power Supply 1606-XLxxx Bulletin 1606 24V DC power supply for control circuitry, digital inputs, safety, and motor brake.
External Passive Shunt Resistors
External Active Shunts
Cat. No. Description
2198-K5700-MOUNTKIT Use to position the drive modules and identify drill-holes for mounting your Kinetix 5700 servo drive system.
2198-K5700-CLAMPSPACER Replacement cable clamp spacers for 2198-Dxxx-ERSx dual-axis inverters.
2198-ABQE
Bulletin 1769 Bulletin 5069
1756-EN2T module 1756-EN2TR module 1756-EN3TR module
N/A
Kinetix VP Compatible motors include 400V-class Bulletin VPL, VPC, VPF, and VPS ser vo motors.
MP-Series Compatible motors include 400V-class Bulletin MPL, MPM, MPF, and MPS servo motors.
HPK-Series Compatible motors include 460V and 400V-class HPK-Series asynchronous servo motors.
Kinetix VP, MP-Series, LDAT-Series
2090-CSxM1DE-xxAxxx
2090-CSxM1DG-xxAxxx
2090-CFBM7DF-CEAxxx Bulletin 2090 motor feedback cables for MP-Series motors and actuators with Stegmann Hiperface encoders.
2090-CPxM7DF-xxAxxx Bulletin 2090 motor power/brake cables for MP-Series motors and actuators.
2090-XXNFMF-Sxx 2090-CFBM7DF-CDAFxx
2198T-CHBFLS8-12AAxx Bulletin 2198T power cables for iTRAK power supply to iTRAK motor modules.
1585J-M8CBJM-x Ethernet cables are available in standard lengths. Shielded cable is required to meet EMC specifications.
2198-DB20-F, 2198-DB42-F, 2198-DB80-F, 2198-DB290-F
2198-DBR20-F, 2198-DBR40-F, 2198-DBR90-F, 2198-DBR200-F
100-Cxxxxx 100-Dxxxxx 100-Exxxxx
2198-R014, 2198-R031, 2198-R127, 2198-R004
N/A
The Allen-Bradley® encoder output module is a DIN-rail mounted EtherNet/IP network-based standalone module capable of outputting encoder pulses to a customer-supplied peripheral device (cameras, for example, used in line­scan vision systems).
Integrated Motion on the EtherNet/IP network in CompactLogix 5370 and CompactLogix 5380 controllers and Integrated Safety in Compact GuardLogix 5370 and Compact GuardLogix 5380 controllers. Linear, device-level ring (DLR), and star topology is supported.
EtherNet/IP network communication modules for use with ControlLogix 5570, ControlLogix 5580, GuardLogix 5570, and GuardLogix 5580 controllers. Linear, device-level ring (DLR), and star topology is supported.
Studio 5000 Logix Designer® application, version 26.00 or later, provides support for programming, commissioning, and maintaining the CompactLogix, ControlLogix, and GuardLogix controller families.
Compatible actuators include 400V-class Bulletin MPAS linear stages, Bulletin VPAR, MPAR, and MPAI electric cylinders, and LDAT-Series linear thrusters.
Bulletin 2090 single cable for motor power, feedback, and 24V DC brake power with Kinetix VP motors. Feedback conductors are wired to the 2198-KITCON-DSL feedback connector kit.
Bulletin 2090 single cable for motor power, feedback, and 24V DC brake power with Kinetix VP motors. 2090-CSxM1DG cables have flying-lead feedback conductors for connection to a customer-supplied 2198-KITCON-DSL feedback connector kit.
Bulletin 2090 standard and continuous-flex feedback cables that include additional conductors for use with incremental and EnDat encoders.
Bulletin 2198 three-phase AC line filters are required to meet CE and are available for use with DC-bus power supplies. Use 2198-DBxx-F filters as field replacements in existing installations that use DC-bus power supplies with inverter ground jumpers installed. Select 2198-DBRxx-F filters for all new systems and remove all inverter ground jumpers.
Bulletin 2198 three-phase AC line filters are required to meet CE and available for use with DC-bus power supplies and regenerative bus supplies. Select 2198-DBRxx-F filters for all new systems and remove all inverter ground jumpers.
Bulletin 1321 line reactors help keep equipment running longer by absorbing many of the power line disturbances that can shut down your power supply. For 2198-RPxxx regenerative bus supplies, line reactors can significantly reduce the amount of circulating currents between the integrated LC filter and other devices on the common AC power source.
The AC three-phase contactor control string must be wired in series with the contactor-enable relay at the CED connector to make sure that three-phase power is removed under various fault conditions to protect the power supply.
Bulletin 2198 external passive-shunt resistors for use when the DC-bus power supply internal shunt capability is exceeded. Not for use with regenerative bus supplies.
External active shunts from Rockwell Automation Encompass™ partner, Powerohm Resistors, Inc., are available for connecting to Bulletin 2198 DC-bus power supplies and regenerative bus supplies. See External Active-shunt
Connections on page 183 for catalog numbers.
18 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Start Chapter 1
Bulletin 2198
Shunt Module
(optional component)
Magnetic Contactor (M1) Control String
1606-XLxxx
24V DC Control, Digital Inputs,
and Motor Brake Power (customer-supplied)
AC Input Power
Kinetix 5700 Servo Drive System
(front view)
Bulletin 2198 shared-bus connection system for DC-bus and 24V DC control power.
Kinetix 5700 Servo Drive System (top view)
Line Disconnect
Device
324…528V AC
Three-phase Input Power
Circuit
Protection
Magnetic (M1)
Contac tor
Bonded Cabinet Ground Bus
2198-DBRxx-F
AC Line Filter
(required for CE)
Converter Digital Inputs
Inverter Digital Inputs
Shared DC-bus Power
Shared 24V Control Power (24V shared-bus connection system is optional)
DC-bus
Power Supply
Single-axis
Inverter
Dual-axis Inverters
Capacitor
Module

DC-bus Power Supply Input Power Configurations

A single 2198-Pxxx DC-bus (converter) power supply can supply the Kinetix 5700 drive system with 458…747V shared DC-bus power (7…46 kW). For additional output power (kW) you can install two or three 2198-P208 DC-bus power supplies. You can also extend the DC-bus to additional inverter clusters via accessory modules.

Typical DC-bus Power Supply Configuration Example

In this multi-axis example, AC input power is fed to the DC-bus (converter) power supply. One single-axis (inverter) module and two dual-axis (inverter) modules support five axes of motion. The DC-bus power supply is mounted on the far left and the inverters are positioned on the right, but the reverse mounting order (right to left) is also possible.
Digital inputs are wired to sensors and the control circuitry at the IOD connectors. The contactor-enable relay protects the DC-bus power supply in the event of shutdown fault conditions.
Figure 1 - Typical DC-bus Power Supply Installation
SH
DC+
Allen-Bradley
1606-XL
Power Supply
Input
19
SB+/NC S1A SCA S2A SB­NC NC
NC
16
8
19
19
SB+/NC
SB+/NC
S1A
S1A
SCA
SCA
S2A
S2A
SB-
SB-
NC
NC
NC
NC
NC
NC
16
16
8
8
MOD
MOD
NET
MOD
NET
MOD
NET
MOD
NET
DC BUS
2
1
I/O
1
6
5
10
UFB
D+ D-
MF
-
MBRK
+
2
1
1
4
I/O
2
2
1
1
I/O-A
I/O-B
I/O-A
I/O-B
1
6
1
6
1
6
1
6
MODULE
D+ D-
510
UFB-A UFB-B
510
D+ D-
STATUS
510
510
UFB-A UFB-B
D+D-D+
D-
MF-A MF-B MF-A MF-B
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 19
Chapter 1 Start
DC+
SH
DC+
SH
1606-XL
Power Supply
Input
Allen-Bradley
MOD
NET
MOD
NET
MOD
NET
2
1
1
4
I/O
2
1
2
1
UFB-A UFB-B
UFB-A UFB-B
D+D-D+
D-
D+ D-
MF-A MF-B MF-A MF-B
D+ D-
DC+
SH
MOD
NET
2
1
1
4
I/O
MOD
NET
2
1
1
4
I/O
MOD
DC BUS
MODULE
STATUS
19
8
16
19
8
16
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
SB+/NC
NC
S1A SCA S2A SB­NC NC
SB+/NC
NC
S1A SCA S2A SB­NC NC
MOD
NET
2
1
1
I/O
6
5
10
MBRK
+
-
21mm (4 AWG-250 kcmil) 15-20 Nm (132-177 lbin)
2
W V U
19
8
16
SB+/NC
NC
S1A SCA S2A SB­NC NC
Bulletin 2198
Shunt Module
(optional component)
1606-XLxxx
24V DC Control Power
(customer-supplied)
AC Input Power
Kinetix 5700 Ser vo Drive System
(front view)
Kinetix 5700 Servo Drive System (top view)
Circuit
Protection
Bonded Cabinet
Ground Bus
1321-3R80-B Line Reactors
(required components)
2198-P208 DC-bus Power Supplies
Single-axis Inverter
Dual-axis Inverters
Capacitor
Module
Bulletin 2198 shared-bus connection system for DC-bus and 24V DC control power.
Shared DC-bus Power
Shared 24V Control Power (24V shared-bus connection system is optional)
Magnetic Contactor
(M1) Control String
Line Disconnect
Device
324…528V AC
Three-phase Input Power
Magnetic (M1)
Contac tor
2198-DBR200-F
AC Line Filter
(required for CE)
Circuit
Protection

Multiple DC-Bus Power Supply Configuration Example

In this example, three DC-bus (converter) power supplies all receive AC input power and feed the inverter modules for increased output power.
Contactor enable relays from each of the DC-bus power supplies are wired in series to protect the DC-bus power supply in the event of shutdown fault conditions.
Figure 2 - Multiple DC-bus Power Supply Installation
IMPORTANT When two or three DC-bus power supplies are wired together in the same
drive cluster, they must all be catalog number 2198-P208.
20 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Start Chapter 1
Kinetix 5700 Servo Drives
Cluster 1 (front view)
Bonded Cabinet
Ground Bus
Kinetix 5700 Extended Servo Drives
Cluster 2 (front view)
DC-bus Extension
Shared DC-bus and 24V DC Control Power
Circuit
Protection
1321-3R80-B Line Reactors
(required components)
2198-P208 DC-bus Power Supplies
Single-axis
Inverter
Dual-axis
Inverters
Capacitor
Module
Extension
Module
Capacitor
Module
Extension
Module
Dual-axis Inverters
Bulletin 2198 Shared-bus
Connection System
(24V shared-bus connection
system is optional)
Magnetic Contactor
(M1) Control String
Line Disconnect
Device
324…528V AC
Three-phase Input Power
Magnetic (M1)
Contac tor
2198-DBR200-F
AC Lin e Filter
(required for CE)
DC-bus Extension
ATT EN TI ON : Circuit protection can
be added after the power supply cluster to help protect converters and inverters from damage in the event of
a DC-bus cable short-circuit.
Circuit
Protection

Extended DC-bus Configuration Example

In this example, two drive clusters in the same cabinet are connected by the same 458…747V DC bus voltage. Kinetix 5700 accessory modules provide connection points for the DC-bus at the end of cluster 1 and the beginning of cluster 2. The Kinetix 5700 servo drive system is capable of up to 208 A DC-bus current. Two accessory modules are needed when the DC-bus system current exceeds 104 A. See Accessory Module Selection information on the when accessory modules are required.
Figure 3 - Extended DC-bus Installation
MOD
MOD
MOD
MOD
MOD
MOD
NET
NET
NET
DC BUS
NET
MOD
NET
NET
on page 59 for more
MOD
NET
MOD
NET
2
1
1
4
I/O
MOD
NET
2
1
1
4
I/O
2
2
1
1
I/O-A
I/O-B
I/O-A
1
6
1
6
1
MODULE
510
510
510
STATUS
UFB-A UFB-B
UFB-A UFB-B
D+
D+
D-
D-
MF-A MF-B
MF-A MF-B MF-A MF-B
MOD
NET
2
1
1
4
I/O
2
2
1
I/O-B
6
1
510
D+ D-
1
I/O-A
I/O-B
I/O-A
6
1
6
1
6
1
6
1
510
510
510
510
UFB-A UFB-B
UFB-A UFB-B
D+
D+
D+
D+
D-
D-
D-
D-
MF-A MF-B
I/O-B
6
2
1
I/O-A
I/O-B
1
6
1
6
510
510
UFB-A UFB-B
D+D-D+
D+
D-
D-
MF-A MF-B MF-A MF-B
2
1
1
510
I/O-A
UFB-A UFB-B
2
1
I/O-B
I/O-A
I/O-B
6
1
6
1
6
1
6
510
510
510
UFB-A UFB-B
D+
D+
D+
D-
D-
D-
MF-A MF-B
MOD
NET
2
1
I/O-A
I/O-B
1
6
1
6
510
510
UFB-A UFB-B
D+D-D+
D-
MF-A MF-B MF-A MF-B
D+ D-
2
1
1
510
I/O-A
UFB-A UFB-B
MOD
NET
I/O-B
6
1
6
510
D+ D-
MOD
DC BUS
MODULE
STATUS
MOD
NET
2
1
I/O
1
6
5
10
UFB
D+ D-
MF
-
MBRK
+
IMPORTANT When two or three DC-bus power supplies are wired together in the same
drive cluster, they must all be catalog number 2198-P208.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 21
Chapter 1 Start
2
1
16
I/O
510
iPS RDY
+
MOD–
NET–
1 2 3 4 5
6 7 8 9 10
MOD
NET
2
1
1
4
I/O
2
1
16
I/O
510
iPS RDY
+
MOD–
NET–
1 2 3 4 5
6 7 8 9 10
SH
DC+
1606-XL
Power Supply
Input
Allen-Bradley
Bulletin 2198
Shunt Module
(optional component)
Magnetic Contactor
(M1) Control String
1606-XLxxx
24V DC Control, Digital Inputs,
and iTRAK Motor Module Control Power
(customer-supplied)
AC Input Power
Kinetix 5700 iTRAK System
(front view)
Kinetix 5700 iTRAK System (top view)
Line Disconnect
Device
324…528V AC
Three-phase
Input Power
Circuit
Protection
Magnetic (M1)
Contac tor
Bonded Cabinet
Ground Bus
2198-DBRxx-F
AC Lin e Filter
(can be required for CE)
Converter Digital Inputs
iTRAK Motor Modules
DC-bus
Power Supply
iTRAK
Power Supply
iTRAK
Power Supp ly
iTRAK Motor Modules
iTRAK Power Supply Digital Inputs
Shared-bus connection system for DC-bus and 24V DC control power.
Shared DC-bus Power
Shared 24V Control Power
(1)
(24V shared-bus connection system is optional)
2198T-CHBFLS8
Motor Power
Cables

iTRAK Power Supply Configuration Example

In this example, AC input power is fed to the DC-bus (converter) power supply. Two iTRAK power supplies support up to 40 iTRAK motor modules, depending on cable lengths and iTRAK motor-module power consumption.
Digital inputs are wired to sensors and the control circuitry at the IOD connectors. The contactor-enable relay protects the DC-bus power supply in the event of shutdown fault conditions.
Figure 4 - Typical iTRAK Power Supply Installation
(1) If total control power current exceeds 16 A, a second input connector (catalog number 2198T-W25K-P-IN) can be added to the
leftmost iTRAK power supply.
22 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Start Chapter 1
1606-XL
Power Supply
Input
Allen-Bradley
MOD
NET
MOD
NET
MOD
NET
1
I/O
6
5
10
2
1
2
1
2
1
1
I/O-A
6
510
1
I/O-B
6
510
UFB
UFB-A UFB-B
UFB-A UFB-B
D+D-D+
D-
D+ D-
MF-A MF-B MF-A MF-B
D+ D-
MBRK
+
-
DC+
D+ D-
MF
SB+/NC
NC
19
8
16
19
8
16
19
8
16
1
I/O-A
6
510
1
I/O-B
6
510
S1A SCA S2A SB­NC NC
SB+/NC
NC
S1A SCA S2A SB­NC NC
SB+/NC
NC
S1A SCA S2A SB­NC NC
MOD
NET
2
1
1
I/O
6
5
10
OK+
OK–
EN–
EN+
DC–
MOD
DC BUS
MODULE
STATUS
MOD
NET
2
1
UFB-A UFB-B
D+ D-
MF-A MF-B
D+ D-
1
I/O-A
6
510
1
I/O-B
6
510
19
8
16
SB+/NC
NC
S1A SCA S2A SB­NC NC
Active Shunt (optional component)
See External Active-shunt Connections
on page 183
for more information.
Magnetic Contactor (M1) Control String
1606-XLxxx
24V DC Control, Digital Inputs, and
Motor Brake Power (customer-supplied)
AC Input Power
Kinetix 5700 Servo Drive System
(front view)
Shared-bus connection system for DC-bus and 24V DC control power.
Kinetix 5700 Ser vo Drive System (top view)
Line Disconnect
Device
324…506V AC
Three-phase Input Power
Circuit
Protection
Magnetic (M1)
Contac tor
Bonded Cabinet Ground Bus
Converter Digital Inputs
Inverter Digital Inputs
Shared DC-bus Power
Shared 24V Control Power (24V shared-bus connection system is optional)
Single-axis
Inverter
Dual-axis Inverters
Regenerative Bus Supply
(1)
DC-bus Conditioner Module
2198-DBRxx-F
AC Lin e Filter
(required for CE)

Regenerative Bus Supply Input Power Configurations

The 2198-RPxxx regenerative bus supply (24…140 kW) provides full-line motoring and regenerative power to and from the Kinetix 5700 drive system. In addition, you can extend the DC-bus voltage to additional inverter clusters via accessory modules.

Typical Regenerative Bus Configuration Examples

In this example, the inverter modules are mounted to the right of the regenerative bus supply. One single-axis (inverter) module and three dual-axis (inverter) modules support seven axes of motion. Other features include:
• Digital inputs are wired to sensors and the control circuitry at the IOD connectors.
• The contactor enable relay protects the regenerative bus supply in the event of shutdown fault conditions.
• The DC-bus conditioner module is required when the combined motor cable length exceeds 400 m (1312 ft). See Accessory Module Selection on page 59
Figure 5 - Typical Shared DC-bus Installation (mounted left to right)
for more information on accessory module requirements.
(1) The regenerative bus supply can be left or right of the inverters. Further, we recommend that the highest inverter power ratings
are positioned closest to the regenerative bus supply and in decreasing order leading away from the regenerative bus supply.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 23
Chapter 1 Start
19
8
16
SB+/NC
NC
S1A SCA S2A SB­NC NC
1606-XL
Power Supply
Input
Allen-Bradley
MOD
NET
2
1
1
I/O
6
5
10
MBRK
+
-
21mm (4 AWG-250 kcmil) 15-20 Nm (132-177 lbin)
2
W V U
MOD
NET
2
1
1
I/O
6
5
10
MOD
NET
2
1
UFB-A UFB-B
D+ D-
MF-A MF-B
D+ D-
MODULE STATUS
MOD
DC BUS
1
I/O-A
6
510
1
I/O-B
6
510
19
8
16
SB+/NC
NC
S1A SCA S2A SB­NC NC
L1 L2 L3
19
8
16
SB+/NC
NC
S1A SCA S2A SB­NC NC
MOD
NET
UFB-A UFB-B
D+ D-
MF-A MF-B
D+ D-
I/O-A
6101
I/O-B
6
510
21mm (4 AWG-250 kcmil) 15-20 Nm (132-177 lbin)
2
1606-XLxxx
24V DC Control Power
(customer-supplied)
AC Input Power
Kinetix 5700 Servo Drive System
(front view)
Kinetix 5700 Servo Drive System (top view)
Line Disconnect Device
324…506V AC
Three-phase
Input Power
Circuit Protection
Magnetic (M1)
Contactor
Bonded Cabinet
Ground Bus
2198-DBRxx-F
AC Line Filter
(required for CE)
Shared DC-bus Power
Shared 24V Control Power
Dual-axis Inverters
Regenerative Bus Supply
(1)
DC-bus Conditioner
Module
24V DC Control Power Connector Plug
Single-axis Inverter
Magnetic Contactor (M1) Control String
1321-3Rxx-x Line Reactor
(recommended)
In this example, the 2198-RP312 regenerative bus supply is mounted on the far right and followed by the 2198-S312-ERSx single-axis inverter, and two 2198-D020-ERSx dual-axis inverters.
• The 2198-BARCON-440DC200 DC-bus link extends the DC-bus from the regenerative bus supply to the single-axis inverter.
• The 2198-BARCON-220DC200 DC-bus link extends the DC-bus from the single-axis inverter to the dual-axis inverter.
• The regenerative bus supply has 24V DC wired to the connector plug
• The 2198-xxxx-P-T bus-bar connector extends 24V control power from the input wire connector to the dual-axis and single-axis inverters.
• The DC-bus conditioner module is required when the combined motor cable length exceeds 400 m (1312 ft). See Accessory Module Selection on page 59
Figure 6 - Typical Shared DC-bus Installation (mounted right to left)
for more information on accessory module requirements.
24 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
(1) The regenerative bus supply can be left or right of the inverters. Further, we recommend that the highest inverter power ratings
are positioned closest to the regenerative bus supply and in decreasing order leading away from the regenerative bus supply.
Start Chapter 1
MOD
NET
2
1
1
I/O-A
6
510
1
I/O-B
6
510
UFB-A UFB-B
D+D-D+
D-
MF-A MF-B
MOD
NET
2
1
1
I/O
6
5
10
OK+
OK–
EN–
EN+
MOD
NET
2
1
1
I/O-A
6
510
1
I/O-B
6
510
UFB-A UFB-B
D+D-D+
D-
MF-A MF-B
MOD
NET
2
1
1
I/O
6
5
10
OK+
OK–
EN–
EN+
MOD
NET
2
1
1
4
I/O
MOD
NET
2
1
UFB-A UFB-B
D+D-D+
D-
MF-A MF-B
1
I/O-A
6
510
1
I/O-B
6
510
Kinetix 5700 Servo Drive Systems
(front view)
Line Disconnect
Device
324…506V AC
Three-phase Input Power
Circuit
Protection
Magnetic (M1)
Contac tors
Bonded Cabinet
Ground Bus
2198-DBRxx-F
AC Line Filter
(required for CE)
Dual-axis
Inverter
Regenerative Bus Supply
DC-bus
Power Supply
Dual-axis
Inverter
Regenerative Bus Supply
Dual-axis
Inverter
Bulletin 1321 Line Reactors
Additional
Inverters
Additional
Inverters
Additional
Inverters
M1 Control
String
Magnetic Contactor (M1)
Control S tring
M1 Control
String
Circuit
Protection
2198-DBRxx-F AC Line Filter
(required for CE)
2198-DBRxx-F
AC Line Filter
(required for CE)
In this example, three-phase input power feeds two 2198-RPxxx regenerative power supplies and one 2198-Pxxx DC-bus power supply.
IMPORTANT We recommend that Bulletin 1321 line reactors be used in any system with
multiple regenerative bus supplies sharing the same AC input-power source.
Bulletin 1321 line reactors are used in the regenerative power supply input power circuits to help do the following:
• Reduce circulating currents between different systems
• Prevent all power supplies on the same input power source from nuisance thermal overload faults
Figure 7 - Input Power to Multiple Kinetix 5700 Drive Systems
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 25
Chapter 1 Start
MOD
NET
2
1
UFB-A UFB-B
D+ D-
MF-A MF-B
MOD
NET
2
1
UFB-A UFB-B
D+ D-
MF-A MF-B
D+ D-
MOD
NET
2
1
D+ D-
MF-A MF-B
D+ D-
MOD
NET
MOD
NET
MOD
NET
2
1
2
1
2
1
UFB
UFB-A UFB-B
UFB-A UFB-B
D+D-D+
D-
D+ D-
MF-A MF-B MF-A MF-B
D+ D-
MBRK
+
-
MOD
NET
D+ D-
MF
MODULE
STATUS
MOD
NET
MODULE
STATUS
MOD
NET
2
1
UFB-A UFB-B
D+ D-
MF-A MF-B
D+ D-
MOD
NET
MODULE
STATUS
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O
6
5
10
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
MOD
NET
2
1
1
I/O
6
5
10
OK+
OK–
EN–
EN+
Kinetix 5700 Drive System
Cluster 1 (front view)
Kinetix 5700 Extended Drive System
Cluster 2 (front view)
DC-bus Extension
Shared DC-bus and 24V DC Control Power
Magnetic Contactor
(M1) Control String
Dual-axis Inverters
Dual-axis Inverters
Line Disconnect Device
324…506V AC
Three-phase Input Power
Circuit Protection
Magnetic (M1) Contac tor
Bonded Cabinet
Ground Bus
2198-DBRxx-F
AC Line Filter
(required for CE)
Regenerative Bus Supply
2198-CAPMOD-DCBUS-IO Extension Module
2198-CAPMOD-2240 Capacitor Module
2198-CAPMOD-2240 Capacitor Module
2198-DCBUSCOND-RP312 DC-bus Conditioner Module
Combin ed motor
cable lengths equal
300 m (984 ft).
Combined motor
cable lengths equal
480 m (1575 ft).
Single-axis
Inverter
ATTENTION: Circuit protection can
be added after the power supply cluster to help protec t converters and inverters from damage in the event of
a DC-bus cable short-circuit.
Bulletin 1321
Line Reactor
(recommended)

Extended Regenerative Bus Configuration Example

In this example, two drive clusters in the same cabinet are connected by the same 458…747V DC bus voltage.
• Kinetix 5700 accessory modules provide connection points for the DC bus at the end of cluster 1 and the beginning of cluster 2.
• The Kinetix 5700 servo drive system is capable of up to 208 A DC-bus current. Two parallel accessory modules are needed when the DC-bus system current exceeds 104 A.
• The DC-bus conditioner module is required when the combined motor cable length exceeds 400 m (1312 ft). See Accessory Module
Selection on page 59 for more information on accessory module
requirements.
Figure 8 - Extended DC-bus Installation
26 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
2
1
16
I/O
510
iPS RDY
+
MOD–
NET–
1 2 3 4 5
6 7 8 9
10
2
1
16
I/O
510
iPS RDY
+
MOD–
NET–
1 2 3 4 5
6 7 8 9
10
1606-XL
Power Supply
Input
Allen-Bradley
DC+
MOD
NET
2
1
1
I/O
6
5
10
OK+
OK–
EN–
EN+
DC–
Magnetic Contactor
(M1) Control String
1606-XLxxx
24V DC Control, Digital Inputs,
and iTRAK Motor Module Control Power
(customer-supplied)
AC Input Power
Kinetix 5700 iTRAK System
(front view)
Kinetix 5700 iTRAK System (top view)
Line Disconnect Device
324…506V AC
Three-phase Input Power
Circuit Protection
Magnetic (M1) Contac tor
Bonded Cabinet
Ground Bus
Converter Digital Inputs
iTRAK Motor Modules
Regenerative Bus Supply
iTRAK
Power S upply
iTRAK
Power S upply
iTRAK Motor Modules
iTRAK Power Supply Digital Inputs
Bulletin 2198 shared-bus connection system for DC-bus and 24V DC control power.
Shared DC-bus Power Input
Shared 24V Control Power Input (24V shared-bus connection system is optional)
2198T-CHBFLS8
Motor Power
Cables
Active Shunt (optional component)
See External Active-shunt Connections
on page 183
for more information.
Bulletin 1321
Line Reactor
(recommended)
2198-DBRxx-F
AC Lin e Filter
(can be required for CE)
Start Chapter 1

iTRAK Power Supply Configuration Example

In this example, AC input power is fed to the regenerative bus supply. Two iTRAK power supplies support up to 40 iTRAK motor modules, depending on cable lengths and iTRAK motor-module power consumption.
Digital inputs are wired to sensors and the control circuitry at the IOD connectors. The contactor-enable relay protects the regenerative bus supply in the event of shutdown fault conditions.
Figure 9 - Typical iTRAK Power Supply Installation
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 27
Chapter 1 Start
1606-XL
Power Supply
Input
Allen-Bradley
MOD
NET
MOD
NET
MOD
NET
2
1
2
1
2
1
UFB
UFB-A UFB-B
UFB-A UFB-B
D+D-D+
D-
D+ D-
MF-A MF-B MF-A MF-B
D+ D-
MBRK
+
-
R
E
G
E
N
E
R
A
T
IV
E
P
O
W
E
R
S
U
P
P
LY
R
E
G
E
N
E
R
A
T
IV
E
P
O
W
E
R
S
U
P
P
L
Y
87208720
MCMC
RST
PRG
ENT
READYREADY
FAULTFAULT
PROGRAMPROGRAM kWkW
V
A
MOD
NET
2
1
UFB-A UFB-B
D+ D-
MF-B
D+ D-
MOD
DC BUS
MODULE STATUS
D+ D-
MF
19
8
16
19
8
16
19
8
16
1
I/O
6
5
10
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
SB+/NC
NC
S1A SCA S2A SB­NC NC
SB+/NC
NC
S1A SCA S2A SB­NC NC
SB+/NC
NC
S1A SCA S2A SB­NC NC
MOD
DC BUS
MODULE STATUS
1606-XLxxx
24V DC Control, Digital Inputs,
and Motor Brake Power (customer-supplied)
AC Input Power
Kinetix 5700 Servo Drive System (front view)
Kinetix 5700 Servo Drive System (top view)
324…506V AC
Three-phase Input Power
Circuit Protection
Magnetic
(1)
(M1) Contactor
Bonded Cabinet Ground Bus
8720MC-RFI80
AC Lin e Filter
(required for CE)
8720MC-LRxx
Line Reactor
8720MC-RPS065-BM-HV2
Regenerative Power Supply
Single-axis
Inverter
Dual-axis Inverters
Capacitor
Module
8720MC-HF-B2 Harmonic Filter
8720MC-VA-B
Vari sto r
Bulletin 2198 shared-bus connection system for DC-bus and 24V DC control power.
Shared DC-bus Power Input
Shared 24V Control Power Input (24V shared-bus connection system is optional)
DC-bus
Conditioner
Module

8720MC-RPS Power Supply Input Power Configuration

In this example, three-phase AC input power is fed to the Bulletin 8720MC regenerative power supply. The 8720MC-RPS DC-bus voltage supplies the Kinetix 5700 DC-bus via the capacitor module.
• The 8720MC-RPS065 provides 65 A of DC-bus current. The 2198­CAPMOD-2240 capacitor module and 2198-DCBUSCOND-RP312 DC-bus conditioner are required to reduce voltage stress on the system components.
• If the 8720MC-RPS190 is used, the capacitor module and DC-bus conditioner module provide up to 208 A of DC input current. DC-bus full-regeneration is possible with this configuration.
• The DC-bus conditioner module is required when the combined motor cable length exceeds 400 m (1312 ft). See Accessory Module Selection on page 59
for more information on accessory module requirements.
IMPORTANT The 8720MC-RPS power supply is not compatible with the iTRAK power
supply.
Figure 10 - 8720MC-RPS Power Supply Installations
28 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
(1) This M1 contactor is controlled by the 8720MC regenerative power supply.
Start Chapter 1
2090-CSBM1DE Single Motor Cables
2198-KITCON-DSL Connector Kit
Accepts DSL motor feedback from VPC-Bxxxxx-Q and (Bulletin VPL, VPF, VPS) rotary motors and Kinetix VP electric cylinders.
Bulletin 2090 Motor Power and Feedback Cables
2198-K57CK-D15M Universal Connector Kit
Accepts multiple encoder feedback types:
• Hiperface high-resolution absolute multi-turn and single-turn encoders – VPC-Bxxxxx-S rotary motors – MP-Series (Bulletin MPL, MPM, MPF, MPS) rotary motors – HPK-Series asynchronous rotary motors – MP-Series (Bulletin MPAS, MPAR, MPAI) linear actuators – LDAT-Series linear thrusters, LDC-Series linear motors
• Heidenhain EnDat high-resolution absolute encoders – VPC-Bxxxxx-Y rota ry motors – RDD-Series direct-drive motors
• Feedback-only, master feedback, or load feedback
(absolute single-turn/multi-turn Hiper face)
• Feedback-only, master feedback, or load feedback (incremental)
MP-Series Rotary Motors (MPL-Bxxxx motor is shown)
LDAT-Series Linear Thrusters
2198-H2DCK Converter Kit
Converts 15-pin Hiperface feedback into 2-pin DSL feedback for:
• VPC-Bxxxxx-S rotary motors
• MP-Series rotary motors and linear actuators
• HPK-Se ries asynchro nous rotary motor s
• LDAT-Series linear thrusters
• Feedback-only, master feedback, or load feedback (absolute single-turn/multi-turn Hiperface)
15-pin Universal Feedback (UFB) Connectors
2-pin Motor Feedback (MF) Connectors
2198-Dxxx-ERSx
or 2198-Sxxx-ERSx Inverters
(2198-Dxxx-ERSx dual-axis
inverter is shown)
Kinetix VP Rotary Motors (Bulletin VPL, VPF, VPS and Catalog Number VPC-Bxxxxx-Q)
HPK-Series Asynchronous Rotary Motors
and Induction Rotary Motors
(closed-loop control)
2090-CSBM1DG Single Motor Cables
RDD-Series Direct Drive Rotary Motors
Kinetix VP Rotary Motors
Catalog Numbers
VPC-Bxxxxx-S and VPC-Bxxxxx-Y
Kinetix VP Electric Cylinders (Bulletin VPAR)
MP-Series (Bulletin MPAS)
Integrated Linear Stages
MP-Series (Bulletin MPAI) Heavy-duty Electric Cylinders
LDC-Series
Linear Motors
MP-Series (Bulletin MPAR)
Electric Cylinders

Motor and Auxiliary Feedback Configurations

UFB-A
D+D-D+
MF-A
UFB-A
D+D-D+
MF-A
Feedback connections are made at the 2-pin motor feedback (MF) connector and the 15-pin universal feedback (UFB) connector. These examples illustrate how you can use the Bulletin 2198 connector kits for making these connections. To see motor power and brake connections, refer to Chapter 5
page 127
Figure 11 - Feedback Configuration Example
UFB-A
MOD–
NET–
2
1
I/O-B
I/O-A
16
1
6
510
510
UFB-A
UFB-B
D+D-D+
D-
MF-B
MF-A
D+D-D+
MF-A
UFB-B
D-
MF-B
UFB-B
D-
MF-B
UFB-B
D+D-D+
D-
MF-B
MF-A
UFB-A
UFB-B
D-
MF-B
on
.
m
o c . b a . w
A
S w U w N I E D A M
0 0 5
X 5
X 7
X 0 X M
­X
C
X
D
X
L
X
. X O . N O .
T
N
A
L
C
A
I R E S
A
ES I R E S
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 29
Chapter 1 Start
ControlLogix 5570 Controller with Bulletin 1756 EtherNet/IP Module
Studio 5000 Logix Designer Application
1585J-M8CBJM-x
Ethernet (shielded) Cable
1734-AENTR POINT I/O™ EtherNet/IP Adapter
ControlLogix Controller Programming Network
PanelView™ Plus
Display Terminal
1585J-M8CBJM-OM15
0.15 m (6 in.) Ethernet cables for drive-to-drive connections.
Kinetix 5700 Servo Drive System
2198-ABQE
Encoder Output Module
Line Scan Cameras

Typical Communication Configurations

The Kinetix 5700 drives support any Ethernet topology including linear, ring, and star by using ControlLogix, GuardLogix, or CompactLogix controllers.
These examples feature the ControlLogix 5570 programmable automation controllers with support for integrated motion and integrated safety over the EtherNet/IP network. Other Allen-Bradley controllers are also compatible with the Kinetix 5700 servo drives.
Refer to ControlLogix Communication Module Specifications Technical Data, publication 1756-TD003
, for more information on ControlLogix
1756-EN2T, 1756-EN2TR, and 1756-EN3TR communication modules.
TIP These example configurations use the 2198-Pxxx DC-bus power supply.
However, 2198-RPxxx regenerative bus supply can be used instead.

Linear Topology

In this example, all devices are connected by using linear topology. The Kinetix 5700 drive modules include dual-port connectivity, however, if any device becomes disconnected, all devices downstream of that device lose communication. Devices without dual ports must include the 1783-ETAP module or be connected at the end of the line.
Figure 12 - Kinetix 5700 Linear Communication Installation
EtherNet/IP
LNK1LNK2NET OK
2
1
MOD
MOD
NET
OUTPUT-A OUTPUT-B
NET
2
1
1
4
I/O
MOD
MOD
MOD
NET
NET
MOD
NET
NET
2
1
I/O
1
6
5
10
UFB
-
MBRK
+
2
2
1
1
I/O-A
I/O-B
I/O-A
1
6
1
6
1
6
1
510
510
510
510
UFB-A UFB-B
UFB-A UFB-B
D+
D+D-D+
D+
D-
D-
D-
MF-A MF-B MF-A MF-B
2
1
I/O-B
I/O-A
I/O-B
6
1
6
1
510
D+ D-
UFB-A UFB-B
MF-A MF-B
510
D+ D-
6
1734-AENTR
02
0
POINT I O
Module Status
Network Activity
Network Status
Point Bus Status
Link 1 Activity/
System
Status
Power
Field Power
Link 2 Activity/ Status
30 Rockwell Automation Publication 2198-UM002G-EN-P - February 2019