Installation Instructions
20-750-APS
20-750-S
20-750-S1
20-750-2262C-2R
20-750-2263C-1R2T
20-750-2262D-2R
20-750-1132C-2R
20-750-1133C-1R2T
20-750-1132D-2R
20-750-ENC-1 20-750-DENC-1
20-750-UFB-1
20-750-ATEX
IMPORTANT: When a Safe Speed Monitor option
(20-750-S1) is used with a Dual Incremental Encoder
option (20-750-DENC-1) both modules must be
installed on the same backplane (ports 6, 5, 4).
IMPORTANT: Only one safety option module can be
installed at a time. Multiple safety options or duplicate
safety option installations are not supported.
PowerFlex 750-Series Option Modules
These instructions cover the installation of the option modules listed below.
For instructions on installing Network Communication option modules, refer to publication 750COM-IN002
Compatible Ports
PowerFlex 753 Drives PowerFlex 755 Drives
Option Module
Cat. No. 20-750-
APS See Page 2 See Page 2 See Page 2 Yes No No No No
2262C-2R, 2263C-1R2T, 2262D-2R No Ye s Ye s Yes Ye s Ye s No Yes Ye s Ye s Yes Ye s Ye s Yes
1132C-2R, 1133C-1R2T, 1132D-2R No Ye s Ye s Yes Ye s Ye s No Yes Ye s Ye s Yes Ye s Ye s Yes
1132C-2R, 1133C-1R2T, 1132D-2R
with 20-750-ATEX installed
ENC-1 No Ye s Ye s Yes Ye s Ye s No Yes Ye s Ye s Yes Ye s Ye s Yes
UFB-1 Not Supported No Ye s Ye s No No Yes Ye s Ye s
S Yes Ye s Ye s Yes Ye s Ye s Ye s Yes Ye s Ye s Yes Ye s Ye s Yes
(2)
S1
(2)
DENC-1
(1) For detailed instructions on installation of 11-Series I/O with the ATEX option module, refer to the PowerFlex 750-Series ATEX User Manual, publication 750-UM003.
(2) See Using 20-750-S1 with 20-750-DENC-1.
(1)
Frame 1 Ports Frame 2…7 Ports Frame 1 Ports Frame 2…10 Ports
No Ye s Ye s No Yes Ye s No Ye s Yes No No No Yes Ye s
Yes Ye s Ye s Yes Ye s Ye s Ye s Yes Ye s No No Yes Ye s Ye s
No Ye s Ye s Yes Ye s Ye s No Yes Ye s Ye s Yes Ye s Ye s Yes
.
Option Module Installation Using 20-750-S1 with 20-750-DENC-1
0.45 N•m (4.0 lb•in)

www.rockwellautomation.com
Americas: Rockwell Automation, 1201 South Second Street,
Milwaukee, WI 53204-2496 USA,
Tel:
(1) 414.382.2000, Fax: (1) 414.382.4444
Europe
/
Middle East/Africa: Rockwell Automati
on,
Pegasus Park, De Kleetlaan 12a,
1831 Diegem, Belgium,
Tel: (32) 2 663 0600, Fax: (32) 2 663 0640
Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846
Power, Control and Information Solutions Headquarters
Auxiliary Power Supply (20-750-APS) Installation
Detail A
Profibus Option
Module
A connector cable is provided with Auxiliary Power Supply option module for use in PowerFlex 753 Drives and in
PowerFlex 755 Frame 1 drives. The cable is used to connect the module to the backplane when installed on the upper
control pod brackets.
IMPORTANT: Do not use the Auxiliary Power Supply option module with Frame 8 and larger drives. Refer to the
PowerFlex 750-Series AC Drives Installation Instructions, publication 750-IN001
external power supply to Frame 8 and larger drives.
for information on connecting an
Option Module Installation next to a Profibus Option Module
If a PowerFlex 20-750-PBUS Profibus option module resides in the adjacent port
to the right of the port in which the new module is being installed, the lower T15
Torx™ head mounting screw (see Detail A) of the new module may electrically
contact the metal Profibus cable connector attached to the Profibus option
module. This may cause faulty operation. To help prevent this, perform the steps
below. If a PowerFlex 20-750-PBUS Profibus option module is not in that port,
disregard these steps.
1. Remove the lower T15 Torx head mounting screw shown in Detail A,
from the new module being installed.
To remove the captive T15 Torx head screw, the module must be removed
to back the screw out of the mounting clip.
2. Replace the larger T15 Torx head screw with the smaller spare T8 Torx
head mounting screw that was shipped with the PowerFlex 20-750-PBUS
Profibus option module.
U.S. Allen-Bradley Drives Technical Support - Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, E-mail: support@drives.ra.rockwell.com,
Online: www.ab.com/support/abdrives
Publication 750-IN002F-MU-P – April 2015
Supersedes 750-IN002E-MU-P – July 2013 Copyright © 2015 Rockwell Automation, Inc. All rights reserved. Printed in USA.