Allen-Bradley 193-EOS-SDS-BP Installation Manual

Installation Instructions
(Cat 193-EOS-SCS; 193-EOS-SDS)
WARNING: To prevent electrical shock, disconnect from power source before installing or servicing. Follow NFPA 70E requirements. Install in suitable enclosure. Keep free from contaminants. Installation, adjustments, putting into service, use, assembly, disassembly, and maintenance shall be carried out by suitably trained personnel in accordance with applicable code of practice. In case of malfunction or damage, no attempts at repair should be made. The product should be returned to the manufacturer for repair. Do not dismantle the product.
Additional Resources:
1) Go to http://www.literature.rockwellautomation.com; 2) Go to Search. Type in publication number: 193-UM015
Features
Power LED
Trip / Warn LED
Power LED
Trip / Warn LED
Escape
Up
Select
Start Forward / Speed 1
Start Reverse / Speed 2
Local / Remote
Installation
1
1
LOCAL
REMOTE
Stop
LOCAL
REMOTE
Reset
0
RESET
Start Forward / Speed 1
Start Reverse / Speed 2
Local / Remote
Stop
LOCAL
REMOTE
ESC
Reset
SELECT
0
RESET
Enter
Down
193-EOS-SCS 193-EOS-SDS (Requires control module rmware v3.000 or higher)
2
2
1.7 N.m
(15 lb-in)
ESC
SELECT
0
RESET
800F-AW2
3
For use on a at surface of a Type 4X Enclosure
1
Click
2
Copy Cat (read and write complete device congurations
to and from the operator station)
Power LED
ESC
SELECT
LOCAL
REMOTE
0
RESET
Local / Remote
Stop
Read
1) Press for 3 seconds (Local / Remote + Stop)
2) Power LED blinks Red / Green
3) Blinking Green = Successful
4) Blinking Red = Unsuccessful
Power LED
ESC
SELECT
LOCAL
REMOTE
0
RESET
Stop
Reset
Write
1) Press for 3 seconds (Stop + Reset)
2) Power LED blinks Red / Green
3) Blinking Green = Successful
4) Blinking Red = Unsuccessful
Allen-Bradley, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
Diagnostics Specications
Power LED
Blinking Green
Solid Green
Solid Red
Blinking Red
Blinking Red / Green
Trip / Warn LED
Blinking Red
Blinking Yellow
Overload Phase Loss Ground Fault Stall Jam Underload Current Imbalance L1 Under Current L2 Under Current
Current
L3 Under Current L1 Over Current L2 Over Current L3 Over Current L1 Line Loss L2 Line Loss L3 Line Loss
Under Volt L-L Over Volt L-L Voltage Unbalance Phase Rotation Under Frequency
VoltagePowerControlAnalog
Over Frequency
Under Real Pwr Over Real Pwr Under Con kVAR Over Con kVAR Under Gen kVAR Over Gen kVAR Under Power kVA Over Power kVA Under PF Lagging Over PF Lagging Under PF Leading Over PF Leading
Test Trip PTC DLX Operator Station Trip Remote Trip Start Inhibit Hardware Fault Invalid Conguration Option Match Feedback Timeout Expansion Bus Number of Starts Operating Hours Non-Volatile Memory 3 14 Test Mode Trip 3 15
Analog Input11 Analog Input12 Analog Input13 Analog Input21 Analog Input22 Analog Input23 Analog Input31 Analog Input32 Analog Input33 Analog Input41 Analog Input42 Analog Input43
Device Ready Device Active (Current Detected)
Operator Station Error
Communication Error Copy Cat in Progress
Trip Warning
Long Blink Pattern Short Blink Pattern
0 0 0 0 0 0 0 08 0 0 0 0 0 0 0 016
1 1 1 1 1 1
2 2 2 2 2 2 2 28
2 2 2 2
3 3 3 3 3 3 3 38 3 3 3 3 313
4 4 4 4 4 4 4 48
4 4 4 4
IP Rating: IP65
UL Type: Type 4X
Ambient: 55º C Max.
1 2 3 4 5 6 7
9 10 11 12 13 14 15
1
2
3
4
5
6
1
2
3
4
5
6
7
9 10 11 12
1
2
3
4
5
6
7
9 10 11 12
1
2
3
4
5
6
7
9 10 11 12
Publication 193-IN061D-EN-P - September 2014