Allen-Bradley
SLC 500t Modular Hardware Style
Installation
(Cat. Nos. 1747-L511, 1747-L514, 1747-L524, 1747-L531, 1747-L532, 1747-L541, 1747-L542, 1747-L543, 1747-L551, 1747-L552, and 1747-L553)
and Operation Manual
Important User Information
Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards.
The illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication.
Allen-Bradley publication SGI-1.1, Safety Guidelines for the
Application, Installation, and Maintenance of Solid-State Control
(available from your local Allen-Bradley office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication.
Reproduction of the contents of this copyrighted publication, in whole or in part, without written permission of Allen-Bradley Company, Inc., is prohibited.
Throughout this manual we use notes to make you aware of safety considerations:
ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or
!
death, property damage or economic loss.
Attention statements help you to:
identify a hazard
avoid the hazard
recognize the consequences
Important: Identifies information that is critical for successful
application and understanding of the product.
PLC, PLC–2, PLC–3, and PLC–5 are registered trademarks of Rockwell Automation. SLC, SLC 500, SLC 5/01, SLC 5/02, SLC 5/03, SLC 5/04, SLC 5/05, PanelView, PanelView 550, PanelView 900, RediPANEL, ControlView, PBASE, DH+, DTAM, DeviceNet, and Dataliner are trademarks of Rockwell Automation. RSLogix 500 and RSLinx are trademarks of Rockwell Software, Inc. Ethernet is a registered trademark of Digital Equipment Corporation, Intel, and Xerox Corporation. IBM is a registered trademark of International Business Machines, Incorporated. Multimodem is a trademark of Multi–Tech Systems, Inc. Procomm is a registered trademark of Datastorm Technologies, Inc. Tandy is a trademark of the Tandy Corporation. Gateway 2000 is a trademark of Gateway 2000, Inc. Toshiba is a trademark of Toshiba America, Inc. Compaq is a registered trademark of Compaq Computer Corporation. Deskpro is a trademark of Compaq Computer Corporation. Intel is a trademark of Intel Corporation.
6–8
Installing Your Hardware Components
Installing Your Power Supply
If you have multiple chassis configurations, install the chassis interconnect cable before installing the power supply. (See page 6–10.) Also, the power supply terminals accept two #14 AWG wires and are marked as shown in the figure on page 6–8. To install the power supply, do the following:
1. Align the circuit board with the card guide on the left side of the
chassis. Slide the power supply in until flush with the chassis.
Publication
1747-6.2
19524
2. Fasten the power supply to the chassis with the two Phillips head
screws.
3. Place the jumper to match the input voltage. (This does not apply
to 1746-P3 or 1746-P5, which do not have a jumper.)
ATTENTION: Make jumper selection before applying power. Hazardous voltage is present on
!
exposed pins when power is applied.
Installing Your Hardware Components
6–9
Fuse
Jumper Selection
100/120 Volts
200/240 V
Jumper Selection
85–132V ac
170–265V ac
olts
1746-P1 and -P2
POWER
POWER
User Power
User Power
PWR OUT +24V dc
PWR OUT COM 120/240V ac V ac NEUT
CHASSIS GROUND
PWR OUT +24V dc
PWR OUT COMMON
85–132V ac JUMPER 170–265V ac
L185–132/170–265
Fuse
1746-P3
POWER
POWER
User Power
NOT USED NOT USED + 24V dc dc NEUT CHASSIS GROUND
PWR OUT +24V dc PWR OUT COM
+125V dc dc NEUT CHASSIS GROUNDCHASSIS GROUND
L2
NEUTRAL
1746-P4 1746-P5
CHASSIS GROUND
4. Remove the warning label from the top of the power supply.
5. Connect line power to the power supply.
ATTENTION: If you have a 1746-P3, see page 3–5
for special grounding considerations.
!
On the 1746-P1 and -P2 power supply, use the PWR OUT + 24 VDC and PWR OUT COM terminals to power sensors. The terminals provide an isolated, nonfused, 200 mA, 24V dc power supply.
Publication
1747-6.2
6–10
Installing Your Hardware Components
Installing Your Chassis Interconnect Cable
Two cables are available to link modular hardware chassis. Catalog Number 1746-C7 cable is 152.4 mm (6 in.) in length and used when connecting chassis side-by-side. Catalog Number 1746-C9 is
914.4 mm (36 in.) in length and used to link one chassis below the other.
ATTENTION: Do not use any other cables than those provided. Longer cables could affect the integrity of
!
data communications between the chassis, possibly causing unsafe operation. Also, make sure the cable is properly secured to protect against the effects of shock and vibration.
Install the chassis interconnect cable before installing the power supply in multiple chassis configurations.
The cables are “keyed” for proper installation. The end of the cable that plugs into the right socket in the chassis has the “key” on the top of the connector. The opposite end of the cable has the “key” on the inside of the connector for insertion into the expansion chassis.
To remove the cable, move the tabs on the socket outward and the connector pops out.
ATTENTION: The expansion cable must always exit the right end of the chassis with the processor. Refer to
!
the following figures.
C
P
P
S
U
Chassis 1
P S
Chassis 2
CORRECT INSTALLATION
C
P
P
S
U
Chassis 1
P S
Chassis 2
INCORRECT INSTALLATION
C
P
P
S
U
Chassis 1
P S
Chassis 2
INCORRECT INSTALLATION
C
P
P
S
U
Chassis 1
P S
Chassis 2
INCORRECT INSTALLATION
Publication
1747-6.2
Chapter 7
Wiring Your I/O Modules
This chapter describes how to wire your I/O modules. It covers the following:
defining sinking and sourcing
preparing your wiring layout
features of an I/O module
recommendations for wiring I/O devices
wiring your I/O modules
octal label kit installation
using removable terminal blocks
Defining Sinking and Sourcing
Sinking and sourcing are terms used to describe a current signal flow relationship between field input and output devices in a control system and their power supply.
Field devices connected to the positive side (+V) of the field
power supply are sourcing field devices.
Field devices connected to the negative side (DC Common) of the
field power supply are called sinking field devices.
To maintain electrical compatibility between field devices and the programmable controller system, this definition is extended to the input/output circuits on the discrete I/O modules.
Sourcing I/O circuits supply (source) current to sinking field
devices.
Sinking I/O circuits receive (sink) current from sourcing field
devices.
Europe: DC sinking input and sourcing output module circuits are the commonly used options.
Publication
1747-6.2
Chapter 10
Troubleshooting
In this chapter, you will learn about:
calling Allen-Bradley for assistance
tips for troubleshooting your control system
troubleshooting the SLC 5/01 and SLC 5/02 processors
troubleshooting the SLC 5/03, SLC 5/04, and SLC 5/05
processors
troubleshooting your input modules
troubleshooting your output modules
Calling Allen-Bradley for Assistance
If you need to contact Allen-Bradley or local distributor for assistance, it is helpful to obtain the following (prior to calling):
processor type, series letter, operating system (OS) number
(obtained from the status file), firmware (FRN) number (see label on side of processor module)
processor LED status
processor error codes (found in S:6 of status file)
hardware types in system (I/O modules, chassis)
revision of programming device (on the main menu of the
Hand-Held Terminal or programming software)
Publication
1747-6.2
Loading...