Allegro A8284SLB, A8284SB Datasheet

8284
Data Sheet
27448.1
ADVANCE INFORMATION
(Subject to change without notice)
December 22, 2000
A8284SLB
OSEL
OLF
VBULK
LNBB
NC
GND
GND
SENSE
LNBA
LX
VIN
TCAP
1
2
3
4
5
6
7
8
9
9
10
BUCK
11
12
REG.
24
23
22
21
PUMP
CHARGE
20
19
18
17
16
15
14
VOLTAGE
CONTROL
13
EXTM
VINT
PUMPX
VPUMP
CPUMP
GND
GND
ENT
EN
VSEL0
VSEL1
LLC
TWO-OUTPUT LNB SUPPLY AND
CONTROL-VOLTAGE REGULATOR
Intended for analog and digital satellite receivers, the low noise block converter regulator (LNBR) is a monolithic linear and switching voltage regulator designed to provide power and interface signals to the LNB downconverter via the coaxial cable. Because most satellite receivers have two antenna ports, the output voltage of the regulator is available at one of two logic-selectable output terminals (LNBA, LNBB). If the device is in stand-by mode (EN terminal LOW), both regulator outputs are disabled, allowing the antenna downconverters to be supplied and controlled by other satellite receivers sharing the same coaxial cable. Similar single-output devices, with a bypass function for slave operation in single-dish dual-receiver systems, are the A8283SB/SLB.
The regulator outputs are set to 12, 13, 18, or 20 V by the VSEL terminals. Additionally, it is possible to increase the selected voltage by 1 V to compen­sate for the voltage drop in the coaxial cable (LLC terminal HIGH).
The LNBR combines a tracking switching regulator and low-noise linear regulators. Logic inputs (VSEL0, VSEL1, and LLC) select the desired output voltage. A tracking current-mode buck converter provides the linear regulator input voltage that is set to the output voltage plus typically 0.8 V. This maintains constant voltage drop across the linear regulators while permitting adequate voltage range for tone injection.
The device is supplied in a 24-pin plastic DIP with batwing tabs (A8284SB), or a 24-lead SOIC power-tab package (A8284SLB). In both cases, the power tab is at ground potential and needs no electrical isolation.
Dwg. PP-072-1A
Note that the A8284SB (dual in-line package) and A8284SLB (small-outline IC package) are electrically identical and share a common terminal number assignment.
ABSOLUTE MAXIMUM RATINGS
Supply Voltage, VIN.......................... 47 V
Output Current, IO.... Internally Limited
Logic Input Voltage Range,
VI................................... -0.5 V to +7 V
Flag Output Voltage, V
Operating Temperature Range,
TA............................... -20°C to +85°C
Storage Temperature Range,
TS............................. -40°C to +150°C
CONTACT FACTORY
.................. 7 V
OLF
FEATURES
Complete Interface for Two LNBs Remote Supply and Control
LNB Selection and Stand-By Function
Built-In Tone Oscillator Factory Trimmed to 22 kHz, Facilitates
DiSEqC™ (a trademark of EUTELSAT) Encoding
Full Modulation With No Load
Tracking Switch-Mode Power Converter for Lowest Dissipation
Externally Adjustable Short-Circuit Protection
LNB Short-Circuit Protection and Diagnostics
Auxiliary Modulation Input
Cable Length Compensation
Internal Over-Temperature Protection
This device incorporates features that have patents pending.
Always order by complete part number, e.g., A8284SLB .
8284
TWO-OUTPUT LNB SUPPLY AND CONTROL-VOLTAGE REGULATOR
FUNCTIONAL BLOCK DIAGRAM
VINT
ENT
OLF
VBULK
150 mV
RS
SENSE
LNBB
1
0
EXTM
LNBA
OSEL
Dwg. FP-051
47 V MAX
VPUMP
CHARGE
TSD
CPUMP
PUMP
176 kHz
OVER-CURRENT
PUMPX
VOLTAGE
REG.
EN
5 V
VIN
BOOST VOLTAGE
+
÷2
÷8
&
WAVESHAPING
7 V
352 kHz
BUCK
CONV.
22 kHz TONE
VREF
VSEL0
VSEL1
LX
OVER-
CURRENT
+
800 mV
TCAP
+
25 k
LLC
+
1 k
+
+
5 k
5 k
OSEL VSEL0 VSEL1 LLC V
LNBA(typ)VLNBB(typ)
LLLL13 VLow L L L H 14 V Low
L L H L 18 V Low L L H H 19 V Low L H L L 12 V Low L H L H 13 V Low L H H L 20 V Low
LHHH21 VLow HLLLLow13 V H L L H Low 14 V H L H L Low 18 V H L H H Low 19 V H H L L Low 12 V H H L H Low 13 V H H H L Low 20 V HHHHLow21 V
2
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 Copyright © 2000, Allegro MicroSystems, Inc.
Output Voltage Select Table
8284
TWO-OUTPUT LNB SUPPLY AND
CONTROL-VOLTAGE REGULATOR
ELECTRICAL CHARACTERISTICS at TA = 25°C, OSEL = H for LNBB, OSEL = L for LNBA (each output tested separately), ENT = L, EN = H, LLC = L, V noted).
Characteristic Symbol Test Conditions Min. Typ. Max. Units
= 24 V, IO = 50 mA (unless otherwise
IN
Limits
Supply Voltage V
Output Voltage V
Line Regulation ∆V
Load Regulation ∆V
Current-Limiting Threshold V
Tone Frequency f
Tone Amplitude V
OM(th)
tone
tone(PP)
Tone Duty Cycle dc
Tone Rise or Fall Time tr, t
External Modulation Gain G
External Modulation V
mod
mod(PP)
Input Voltage
IN
O
O
O
tone
IO = 600 mA, VSEL0 = L, VSEL1 = L, LLC = L
IO = 600 mA, VSEL0 = L, VSEL1 = L, LLC = L
IO = 600 mA, VSEL0 = L, VSEL1 = L, LLC = H
IO = 600 mA, VSEL0 = L, VSEL1 = H, LLC = L
IO = 600 mA, VSEL0 = L, VSEL1 = H, LLC = H
IO = 600 mA, VSEL0 = H, VSEL1 = L, LLC = L
IO = 600 mA, VSEL0 = H, VSEL1 = L, LLC = H
IO = 600 mA, VSEL0 = H, VSEL1 = H, LLC = L
IO = 600 mA, VSEL0 = H, VSEL1 = H, LLC = H
3.3 + ∆V
BUCK
47 V
12.5 13 13.5 V
13.4 14 14.6 V
17.3 18 18.7 V
18.2 19 19.8 V
11.5 12 12.5 V
12.5 13 13.5 V
19.2 20 20.8 V
20.2 21 21.8 V
VO = 13 V, VI = 16 to 40 V 4.0 40 mV
VO = 18 V, VI = 21 to 40 V 4.0 40 mV
VO = 13 or 18 V, IO = 50 to 600 mA 80 180 mV
125 135 145 mV
ENT = H 20 22 24 kHz
ENT = H 550 680 800 mV
ENT = H 40 50 60 %
f
ENT = H 5.0 10 15 µs
VO/V
, f = 10 Hz to 40 kHz 5.0 V/V
mod
AC coupling 160 mV
External Modulation Z Impedance
www.allegromicro.com
mod
f = 10 Hz to 40 kHz 5.0 k