ALLEGRO 2525, 2535 DATA SHEET

查询2535供应商
A2525EM
1
EN
GND
Note that the A2525EM (DIP) and the A2525EL (SOIC) are electrically identical and share a common terminal number assignment.
2
3
45
NC
GATE
CONTROL
NC
NC NC
OUT
8
IN
7
NC
6
NC
Dwg. PP-070A
ADVANCE INFORMATION
(subject to change without notice)
August 2, 1999
ABSOLUTE MAXIMUM RATINGS
Supply Voltage, V Output Voltage, V Output Current,
I
................. Internally Limited
OUT
ENABLE Voltage Range,
......................... –0.3 V to 10 V
V
EN
Fault Flag Voltage, V Fault Flag Current, I
Package Power Dissipation,
................................. See Graph
P
D
Operating Temperature Range,
......................... -40°C to +85°C
T
A
Junction Temperature, T Storage Temperature Range,
T
........................... -65°C to 150°C
S
* Fault conditions that produce excessive junction temperature will activate device thermal shutdown circuitry. These conditions can be tolerated but should be avoided.
..................... 6.0 V
IN
................... 6.0 V
OUT
.............. 8.0 V
FLG
............. 50 mA
FLG
....... +150°C*
J
2525
AND
2535
USB POWER CONTROL SWITCHES
The A2525EL/M and A2535EL/M are integrated high-side power switches, optimized for self-powered and bus-powered Universal Serial Bus (USB) applications. Few external components are necessary to satisfy USB requirements. The A2525EL/EM ENABLE inputs are active high; the A2535EL/EM are active low.
All devices are ideally suited for USB applications. Each switch channel supplies up to 500 mA as required by USB peripheral devices. In addition, the switch’s low on-resistance permits achieving the USB voltage-drop requirements. Fault current is limited to typically 750 mA, satisfying the UL 25 VA safety requirements, and a flag output is available to indicate a fault condition to the local USB controller. Momentary voltage drops that may occur on the upstream port when the switch is enabled in bus-powered applications is elimi­nated by a “soft start” feature.
Additional features include thermal shutdown to prevent catastrophic switch failure from high-current loads, undervoltage lockout to ensure that the device remains OFF unless there is a valid input voltage present, and 3.3 V and 5 V logic-compatible enable inputs.
These switches are provided in 8-pin mini-DIP (suffix ‘M’) and 8-lead SOIC (suffix ‘L’) packages.
Features
2.7 V to 5.8 V Input
Up to 500 mA Continuous Load Current
140 m Maximum ON-Resistance
1.25 A Maximum Short-Circuit Current Limit
Individual Open-Drain Fault Flag Outputs
110 µA Typical ON-State Supply Current
1 µA Typical OFF-State Supply Current
Outputs Can be Forced Higher Than Input (off-state)
Thermal Shutdown
2.4 V Typical Undervoltage Lockout
1 ms Turn On (soft-start) and Fast Turn Off
Active-High or Active-Low Enable Versions
Improved Replacements for MIC2525-1 and MIC2525-2
Applications
USB Hosts and Self-Powered Hubs
USB Bus-Powered Hubs
Hot Plug-In Power Supplies
Battery-Charger Circuits
Data Sheet
27447.1
2525
AND
2535
USB POWER CONTROL SWITCHES
A2535 ONLY
EN
CHARGE
PUMP
FUNCTIONAL BLOCK DIAGRAM
GATE
CONTROL
FLG
OUT
CURRENT
LIMIT
EN
FLG
GND
OSC
1.2 V REF.
TSD
UVLO
IN
GND
Dwg. FP-049
2.5
A2535EM
2.0
1
2
3
GATE
CONTROL
NC
OUT
8
IN
7
NC
6
1.5
1.0
SUFFIX 'M', R
θJA
= 60°C/W
45
NC
NC NC
NC
Dwg. PP-070-1A
Note that the A2535EM (DIP) and the A2535EL (SOIC) are electrically identical and share a common terminal number assignment.
0.5
0
ALLOWABLE PACKAGE POWER DISSIPATION IN WATTS
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 Copyright © 1999, Allegro MicroSystems, Inc.
SUFFIX 'L', R
25
50 75 100 125 150
AMBIENT TEMPERATURE IN °C
θJA
= 108°C/W
Dwg. GP-009-2
2525
AND
2535
USB
POWER CONTROL
SWITCHES
Electrical Characteristics at T
= 25°C, V
A
= 5 V (unless otherwise noted).
IN
Limits
Parameter Test Conditions Min Typ Max Units
Operating Voltage Range V
IN
Switch Resistance VIN = 5 V, I
= 500 mA 100 140 m
OUT
2.7 5.8 V
VIN = 3.3 V, IOUT = 500 mA 100 140 m
Output Leakage Current Output disabled, VIN = 5 V, V
= 0 10 µA
OUT
Maximum Load Current 500 mA
Short-Circuit Current Limit Output enabled into load, V
Current-Limit Threshold Ramped load applied to enabled output, V
= 4 V 0.5 1.25 A
OUT
4 V 1.6 A
OUT
ENABLE Input Threshold Low-to-high transition 2.1 2.4 V
High-to-low transition 0.8 1.9 V
ENABLE Input Hysteresis 0.2 V
ENABLE Input Current V
= 0 V to 5.5 V ±0.01 ±1.0 µA
EN
ENABLE Input Cap. 1.0 pF
Output Turn-On Delay R
Output Turn-On Rise Time R
Output Turn-Off Delay R
Output Turn-Off Fall Time R
Error Flag Output VIN = 5 V, I Resistance
Error Flag Off Current V
= 10, each output 0.5 ms
L
= 10 each output 1.0 ms
L
= 10 each output 1.0 µs
L
= 10 each output 1.0 µs
L
= 10 mA 10
L
VIN = 3.3 V, I
= 5 V 0.01 µA
FLG
= 10 mA 15
L
Supply Current Switch OFF (see note), OUT = open 0.75 5.0 µA
Switch ON (see note), OUT = open 110 160 µA
UVLO Threshold Increasing V
Decreasing V
Over-Temperature Increasing T Shutdown Threshold
Decreasing T
IN
IN
J
J
2.5 V
2.3 V
165 °C 155 °C
Note — OFF is 0.8 V and ON is 2.4 V (active high) for the A2525EL/EM. OFF is 2.4 V and ON is 0.8 V (active low) for the A2535EL/EM.