Allegion QELX, HD-QELX Installation Manual

Page 1
*24908386*
QEL 33A/35A,
24908386
Conversion Kit
1. This kit converts all 33/35A and 98/99 series mechanical exit devices to quiet electric latch (QEL) retraction devices.
2. QELX and HD-QELX Kits are only for use with Von Duprin AX98/99, AXXP98/99, and AX33A/35A exit devices.
3. This kit can also be used for motor replacement on existing QEL devices.
4. Install according to instructions or device will not function and panic or re label will be void.
5. The QEL wiring must be attached to the re alarm system if installed on re exit hardware.
6. If existing device is re rated or less dogging a QEL baseplate conversion kit is required.
HD-QEL Conversion Kit w/ Dogging (Panic Only) - 958002
QEL Conversion Kit - 114317
98/99 Series
3 Remove Exit Device from Door
110388
114320
116549
110388
114320
116549
a
c
Unplug cable,
Installation Instructions
Device and trim must be held
!
b
securely while screws are being removed, to prevent dropping to the floor
110388
114320
116549
QELX Conversion Kit - 041162
110388
114320
116549
HD-QELX Conversion Kit w/ Dogging (Panic Only) - 041164
WARNING
If existing exit device is re rated, do not install HD-QEL or HD-
QELX (hex dogging) type motor. Doing so will void re rating.
1 Disconnect Power
To avoid risk of shock, disconnect AC power from power supply before proceeding with this conversion. If using 900-BB Battery
Backup option, unplug all four wires from battery terminals.
d
4 Remove Mechanism Case
d
Keep all parts
b
33a/35a
c
b
a
OR
98/99
2 Detach Vertical Rods if present
Refer to device instructions as needed.
a
a
Page 2
5 Prepare baseplate for new motor. Find your existing application below (on page 2 or 3) and follow steps.
FIRE OR LESS DOGGING DEVICE (Applies to exit devices built after October 2014. Baseplate conversion kit required for earlier devices.)
1. Remove pushpad from baseplate.
Keep pushbar
2. Install connector and pin.
QEL DEVICE (built prior to December 2014)
1. Remove existing QEL motor
b
a
c
2. Discard old QEL motor assembly.
Verify pin is snapped in place on other side of action rod. Pin should be inserted from side that will be up when device is mounted on door.
b
a
2
Page 3
5 Continued
Rivet may tend to spin with drill bit.
QEL DEVICE (built after December 2014)
1. Remove existing QEL motor.
a
b
2. Discard old QEL motor assembly.
PANIC DEVICE (with dogging assembly)
1. Remove two screws from dogging assembly. If riveted see below.
2. Drill or use center punch on two rivet heads until rivets can be removed from baseplate.
1/4” or 5/16”
or
Note: Do not drill through baseplate.
3. Remove and discard dogging assembly.
3
Page 4
6 Install New QEL Motor Assembly
"
New QEL
motor assembly
8 Prepare dogging cover for HD dogging key (if
applicablle and only on panic devices).
8a Locate and drill hole
1/4”
7 Install Mechanism Case
a
Center of Cover
Deburr edge of hole
1 1/2”
8b Install dogging cover
b
9 Drill Wire Access Hole (if required)
⁵⁄₁₆
33/35
b
a
a
c
d
Drill ⁵⁄₈" dia. access hole through device side of door.
OR
98/99
b
4
Page 5
10 Attach Exit Device to Door
d
a
b
For more detailed installation instructions for specic Exit Devices, visit the Support area of the Allegion website at www.allegion.com/us
11 Conrm Equipment Compatibility
The QEL is compatible with the following equipment (refer to individual instructions as needed):
• PS900-SERIES Power Supplies - PS902, PS904, PS906, PS914
• 900-SERIES Option Boards - 900-2RS, 900-4R, 900-4RL, 900-2Q
• PS873 Power Supply Plus 871-2, 871-2Q, 873-4TD/AO Option Boards
12 Route Two Wires from QEL Exit Device to Power Supply
QEL Electrical Load
Voltage: 24 VDC Current: 1.0 A inrush (0.5 sec)
0.14 A holding
PS900-Series power supply with 900-Series option board(s) installed
QEL device used with
EPT, Door Loop, or
Electric Hinge/Pivot
Distance
(one way)
200’ 18AWG
320’ 16AWG
500’ 14AWG
800’ 12AWG
Wire
Gauge
EPT shown. A door loop or electric hinge/pivot may also be used.
QEL Exit
Device
Note: Power wires to QEL are not polarized.
5
Page 6
13 Install 900-2Rs, 4Rl, or 4R Option Board(s) into Power Supply
b
c
Secure Board(s) with Screws
Option 1
Option 2
Option 1
Option 3
Option 2
Option 1
PS902 1 Board
PS904, 914 2 Boards
PS906 3 Boards
1
a
Review Available 900 series Option Board Mounting Locations (Gray)
PS902
PS904
PS914
PS906
1
1 2
2
3
1
Plug Option Board Cable into any Available Option Connector
3. The QEL is compatible with an existing 900-2Q board if currently installed.
5. When powering multiple components, verify that the amperage requirements of all components combined does not exceed the power supply output rating.
4. Latchbolt retraction of (2) sequenced QEL’s requires more than 1 second to complete.
2. If installing board in location 2 or 3, rotate board 180˚
Notes: 1. 24VDC output setting required when QEL
device connected
14 Connect Input and Output Wires to Option Board (2RS Shown)
Sequential Mode - Typical Wiring
Note:
Fail secure output only allowed if approved by Authority Having Jurisdiction
PS900
Series
120/240 VAC
50/60Hz
SC I1 01 I2 02 GND
2RS
Access Control
for
Devices
1 & 2
(PS900
Series only)
Input I1 will activate both outputs
EPT-2/10
QEL Device 1 QEL Device 2
EPT-2/10
Individual Mode - Typical Wiring
PS900 Series
2RS
SC I1 01 I2 02 GND
120/240 VAC
50/60Hz
Access Control
Device 2
Access Control
Device 1
Input I1 will activate output 1 Input I2 will activate output 2
EPT-2/10
QEL Device 2
for
EPT-2/10
QEL Device 1
for
6
Page 7
15 Check Operation
A. Activate each input and verify all QEL devices operate properly.
B. If any device does not operate properly, see step 16 for troubleshooting.
16 If Necessary, Troubleshoot Operation (LED is only visible with the mechanism cover removed)
Power at the
QEL
LED - Solid green Latchbolt - retracted
LED - Solid red after latchbolt
24VDC
24VDC low
29VDC or
greater
13VDC or
lower
0VDC
0VDC
*For information about adjusting exit devices, you can nd their installation instructions in the support area at www.allegion.com/us
or call Technical Services at 1-877-671-7011
attempts to retract multiple times
LED - Flashing green/red Latchbolt - not retracted
LED - Flashing green Latchbolt - retracted
LED- Flashing red Latchbolt - will not retract
LED - o󰀨 Latchbolt - not retracted
LED - o󰀨 Latchbolt - retracted
QEL Response Condition/Solution
Operation normal, latch retracted immediately
Latchbolt cannot fully retract mechanically
Verify mechanical adjustment (on vertical rod or mortise lock devices if used). Remove and reapply input voltage to reset this condition.*
See Check Mechanical Operation on page 8 as needed.** Excessive tamper (while power applied, the pushpad was pulled out at least 3 time)
Wait 15 seconds and latchbolt will retract again OR remove and reapply power to clear condition Voltage low during latchbolt retraction (latchbolt retracts at reduced force) Wire length is too long, wire gauge is too small or power supply has poor regulation Input voltage is too high for proper operation
Wrong power supply, power supply defective. Input voltage is too low for proper operation
Wrong power supply, power supply defective or not set to the proper output voltage.
To set, remove AC power from power supply, change power supply setting from 12 to 24VDC, then reapply AC power and verify proper operation. No input voltage
Problem with the power supply, control switch or wiring No input voltage
Mechanical dogging is engaged
LED
on Device
7
Page 8
17 Check Mechanical Operation
33A/3527A 98/9927 98/9947WDC
33A/3547A 98/9947 98/9957
98/9975
1. Make sure device is not dogged for SD-QEL / HD-QEL.
2. Depress pushbar and make sure latch bolt retracts and extends fully (see Figure 1).
3. If latch bolt does not retract or extend fully, adjustments may be required per the device installation instructions.
33A/3527A, 98/9927, 98/9957
Latch bolt deadlocked (will not
Latch bolt stays retracted
Release trigger extended
push in)
with door
closed
³⁄₁₆"
with door
open
33A/3547A, 98/9947, 98/9947WDC
Latch bolt deadlocked (will not push in)
Flush within ¹⁄₁₆"
⁵⁄₈"
33/3549A 98/9949
33/3550A-WDC 98/9949WDC
98/9950WDC
1. Make sure device is not dogged for SD-QEL/HD-QEL.
2. Depress pushbar. Door should begin to open with pushbar depressed halfway.
3. Close door. Top latch should be secure. If two point latch, bottom latch should be secure as well.
4. If device does not function as described in steps 2 and 3, adjustments may be required per the device installation instructions.
Any HD Device
1. Fully depress pushbar.
2. Insert hex dogging key and turn clockwise.
3. Release pushbar and verify latchbolt remains retracted.
4. Fully depress pushbar.
5. Insert hex dogging key and turn counter clockwise.
6. Release pushbar and verify latchbolt extends fully.
Latch bolt
extended
98/9975
Latch bolt extended
³⁄₄"
Figure 1
Latch bolt
retracted
Latch bolt retracted Flush within ¹⁄₁₆"
Customer Service
1-877-671-7011 www.allegion.com/us
© Allegion 2020
Printed in U.S.A.
24908386 Rev. 10/20-d
Loading...