electrically unlocked (fail secure) with request-to-exit36 Institution lock37 Faculty restroom lock38 Entrance/oce and entrance lock with Vandlgard39 Vestibule lock with Vandlgard40 Classroom lock with Vandlgard41 Classroom security lock with Vandlgard42 Storeroom lock with Vandlgard43 Storeroom lock with Vandlgard44 Storeroom lock with Vandlgard®— electrically locked
(fail safe) or electrically unlocked (fail secure)45 Storeroom lock with Vandlgard®— electrically locked
(fail safe) or electrically unlocked (fail secure) with
request-to-exit46 Corridor lock with Vandlgard
®
®
®
®
®
®
with request-to-exit
®
®
®
47 Trim assemblies
48 Passage latch49 Passage latch with request-to-exit50 Exit lock51 Exit lock with request-to-exit52 Exit lock— electrically locked (fail safe) or electrically
unlocked (fail secure)
53 Exit lock— electrically locked (fail safe) or electrically
unlocked (fail secure) with request-to-exit54 Single dummy trim55 Double dummy trim56 Exit lock with blank plate57 Special— classroom exit lock58 Special— storeroom exit lock59 Special— patio lock60 Bath/bedroom privacy lock61 Hospital privacy lock62 Time out lock with Vandlgard
®
63 Entrance/oce lock64 Entrance/oce lock65 Vestibule lock66 Special— ND60 with closed outside lever67 Store lock68 Classroom lock69 Special— classroom by storeroom lock70 Special— communicating lock71 Special— communicating lock with Vandlgard
®
72 Corridor lock73 Classroom security lock74 Storeroom lock75 Storeroom lock with request-to-exit76 Storeroom lock— electrically locked (fail safe) or
electrically unlocked(fail secure) with request-to-exit78 Institution lock79 Faculty restroom lock80 Entrance/oce lock with Vandlgard81 Entrance lock with Vandlgard82 Vestibule with Vandlgard
®
83 Classroom lock with Vandlgard84 Classroom security lock with Vandlgard85 Storeroom lock with Vandlgard
®
®
®
®
®
86 Storeroom lock with Vandlgard® with request-to-exit87 Storeroom lock with Vandlgard®— electrically locked
(fail safe) or electrically unlocked (fail secure)88 Storeroom lock with Vandlgard®— electrically locked
(fail safe) or electrically unlocked (fail secure) with
request-to-exit89 Corridor lock with Vandlgard
®
90 Conversion
90 Spring cage conversion91 Lever conversion91 Button and plunger assembly conversion92 Lever conversion kits
93 Levers
93 Tactile warning levers
95 Roses
96 IC cylinder configurations
97 Cylinders
98 Competitor cylinder options
99 Latches
99 Strikes
100 Parts
100 Screws, screw packs, and special parts
102 Installation tools and kits
104 Electrified locks
104 Allegion Connect
105 Request-to-exit feature
106 High security ligature resistant
(HSLR) trim
107 Finishes
108 Ordering procedures
109 Limited warranty
iv • Schlage • ND-Series service manual
Introduction
Turn/push button
This manual contains a complete listing of ND-Series (Grade 1) cylindrical lock parts and assemblies manufactured by the
Schlage Lock Company. This edition lists components of ND-Series locks manufactured aer February, 2017.
This manual provides exploded views of each lock chassis and trim assembly with an accompanying chart to identify parts for
replacement purposes, along with lock trim ordering procedures, general cylinder information, and all auxiliary components of
the ND-Series cylindrical locks.
Standard Features*
Exceeds BHMA A156.2 requirements for Grade 1 cylindrical locks.
Certifications
Latch
Strike
Backset
Cylinder6-Pin solid brass, keyed 6-pin, S123 keyway, keyed different (KD)**
Door Range
KeysTwo nickel silver cut keys per lock, 6-pin, S123 section**
* Locks are furnished with standard features unless otherwise specified.
** Items specified in C keyway will be furnished with cylinder keyed 5-pin and with 5-pin keys unless otherwise specified.
Exceeds BHMA A156.25 requirements for indoor electrified locks.
UL10C listed for 3-hour fire doors up to 4'0" x 10'0"
Meets Florida Building Code (ASTM E330, E1886, E1996) and Miami-Dade (TAS 201, 202, 203) requirements for hurricanes.
ND10F75Passage latchLever is always unlocked.Lever is always unlocked
ND12F89Exit lockLever is always fixed.Lever is always unlocked
ND12ELExit lock —
electrically locked
(fail safe)
ND12EUExit lock—
electrically
unlocked (fail
secure)
ND170Single dummy trim Inactive trim for one side
Lever is continuously
locked electrically until
unlocked by switch or
power failure.
Auxiliary latch deadlocks
latch bolt when door is
closed.
Lever is continuously
locked mechanically until
unlocked by electric
current.
Auxiliary latch deadlocks
latch bolt when door is
closed.
of door.
For use as door pull or
matching inactive trim.
and is always free for
immediate egress.
With available
request-to-exit (RX)
feature.
and is always free for
immediate egress.
With available
request-to-exit (RX)
feature.
Lever is always unlocked
and is always free for
immediate egress.
With available
request-to-exit (RX)
feature.
Lever is always unlocked
and is always free for
immediate egress.
With available
request-to-exit (RX)
feature.
48
49
50
51
52
53
52
53
54–
12
13
14
15
16
17
16
17
ND172Double dummy
trim
ND25F89Exit lock with blank
plate
ND25 x 70Classroom exit
lock
Specify per
XN12-004
Note: Any function with a dead latch locks the latch bolt when door is closed. See page 5 for identification.
Caution: Double cylinder locks on residences and any door in any structure which is used for egress are a life safety hazard in times of emergency and
their use is not recommended. Installation should be in accordance with existing codes only.
Inactive trim for both sides
of door.
No latch. (Blank latch
cover available.)
No cylinder.
For use as door pull or
matching inactive trim.
Blank plate.Inside lever is always
Blank plate.Key locks or unlocks lever.5719
Inactive trim for both sides
of door.
For use as door pull or
matching inactive trim.
unlocked and is always free
for immediate egress.
55–
5618
6 • Schlage • ND-Series service manual
Lock assembly drawing index
FunctionANSI/BHMA A156.2, 2011, Series 4000, Grade 1TrimChassis
Note: Any function with a dead latch locks the latch bolt when door is closed. See page 5 for identification.
Caution: Double cylinder locks on residences and any door in any structure which is used for egress are a life safety hazard in times of emergency and
their use is not recommended. Installation should be in accordance with existing codes only.
May be opened from
outside with small
screwdriver or emergency
release tool.
Unlocked from outside by
turning emergency
turn-button.
(detention side) is locked
by pushing and holding
button. Inside lever is
locked until button is
released. Lever always
retracts latch.
Lever is unlocked with key
or by turning inside lever,
when push-button is
pushed and locked on
inside.
retracts latch when button
is pushed and turned until
button is manually
unlocked.
Push-button: Lever is
unlocked with key when
push-button is pushed.
when locked by key in
inside lever.
Push-button locks outside
lever. Turning inside lever or
closing door releases
push-button preventing
lock-out.
Lever is always unlocked
and is always free for
immediate egress.
Push-button locks outside
lever. Turning inside lever or
closing door releases
push-button.
Inside lever is always free
for immediate egress.
Push-button locks outside
lever. Turning inside lever or
closing door releases
push-button.
Inside lever is always free
for immediate egress.
Detention side: Lever
retracts latch unless outside
(caretaker side) button is
depressed.
Vandlgard allows inside
spindle to disengage from
latch when locked.
Push-button locks outside
lever. Turning inside lever
releases push-button.
Inside lever is always free
for immediate egress.
Push/turn-button: Pushing
and turning button locks
outside lever until manually
unlocked.
Push-button: Pushing
button locks outside lever
until unlocked by key
outside or by turning inside
lever.
Inside always free for
immediate egress.
Inside key locks and unlocks
outside lever.
Inside lever is always
unlocked and is always free
for immediate egress.
5921
6021
6121
6222
6323
6423
6524
Schlage • ND-Series service manual • 7
Lock assembly drawing index
FunctionANSI/BHMA A156.2, 2011, Series 4000, Grade 1TrimChassis
Outside lever only locked
or unlocked by outside key.
Inside lever only locked or
unlocked by inside key.
7028
Specify per
XN12-002
ND72 Vandlgard
ND73F90Corridor lockLocked or unlocked by
®
Communicating
lock with
Vandlgard
Specify per
XN12-003
Same as ND72.
Vandlgard allows outside
spindle to disengage from
latch when locked. Both
levers are clutching.
outside key. When locked
by key it can only be
unlocked by key. Pushbutton locks from inside.
Same as ND72.
Vandlgard allows inside
spindle to disengage from
latch when locked. Both
levers are clutching.
Push-button locks outside
lever. Turning lever or
closing door releases
button. Inside lever is
always unlocked and is
7129
7230
always free for immediate
egress.
ND75F110Classroom security
lock
Outside lever locked or
unlocked by key in either
lever.
Key locks or unlocks outside
lever.
Inside lever is always
7331
unlocked and is always free
for immediate egress.
ND80F86Storeroom lockLever is fixed. Entrance by
key only.
Inside lever is always
unlocked and is always free
74
32
for immediate egress.
With available
75
33
request-to-exit (RX)
feature.
Note: Any function with a dead latch locks the latch bolt when door is closed. See page 5 for identification.
Caution: Double cylinder locks on residences and any door in any structure which is used for egress are a life safety hazard in times of emergency and
their use is not recommended. Installation should be in accordance with existing codes only.
8 • Schlage • ND-Series service manual
Lock assembly drawing index
FunctionANSI/BHMA A156.2, 2011, Series 4000, Grade 1TrimChassis
Unlocked by key outside or
by switch or power failure.
When locked, key retracts
latch.
Auxiliary latch deadlocks
latch bolt when door is
closed.
Lever is continuously
locked until unlocked by
key outside or by electric
current. When locked, key
retracts latch.
Auxiliary latch deadlocks
latch bolt when door is
closed.
Lever is fixed. Entrance by
key only.
Inside lever is always
unlocked and is always free
for immediate egress.
With available
request-to-exit (RX)
feature.
Inside lever is always
unlocked and is always free
for immediate egress.
With available request-toexit (RX) feature.
Lever is fixed. Exit by key
only.
76
77
76
77
7836
34
35
34
35
ND85Faculty restroom
lock
ND91F82Entrance/oce
lock with
Vandlgard
ND92F109Entrance lock with
Vandlgard
Note: Any function with a dead latch locks the latch bolt when door is closed. See page 5 for identification.
Caution: Double cylinder locks on residences and any door in any structure which is used for egress are a life safety hazard in times of emergency and
their use is not recommended. Installation should be in accordance with existing codes only.
Lever is fixed. Entrance by
key only.
Lever is unlocked with key
when push-button is
pushed.
Vandlgard allows outside
spindle to disengage from
latch when locked.
When turn/push-button is
pushed and turned, key
retracts latch. When
push-button is pushed,
lever is unlocked with key.
Vandlgard allows outside
spindle to disengage from
latch when locked.
Push-button activates
occupancy indicator,
allowing only emergency
master key to operate.
Turning lever or closing door
releases occupancy
indicator. Rotation of button
by spanner key provides
lock-out feature by keeping
indicator thrown.
Inside lever is always free
for immediate egress.
Push-button disengages
outside lever. Turning inside
lever or outside key releases
push-button.
Inside lever is always free
for immediate egress.
Turn/push-button: Pushing
and turning button
disengages outside lever
until manually unlocked.
Push-button: Pushing
button disengages outside
lever until unlocked by
turning inside lever or by
key outside.
Inside always free for
immediate egress.
7937
8038
8138
Schlage • ND-Series service manual • 9
Lock assembly drawing index
FunctionANSI/BHMA A156.2, 2011, Series 4000, Grade 1TrimChassis
with Vandlgard —
electrically
unlocked (Fail
secure)
ND97Corridor lock with
Vandlgard
Note: Any function with a dead latch locks the latch bolt when door is closed. See page 5 for identification.
Caution: Double cylinder locks on residences and any door in any structure which is used for egress are a life safety hazard in times of emergency and
their use is not recommended. Installation should be in accordance with existing codes only.
Latch retracted by key
when locked by inside key.
Key locks and unlocks
lever.
Vandlgard allows outside
spindle to disengage from
latch when locked.
Outside lever disengaged
or unlocked by key.
Vandlgard allows outside
spindle to disengage from
latch when locked.
Outside lever locked or
unlocked by key in either
lever.
Vandlgard allows outside
spindle to disengage from
latch when locked.
Lever always disengaged.
Entrance by key only.
Vandlgard allows outside
spindle to disengage from
latch when locked.
Lever is continuously
disengaged electrically.
Unlocked by key or by
power failure or switch.
Auxiliary latch deadlocks
latch bolt when door is
closed.
Vandlgard allows outside
spindle to disengage from
latch when locked.
Lever is continuously
disengaged until unlocked
by key or electric current.
Auxiliary latch deadlocks
latch bolt when door is
closed.
Vandlgard allows outside
spindle to disengage from
latch when locked.
Locked or unlocked by key.
When locked by key,
outside lever can only be
unlocked by key.
Vandlgard allows outside
spindle to disengage from
latch when locked.
Outside lever is disengaged
by key inside.
Inside lever is always
unlocked and is always free
for immediate egress.
Inside lever is always
unlocked and is always free
for immediate egress.
Outside lever locked or
unlocked by key in either
lever.
Inside lever is always
unlocked and is always free
for immediate egress.
Inside lever is always
unlocked and is always free
for immediate egress.
With available request-toexit (RX) feature.
Inside is always free for
immediate egress.
With available request-toexit (RX) feature.
Inside is always free for
immediate egress.
With available request-toexit (RX) feature.
Push-button locking.
Turning inside lever or
closing door releases
button.
Inside is always unlocked
and free for immediate
egress.
8239
8340
8441
85
86
87
88
87
88
8946
42
43
44
45
44
45
10 • Schlage • ND-Series service manual
Chassis
12 Passage latch13 Passage latch with request-to-exit14 Exit lock15 Exit lock with request-to-exit16 Exit lock— electrically locked (fail safe) or electrically unlocked (fail secure)17 Exit lock— electrically locked (fail safe) or electrically unlocked (fail secure) with request-to-exit18 Exit lock with blank plate19 Special— classroom exit lock20 Special— storeroom exit lock21 Patio, bath/bedroom privacy and hospital privacy lock22 Time out lock with Vandlgard23 Entrance/oce and entrance lock24 Vestibule lock25 Store lock26 Classroom lock27 Special— classroom by storeroom lock28 Special— communicating lock29 Special— communicating lock with Vandlgard30 Corridor lock31 Classroom security lock32 Storeroom lock33 Storeroom lock with request-to-exit34 Storeroom lock— electrically locked (fail safe) or electrically locked (fail safe)35 Storeroom lock— electrically locked (fail safe) or electrically unlocked (fail secure) with request-to-exit36 Institution lock37 Faculty restroom lock38 Entrance/oce and entrance lock with Vandlgard39 Vestibule lock with Vandlgard40 Classroom lock with Vandlgard41 Classroom security lock with Vandlgard42 Storeroom lock with Vandlgard43 Storeroom lock with Vandlgard44 Storeroom lock with Vandlgard®— electrically locked (fail safe) or electrically unlocked (fail secure)45 Storeroom lock with Vandlgard®— electrically locked (fail safe) or electrically unlocked (fail secure) with request-to-exit46 Corridor lock with Vandlgard
®
®
®
®
®
®
with request-to-exit
®
®
®
Chassis
Passage latch
ND10
37
52
23
30
38
a
a
Apply light film of 100% synthetic grease on surfaces with brush.
No.DescriptionPart number
1Slide springC503-019
6Chassis screwL583-454
23Outside housing24088544
24Inside hub24085037
29SlideN523-149
1
53
a
a
29
38
24
No.DescriptionPart number
30Slide clipN523-025
37Adjustment plateN523-054
38SpindleN523-177
52Gauge insert23988066
53Insert, inside hubN523-160*
a
6
* Not sold separately as a part.
12 • Schlage • ND-Series service manual
Chassis
Passage latch with request-to-exit
ND10 RX
37
52
23
30
38
a
29
a
Apply light film of 100% synthetic grease on surfaces with brush.
No.DescriptionPart number
1Slide springC503-019
6Chassis screwL583-454
23Outside housing24088544
27Inside hub, electrified and RX24085078
29SlideN523-149
30Slide clipN523-025
1
53
a
a
49
38
a
27
No.DescriptionPart number
37Adjustment plateN523-054
38SpindleN523-177
48RX harnessN523-194**
49RX harness screwN523-135
52Gauge insert23988066
53Insert, inside hubN523-160*
6
48
* Not sold separately as a part.
** For RX details, see Request-to-exit feature on page 105.
Schlage • ND-Series service manual • 13
Chassis
Exit lock
ND12
37
52
23
22
a
a
Apply light film of 100% synthetic grease on surfaces with brush.
No.DescriptionPart number
1Slide springC503-019
6Chassis screwL583-454
8Keycam assemblyN123-008
22SpindleN523-013
23Outside housing24088544
24Inside hub24085037
30
8
1
53
a
a
a
29
a
38
24
No.DescriptionPart number
29SlideN523-149
30Slide clipN523-025
37Adjustment plateN523-054
38SpindleN523-177
52Gauge insert23988066
53Insert, inside hubN523-160*
6
* Not sold separately as a part.
14 • Schlage • ND-Series service manual
Chassis
Exit lock with request-to-exit
ND12 RX
37
52
23
22
8
a
a
a
Apply light film of 100% synthetic grease on surfaces with brush.
No.DescriptionPart number
1Slide springC503-019
6Chassis screwL583-454
8Keycam assemblyN123-008
22SpindleN523-013
23Outside housing24088544
27Inside hub, electrified and RX24085078
29SlideN523-149
29
30
1
53
a
a
49
51
a
27
No.DescriptionPart number
30Slide clipN523-025
37Adjustment plateN523-054
48RX harnessN523-194**
49RX harness screwN523-135
51RX inside spindleN523-177
52Gauge insert23988066
53Insert, inside hubN523-160*
6
48
* Not sold separately as a part.
** For RX details, see Request-to-exit feature on page 105.