Allegion 5547EO, 5547DT, 5547L, 5547NL, 5547TL Installation Instructions

*911066-00*
911066-00
Concealed Vertical Rod Exit Device for Metal Doors
5547EO, 5547DT,
5547L, 5547NL,
1 Check handing of device. Reverse if necessary.
Installation Instructions
& 5547TL
b b
REVERSING PROCEDURE FOR LOCK STILE CASE
Invert the case and reassemble in order shown (a thru d) with opposite hand lever arm from hinge case.
REVERSING PROCEDURE FOR HINGE STILE CASE
Disassemble hinge stile case, rotate parts as shown with spring always at the bottom. Reassemble in order shown (a thru d) with opposite hand lever arm from center case.
LH lever
arm
LHR
RHR
a a
Lock Stile Case
LHR
Bushing
RHR
aa
RH lever
arm
dd
cc
RH lever
arm
When exchanging parts, be certain that one bushing remains on the hub of each case.
Hinge Stile Case
bb
LH lever arm
2 Prepare door.
This device is for metal door only.
a. Tape door template (page 4) to inside face of lock stile according to handing. Be sure vertical centerline of device on template
is parallel to edge of door and backset is as shown in schedule below. Be sure horizontal centerline of device is 39-13/16” from
nished oor.
b. Prepare door as shown. c. Prepare door for top and bottom bolt guides. See Figures 1 and 2 below. d. If door requires trim, make additional preparations per trim template.
¹⁄₄"
⁷⁄₃₂" R
"A" or "B" - See
page 4 template
for correct hole
See
backset
schedule
preparation
³⁄₁₆" Min. to
edge of stop
¹⁄₄"
⁷⁄₃₂"
1³⁄₄" Min. stile width
X
Device & Latch Bolt
C
L
¹⁄₄"
3"
7¹⁄₄"
C
L
Device
DEVICE INSTALLATION SCHEDULE
Installation
Flush hollow metal door
Minimum 1-3/4" to 2-1/2" door stile
Stiles wider than 2-1/2"
Stop height of 1/2" minimum required.
FIG. 1 (TOP PREP)
Device & Latch Bolt
C
L
#12-24 Tap 3 holes
2¹⁄₄"
1³⁄₄"
⁵⁄₈"
1¹⁄₄" Typ.
2⁷⁄₃₂"
³⁄₄"
Backset
from high side
of bevel
2-1/2"
Single Door 1-9/32"
Double Door 1-5/32"
1/2 of stile
¹⁹⁄₆₄"
¹⁹⁄₃₂"
¹⁄₂"
1¹⁄₈"
⁷⁄₈"
C
L
Latch Bolt
2
"A" or "B" - See
page 4 template
for correct hole
preparation
39¹³⁄₁₆" to finished floor
¹⁄₄" max undercut
¹⁵⁄₃₂"
1³⁄₁₆"
or threshold
needed
5¹⁄₂"
¹⁵⁄₁₆"
of trim if required
C
L
X
3"
⁷⁄₃₂"
METAL DOOR APPLICATION
Inside face of lock stile
LHR shown, RHR opposite
FIG. 2 (BOTTOM PREP)
Device & Latch Bolt
C
L
⁵⁄₈"
1³⁄₄"
2¹⁄₄"
¹⁵⁄₁₆" Dia.
2⁷⁄₃₂"
#12-24 Tap 3 holes
³⁄₄"
¹⁄₂"
¹⁹⁄₆₄"
¹⁹⁄₃₂"
⁷⁄₈"
1¹⁄₈"
C
L
Latch Bolt
THIS PAGE
INTENTIONALLY
BLANK
3
DEVICE INSTALLATION SCHEDULE
Installation
Flush hollow metal door
Minimum 1-3/4" to 2-1/2" door stile
Stiles wider than 2-1/2"
Backset
from high side
of bevel
2-1/2"
Single Door 1-9/32"
Double Door 1-5/32"
1/2 of stile
DEVICE
BACKSET
(SEE SCHEDULE)
C
L
BACKSET
(SEE SCHEDULE)
Actual Size
1"
Do Not Scale
Stop height of 1/2" minimum required.
SCREW CHART
Check door material and metal thickness
For correct hole preparation
A B
Aluminum Doors
Unreinforced Hollow Metal Doors
7/32" Dia.
2 holes for sex bolt head
DEVICE
C
L
Reinforced
Hollow Metal Doors
1/4-28 Tap
2 holes for hex stud
XX
RHRLHR
EDGE OF STOP
(Single door application only)
3/16" MIN.MIN. 3/16"
TO FINISHED
4
39¹³⁄₁₆"
FLOOR
EDGE OF
STOP
(Single door
application
only)
IF REQUIRED
OF TRIM
LHR DOOR
C
L
XX
OF TRIM IF REQUIRED
C
L
RHR DOOR
Loading...
+ 8 hidden pages