Algo 2506 Installation Manual

Document 90-00082J Algo Communication Products Ltd (604) 454-3792 2019-10-30 4500 Beedie St Burnaby BC Canada V5J 5L2 support@algosolutions.com Page 1 www.algosolutions.com
2506 Polycom Ring Detector
Order Codes
2506 Polycom Ring Detector
Document 90-00082J Algo Communication Products Ltd (604) 454-3792 2019-10-30 4500 Beedie St Burnaby BC Canada V5J 5L2 support@algosolutions.com Page 2 www.algosolutions.com
Table of Contents
ABOUT THE ALGO 2506 POLYCOM RING DETECTOR .............................................................................. 3
GETTING STARTED - QUICK CONFIGURE & TEST ..................................................................................... 4
ALGO SIP ENDPOINT WEB INTERFACE CONFIGURATION ........................................................................ 5
8128/8138 WEB CONFIGURATION ........................................................................................................... 6
8180 WEB CONFIGURATION .................................................................................................................... 7
8180G2 WEB CONFIGURATION ................................................................................................................ 8
8186/8188/8189/8301 WEB CONFIGURATION ........................................................................................ 9
WIRING CONNECTIONS ........................................................................................................................ 10
TRIGGERING MULTIPLE DEVICES .......................................................................................................... 14
TESTING ............................................................................................................................................... 15
TROUBLESHOOTING............................................................................................................................. 15
WIRING CONNECTIONS ......................................................................................................................... 15
HEADSET JACK ..................................................................................................................................... 15
PHONE VOLUME .................................................................................................................................. 15
Document 90-00082J Algo Communication Products Ltd (604) 454-3792 2019-10-30 4500 Beedie St Burnaby BC Canada V5J 5L2 support@algosolutions.com Page 3 www.algosolutions.com
About the Algo 2506 Polycom Ring Detector
Polycom VVX phones can be configured to provide ring audio to the headset jack instead of the speaker. The Algo 2506 module detects the low-level audio from the headset jack and provides an isolated signal to activate an Algo SIP endpoint.
Only one compatible Algo SIP Endpoint can be connected directly to the 2506 Polycom Ring Detector at a time. However, any of the four devices can relay a signal to additional devices via the relay output connections on the back or via multicast.
What is Included
2506 Polycom Ring Detector
Coiled Handset Cord
Wires
What is not Included
Algo SIP Endpoint (see list below for compatible devices).
Compatible Algo SIP Endpoints
8128 SIP Strobe Light
8138 SIP Multicolored Strobe
8180 SIP Audio Alerter
8186 SIP Horn Speaker
8188 SIP Ceiling Speaker
8189 SIP Surface Mount Speaker
8301 Paging Adapter & Scheduler
Document 90-00082J Algo Communication Products Ltd (604) 454-3792 2019-10-30 4500 Beedie St Burnaby BC Canada V5J 5L2 support@algosolutions.com Page 4 www.algosolutions.com
Getting Started - Quick Configure & Test
This guide provides important safety information which should be
read thoroughly before permanent setup.
1. First configure the device via the web interface, as per the
instructions in this guide. Next, test that the configuration is correct by shorting a pair of wires to the input on the back of the device.
2. Connect one end of a wire pair (maximum length of 20 feet) to the
“+” and “-screw input terminals on the 2506 and the other end to the relay terminals on the Algo alerting device. The pin polarity and placement varies between devices. Refer to the guide for more information.
3. Connect the Algo alerting device to the network via an Ethernet cable
at the back of the device. Ensure that a PoE port is used for power.
4. Plug one end of the coiled handset cord into the RJ jack on the 2506
and the other end into the HEADSET jack on the Polycom phone.
5. Set the ring signal on the phone to be sent to the headset jack.
6. Set the VVX Polycom phone ringing volume to maximum.
(Ensure that the headset is set up before the ring volume is configured.)
7. When an incoming call is received by the Polycom VVX phone, an
audio/visual alert will be triggered.
Document 90-00082J Algo Communication Products Ltd (604) 454-3792 2019-10-30 4500 Beedie St Burnaby BC Canada V5J 5L2 support@algosolutions.com Page 5 www.algosolutions.com
Algo SIP Endpoint Web Interface Configuration
The compatible Algo SIP Endpoint web interface should be configured
before any wiring connections are made to avoid damaging the 2506.
Connect the Algo SIP Endpoint to the network via an Ethernet cable at the back of the device. Ensure that a PoE port is used for power.
After boot up, the device will beep and the intercom will have obtained an IP address. If there is no DHCP server the device will default to the static IP address 192.168.1.111.
Directions to obtain the IP address of the SIP device can be found in the product specific documentation. The IP address may also be discovered by downloading the Algo locator tool to find Algo devices on your network: www.algosolutions.com/locator