ASK-T TYPICAL INSTALLATION
COUNTERTOP CUTOUT REQUIREMENTS
NOTE:
HOT & COLD WATER SUPPLY AS WELL AS
A DRAIN MUST BE PROVIDED INSIDE THE
COUNTER FOR PROPER ASK-T HOOKUP.
ASK-T
UNIT
MOUNTING
HOLE
14"
FRONT VIEW
2" TO
26 5/8"
3 1/8"
(2X) 1/2" NPSM OR
3/8" COMPRESSION
WATER SUPPLY
1/2"
2 7/8"
1" NPSM
DRAIN
C
2" TO
C
L
BACK VIEW
L
8 1/8"
1"
5 9/16"
3 1/2"
23"
3 5/8"
MIN.
13 1/4"
10 1/4"
PAPER
TOWEL
HOLDER
BULLNOSE
NOTCH
DETAIL
13 1/2"
21 1/4"
CUTTING
BOARD
DEPTH EQUAL
TO BULLNOSE
OVERHANG
SUPERIOR EQUIPMENT SOLUTIONS
7039 EAST SLAUSON AVENUE
COMMERCE, CA. 90040
LAST SAVED BY: »» adrian «« July 13, 2007 3:42:50 PM
THE INFORMAT ION CONTAINED IN T HIS DRAWING IS THE
SOLE PROPERTY OF SUPERIOR EQUIPMENT SOLUTIONS
INC. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT WRITTEN PERMISSION FROM SUPERIOR
EQUIPMENT SOLUTIONS, INC. IS PROHIBITED.
DRAWN BY:
CREATED:
ADRIAN CRISCI
June 11, 2007 3:05:45 PM
1/2"
NOTCH
13 1/4"
PROJECT TITLE:
DRAWING TITLE:
ASK-T
ASK-T PREP/WASH SINK SPECIFICATIONS
NOTCH1/2"
DRAWING NO.:
ASK-T SPEC SHEET
SHEET 1 OF 1