Alfa Laval LKAP Instruction Manual

ESE01993-EN6 2016-07
Original manual
Instruction Manual
LKAP Air-Operated Valve
Table of contents
The information herein is correct at the time of issue but may be subject to change without prior notice
2. Safety .................................................................................................... 5
2.1. Important information .............................................................................
5
2.2. Warningsigns .....................................................................................
5
2.3. Safetyprecautions ................................................................................
6
3. Installation .............................................................................................. 7
3.1. Unpacking/delivery ...............................................................................
7
3.2. General installation ................................................................................
7
3.3. Welding ............................................................................................
9
3.4. Recycling information .............................................................................
10
4. Operation ............................................................................................... 11
4.1. General operation .................................................................................
11
4.2. Faultfinding .......................................................................................
11
4.3. Recommendedcleaning .........................................................................
12
5. Maintenance ........................................................................................... 13
5.1. General maintenance .............................................................................
13
5.2. Dismantling ........................................................................................
14
5.3. Assembly ..........................................................................................
16
6. Technical data ......................................................................................... 19
6.1. Technical data .....................................................................................
19
7. Parts listandservice kits ............................................................................ 21
7.1. LKAP-V and LKAP-T air-operatedvalves with welding ends .................................
22
3
1 EC Declaration of conformity
Revision of Declaration of Conformity 2009-12-29
The Designated Com
pany
Alfa Laval Koldin
gA/S
Company Name
Albuen 31, DK-6000 Kolding, Denmark
Address
+4579322200
Phone No.
hereby declare that Valve
Designation
LKAP
Typ e
is in conformity with the following directive with amendments:
- Machinery Directive 2006/42/EC
- Pressure Equipment Directive 2014/68/EU category 1 and subjected to assessment procedure Module A.
The person authorised to compile the technical file is the signer of this document
Global Product Quality Manager
Pumps, Valves, Fittings and Tank Equipment Lars Kruse Andersen
Title Name
Kolding
2016-06-01
Place Date Signature
4
2 Safety
Unsafe practices and other important information are emphasized in this manual. Warnings are emphasized by means of special signs.
2.1 Important information
Alwaysreadthemanualbeforeusingthevalve!
WARNING Indicates that special procedures must be followed to avoid serious personal injury.
CAUTION Indicates that special procedures must be followed to avoid damage to the valve.
NOTE Indicates important information to simplify or clarify procedures.
2.2 Warning signs
General warning:
Caustic agents:
5
2 Safety
All warnings in the manual are summarized on this page. Pay special attention to the instructions below so that severe personal injury and/or damage to the valve are avoided.
2.3 Safety precautions
Installation: Always observe the technical data (see section 6 Technical data) Always release co
mpressed air after use. Never touch the clip assembly or the actuator piston rod if the actuator is supplied with compressed air. Never touch the valve or the pipelines when processing hot liquids or when sterilizing. Never dismantle the valve with valve and pipelines under pressure. Never dismantlethevalvewhenitishot.
!
Operation:
Never disman
tle the valve with valve and pipelines under pressure. Never dismantlethevalvewhenitishot. Always observe the technical data (see section 6 Technical data) Always release compressed air after use. Never touch the valve or the pipelines when processing hot liquids or when sterilizing Never touch the clip assembly or the actuator piston rod if the actuator is supplied with compressed air.
!
Always handle lye and acid with great care
Maintenance:
- Always observe the technical data (see section 6 Technical data)
- Always release compressed air after use
- The valve must never be hot when servicing it
- The valve/actuator and the pipelines must never be pressurised when servicing the valve/ actuator
- Never stick your fingers through the valve ports if the actuator is supplied with compressed air.
- Never touch the clip assembly or the actuator piston rod if the actuator is supplied with compressed air.
!
Transportation:
Always secure that compressed air is released Always secure that all connections is disconnected before attempt to remove the valve from the installation Always drain liquid out of valves before transportation Always used predesigned lifting points if defined Always secure sufficient fixing of the valve during transportation - if special designed packaging material is available it
mu
st be used
6
3 Installation
The instruction manual is part of the delivery. Study the instructions carefully. LKAP-V: Valve body wit two valve ports. LKAP-T: Valve body with three valve ports.
3.1 Unpacking/delivery
Unpacking/delivery Step 1 CAUTION Alfa Laval cannot be held responsible for incorrect unpacking.
Check the delivery:
1. Complete valve, LKAP-V or LKAP-T
2. Delivery note
3. Instruction manual
Step 2
1. Clean the valve for possible packing materials
2. Inspect the valve for visible transport damage
3. Avoid damaging the valve
3.2 General installation
Step 1
Always read the technical data carefully. See section 6 Technical data
Always release compressed air after use.
CAUTION Alfa Laval cannot be held responsible for incorrect installation.
Step 2 Flow direction:
To avoid pressure shocks it is recommended to install the valve with inlet through the bottom connection.
-A:Inlet
-B:Outlet
A
B
TD 402-034_1
A
B
TD 402-035_1
Step 3 Avoid stressing the valve.
-Vibrations
- Thermal expansion of the tubes
- Excessive welding
- Overloading of the pipelines
TD402-018_1
Risk of damage!
7
3 Installation
Study the instructions carefully and pay special attention to the warnings! The valve has welding
ends as standard but can also be supplied with fittings. NO = Normally open. NC = Normally closed.
Step 4 Fittings: Ensure that the connections are tight (remember seal rings).
TD402-019_1
Step 5 Air connection: R 1/8” (BSP).
NO
Air
NC
TD402-013_1
8
Loading...