Alemite 8430 Service Manual

Service Guide
1/3 HP DEF Pump
Description
Self-priming pumps for Diesel Exhaust Fluid (DEF) ap-
plications
• Built-in handle for portability and ease of handling.
• Suction lift capability to 15 ft.
WARNING
For proper and trouble-free operation of this DEF pump, it is important to carefully read and follow these operating instructions and to fully observe all warn­ings. For safety reasons, people who are not familiar with these operating instructions should not use the pump, especially children under the age of 16. Before installing or servicing any pump, be certain pump power is disconnected to avoid any possible electric shock. Conformity with federal, State and local electric codes are mandatory. The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying sump, utility, effl uent and all DEF pumps. Consult a licensed electrician or your power company if in doubt.
8430
Figure 1 Model 8430 DEF Pump
Installation
Before putting the pump into operation it is absolutely
necessary to carry out the following operations:
1. The diameter of the suction and lines should correspond to the diameter of the connections of the pump housing (1”). See fi gure 2. For a suction height of over 12 ft., a suction hose with a greater diameter should be used.
2. Fit the suction lines with the foot valve to the pump (at point 1, Fig 2), avoiding siphons, counter slopes and stand the pump on solid, fl at level ground.
3. Fit the delivery line (at point 2, Fig 2).
4. Put into operation the pump and wait for the suction of the DEF. If nothing occurs after 2-3 minutes, switch off the pump, unplug and repeat the whole operation. It will be
Alemite, LLC
167 Roweland Drive, Johnson City, Tennessee 37601
www.alemite.com
Copyright © 2012 by Alemite, LLC
671035
This document contains confi dential information that is the property of Alemite, LLC
1) 1” Suction NPT
2) 1” Discharge NPT
3) Inspection Plug
4) Prime/Drain Plug
Figure 2 8430 (115V/60Hz)
SER 8430
Revision (7-12)
SER 8430
DEF Pump
necessary to recheck pump’s installation. When checking operations, always remember to take out the drain plug (point 4, Fig 2). Possible causes for loss of prime may be a leak in packaged product valve or down tube suction line letting air in, faulty foot or check valve, suction line not completely submerged or damaged, too high suction lift clogged suction fi lter or closed outlet.
5. For all electrical connections, a separate line with a fuse switch should be run from the meter or breaker box and properly grounded.
6. Open all shut-off devices in the pressure system of the pump (e.g.) DEF nozzle, so that air can escape during the priming operation
7. The temperature of the DEF must never exceed 35° C or 100° F.
8. Always unplug the pump before working on it, in case of maintenance.
9. Do not place or submerge the pumps into water.
10. Always use a suction line with an installed check valve or
foot valve; this will allow ease priming when starting the pump.
• Always disconnect electricity to the unit before handling it.
• Do not lift the unit by the power cord.
• Do not pump heated liquids. Max. Temperature 35° C or 100° F.
• Conformity with local and State electric codes is mandato­ry. Consult a licensed electrician or your power company if in doubt.
• Power cables as well as extension cables may be done us­ing same cord type.
• Take care that connections are done in areas protected from fl ooding.
• Before installation please check for any damage to the unit (e.g. power cable and plug).
Before Operating
• The unit is supplied with a grounding conductor and a grounding type plug.
• To reduce risk of electric shock, connect only to a properly grounded electrical circuit equipped with an interrupter device. For all electrical connections, a separate line with a fuse or circuit breaker switch should be run from the meter, or breaker box, and properly grounded.
• Do not remove the grounding pin from the plug.
• This pump is designed for 115- Volt - 60 Hz operation Be Sure the supply voltage is the same.
• Never pump gasoline or other fl ammable liquids or oper- ate in the areas where fl ammable or explosive fumes are present as fi re or explosion could occur.
• Unit features can be read on one side of its packaging.
• Piping must be protected against freezing which will cause damage and void the warranty.
• Do not run pump dry. If the pump is run dry, damage will result and void the warranty.
• This pump must be primed before running.
General Safety
• Read all instructions carefully and thoroughly be­fore operating, maintaining or servicing the unit.
• Be sure that electrical power supply conforms to the power requirement of the unit. Refer to “Specifi cations”.
• Do not exceed pressure rating of system compo­nents.
• Do not make system components adjustments that are not recommended in this service sheet. When in doubt, consult Alemite service representatives or personal familiar with instrumentation.
• Electrical service must be performed by an elec­trician or personnel familiar with instrumentation.
• Shut off electrical power to the unit before doing service on the unit.
Revision (7-12) Alemite LLC
2
DEF Pump
SER 8430
Figure 3 8430 - exploded view
3
Revision (7-12)Alemite LLC
Loading...
+ 5 hidden pages