Alcott Hill RDBS7454 Assembling & Installation Instructions

ASSEMBLING & INSTALLATION INSTRUCTIONS
(
)
(
)
The drawing shown may not exactly match the product enclosed.
However, the installation instructions do apply to this product.
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER. ATTENTION! COUPER LE COURANT AU FUSIBLE OU UN DISJ ON CTEUR.
ASSEMBLING THE FIXTURE (Fig.2)
2. Attach the check ring(K) insert to the socket wrench(I), attach the clear glass(M) and
3. Install the light bulbs(not included) in accordance with the fixture’s specifications.
HANGING THE FIXTURE (Fig.1)
1. Shut off the power at the circuit breaker and remove old fixture from ceiling, including
2. Carefully unpack new fixture and lay all the parts on a clear surface.
3. Thread nipple (C) into loop (F) until snug.
4. Thread other end of nipple (C) with loop attached into single bar (D) until snug.
5. Place lock washer (B) over end of nipple protruding through single b ar and thread he x
6. Take this single bar assembly and mount to ceiling junction box with junction box
7. Using proper chain pliers to open one end link of the chain provided and connect to the
8. By measuring, determine correct number of links needed for proper hanging height.
9. Lace the fixture wires through the chain.
10. Slip loop collar (H) over the chain, then do the same with the canopy (G).
11. Open the other end link of the chain and hang the fixture on the loop at the ceiling .
12. Feed the fixture wires through the loop (F) and nipple (C) and pull until taut.
CONNECTING THE WIRES (Fig.3)
1. Take the black wire from the ceiling junction box and the smooth wire leg from the
2. Repeat same process with white junction box wire and ribbed wire leg of fixture wire.
3. If your junction box has a grounding wire (green or bare copper), attach this wire and
4. Tuck these wire connections neatly into the ceiling outlet box and then raise the
Your installation is now complete. Return power to the junction box and test the fixture.
tighten. opal glass(L) to the lamp holder, lock the m securely with the socket wrench(I), then
remove the socket wrench and save it. NOTE: DO NOT EXCEED THE SPECIFIED WATTAGE!
the old single bar. Shut off the power at the circuit breaker and remove old fixture from ceiling, including the old single bar.
nut (A) onto nipple until tight. screws (E). Tighten screws securely with screwdriver. fixture loop. Close the link. Using proper chain pliers disconnect and discard remaining chain.
Close the link.
fixture and twist bare ends together. Twist wire connector onto end of wire until snug. NOTE: Twist wires together in the same direction you twist the wire connector onto
wires. the bare copper wire from the fixture together as step 1.If junction box has no ground
wire, attach the bare copper fixture wire to the green ground screw on the crossbar. canopy (G) all the way to the ceiling. Raise the loop (H) and thread onto ceiling loop
protruding through canopy.
FIG.3
©COYRIGHT ALL RIGHTS RESERVED.
FIXTURE WIRES
BLACK
HOUSE WIRES
Black
Hot
Thank you for purchasing our product.
Need assistance with parts or assembly? Please call customer service
FIXTURE WIRES WHITE
HOUSE WIRES
White Neutral
FIG.1FIG.2
FIXTURE WIRES GREEN
Thread
(Ground)
Green or
Copper(Ground)
HOUSE WIRES
Bare
Loading...