IMPORTANT
Templates must be printed without size modifications
and verified for dimensional accuracy.
• Before printing, select the printing options necessary
to ensure that copies are produced without size
adjustments.
• After printing, measure the dimensions indicated on
the template to ensure correct scale.
ET-PDL
Trilogy ® Panic Exit Device Trim
INSTRUCTIONS & TEMPLATE
Battery
Box Cover
Battery
Pack
Battery Box
Mounting Plate
Sargent
Model 8812
1.532"
TWO
THRU-
BOLT
HOLES
5/16"
DRILL BOTH
SIDES
ETDL
SERIES
ETPDL
SERIES
Sargent
W
E
N
To Change Cylinder
Model 8812
Rim Exit Device
IMPORTANT:
When replacing cylinder
be sure to use the
proper Cylinder Adapter
and Tailpiece.
Alarm Lock Systems, Inc.
A division of the NAPCO Security Group
345 Bayview Avenue, Amityville, NY 11701
Tel: (631) 789-4871 Fax: (631) 789-3383
www.alarmlock.com
Publicly traded on NASDAQ Symbol: NSSC
1
1. Existing Installation: Remove Exit device from door.
Note: The
spindle
hole must
be no less
than 1"
diameter
2
2. Existing Installation: Position Alarm Lock template on
horizontal & vertical lines of existing spindle hole.
New Installation: Locate and mark horizontal and vertical
lines indicated in Exit Device Instructions/Template. Line up
Alarm Lock template with horizontal and vertical lines and
tape on door.
Existing and New Installations: Mark all hole centers on
each side of door. Drill all holes from both sides of door to
avoid splintering.
A
A. Remove Cover plate. Rotate the
spindle either direction to expose
and remove cylinder screws.
3
3. Position Exterior assembly on door.
Two Shoulder
mounting screws
Two #10 x 1¼"
flat head selftapping screws
Two Shoulder
mounting screws
Two #8 x 3/4"
flat head sheet
metal screws
4
4. Replace Exit Device, insert and fasten with 2 new Shoulder
mounting screws, on top of Exit Device into mounting posts.
Fasten two #10 x 1-1/4" flat head sheet metal screws in
lower mounting holes. Do not over-tighten. Pull wires from
door through Battery Mounting Plate. Do not pinch or cut
wires. Position plate below Exit Device and fasten with two
Shoulder screws on top, into mounting posts and two #8 x
3/4" flat head sheet metal screws on the bottom.
B
B. Remove old cylinder and insert new cylinder.
5
5. Connect battery pack and place inside of battery mounting
plate. Position cover and fasten with three #6-32 x 5/16"
screws.
6
6. Replace and fasten Exit device & Battery box covers.
Check lock for proper operation
before closing door.
TailPiece
C
C. Note: The tailpiece must be in the
horizontal position as shown in the
image above.
RECOMMENDED
HORIZONTAL
LINE OF
EXIT DEVICE
1.850"
TWO HOLES
INTERIOR ONLY
FOR EXIT DEVICE
INSTALLATION
Drill 3/32" hole
1-1/4" deep for
#10 flat head
sheet metal
screws
4.840"
TWO THRU-
BOLT HOLES
(FOR BATTERY
MOUNTING
PLATE)
5/16"
DRILL BOTH
SIDES
WIRES
HOLE
1/2"
DRILL BOTH
SIDES
VERTICAL LINE
1.532"
1.375"
4.920"
SPINDLE
HOLE
1"
MINIMUM
DRILL BOTH
SIDES
4.025"
WI 1121A-NS8 10/07
© ALARM LOCK 2007
6.690"