C3000/B                                     2785...…  
AKG Service Department, Lemböckgasse 21-25, A-1230 Wien, Austria.Tel.: (431)86654-0, FAX: (431)86654-1514, e-mail: service@akg.com   01/13 
  C3000B ….2785Z00110 (metallic)     
  C3000 ……2785Z00130/X00230 
7.1 
7 
10 
6 
4.1 
4 
12,13 
11 
2 
Description 
Item 
Pos. 
3 
Part number 
Bestellnummer 
7.2 
8 
Quant. 
Stk.
C3000B C3000 
7.3 
1 
9 
Bezeichnung 
Housing  1  2785Z02110  1  -  Gehäuse  
Housing  1  2785Z02130  -  1  Gehäuse  
Cap, complete  2  2785M03010  1  -  Kappe, komplett 
Cap, complete  2  2785M03020  -  1  Kappe, komplett  
Capsule carrier  3  2785Z04020*)  1  1  Trägerrahmen 
Electret capsule CE6  4  2512M99050  1  1  Elektretkapsel CE6 
Suspension  4.1  2820Z14010  1  1  Aufhängung 
Contact holder  6  2785M02020*)  1  1  Kontakhalter 
Main board, compl.  7  2785L01010  1  1  Print, komplett 
Switch  7.1  0040E01830  2  1  Schalter 
Contact strip, 8-pole  7.2  0018E08200  1  1  Kontaktsatz, 8 polig 
XLR – insert  7.3  0016E03460  1  1  XLR - Stecker 
Switch cover  8  2785Z09010  2  1  Schalterblende 
Colour ring  9  2785Z07010  1  -  Farbring 
Colour ring  9  2785Z07020  -  1  Farbring 
Popshield  10  2785Z08010  1  1  Windschutz 
Screw M3x8  11  7500D30000  2  -  Sch raube M3x8 
Screw M3x8  11  7500D30010  -  2  Schra u b e M3 x8 
Screw M2,5x6  12  7045D25000  1  -  Schraube M2,5x6 
Screw M2,5x6  12  7500D25020  -  1  Schraube M2,5x6 
Toothed washer  13  6797D25000  1  -  Zahnscheibe  
Toothed washer  13  6797D25010  -  1  Zahnscheibe 
Shock mount H85  --  6001H30140  1  1  Spinnenhalterung H85 
Metal case  --  3828P05030  1  1  Metallkoffer 
*) Former versions 2785Z0401 and 2785M0201 can equally be used  
*) Frühere Varianten 2785Z0401 und 2785M0201 können gleichermaßen verwendet werden 
The capsule (4) is delivered with elastic suspension, membrane contact and wires.  
Parts (6) and (3) are snapped together. To separ ate the m, put the complete capsul e carrier into cap (2) until it sits 
properly on it's circumf erence. Then inser t a suitable sc rewdr iver into o ne of the slo ts next to the contact pins and 
using a light weight hammer knock the carrier out from the contact holder. Then p roceed with the second slot. 
After both latches of the carrier (3) ar e disengaged, the capsule carrier can be pulle d out from the contac t holder 
(6). 
Besides of the parts mentioned in the parts list there are no components available for the printed circuit board (7). 
Repair Hints: 
1/3