Akerstroms Bjorbo S506 Installation manual

INSTALLATION MANUAL SESAM 506 92 7123-000 Ver. A0 Page 1(2)
Incoming
SESAM 506- Door opening system
TRANSMITTER
The transmitter operates on a 9V alkaline battery. Pushbutton 1, 4 = OPEN, button 2, 5 = CLOSE, button 3, 6 = STOP
RECEIVER
All that fuses are used as separation devices. They must be easily accessible, must submit a contact-gap of at least 3.0 mm and has to be placed in the line pole (L).
After the installation of the equipment, the installed cables must be bound together (e.g. by using a cable binder) very close to the terminal blocks.
If the receiver is mounting unprotected for rain it must be mounted horizontally.
Figur 1. Receiver 3 functions
CODING
The receiver and the transmitter have to be coded by the electrician. The transmitter and receiver are provided with 10-pole switches SW1 with 3 possible positions (+, 0, -).
Switch 1-3
The code is divided into two parts, area code and door code. The area code (switch 1-3) has to be identical for all the transmitters and the receivers, which are to be working together.
Switch 4-10
Door codes are coded as example below.
Transmitter
Corresponding port number in the receiver
gives Upper line Lower line
voltage 115 VAC
In areas with more than 2 ports you have to code after the table. Switch 1-6 are coded identically in transmitter and receiver. The upper button line on the transmitter correspond to the lower portĀ­number in the table. The lower button line on the transmitter correspond to the upper portnumber in the table.
FCC Identifier OG4S506
INSTALLATION MANUAL SESAM 506 92 7123-000 Ver. A0 Page 2(2)
Coding example receiver
Coding port 16. Code as illustration (9+6+1=16)
The receivers code for port 16. The upper line in transmitter 506.
Coding port 17. Code as illustration. (9+6+2=17).
PLUG IN
Coding see above.
Plug in receiver
Incoming voltage 12-24 VAC or DC is connected to pin 5 and 6 (independent polarized). What concerns the relay outputs see figure
2.
For 1-relays receiver
With switch SW2 You can choose which push button on the transmitter which have to set function out on the receiver sees below.
The receivers code for port 17. The lower line in transmitter 506.
Figur 2. Receiver with 1 respective 3 functions
PLUG IN TRANSMITTER 506 SW2:1 ON other OFF Button 1, 4 SW2:2 ON other OFF Button 2, 5 SW2:3 ON other OFF Button 3, 6
Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
FCC Identifier OG4S506