A.J. Antunes & Co UFL-440, 9700475 User Manual

Page 1
MANUFACTURING
9700465 9700475
System Tested and Certified by NSF
International and WQA against NSF/ANSI
Standard 42 and 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Nominal Particulate Reduction Class I
Standard No. 53: Health Effects
Cyst Reduction & Turbidity Reduction as
verified and substantiated by test data.
System Tested and Certified by WQA
against NSF/ANSI Standard 372
for lead-free compliance
P/N 1011055 Rev. F 12/13
WATER FILTRATION
SYSTEM
UFL-420/440 Series
Owner’s Manual
Page 2
UFL-420/440 WATER FILTRATION SYSTEM
TABLE OF CONTENTS
Owner Information .....................................................2
General ......................................................................2
Warranty Information .................................................2
Service/Technical Assistance ....................................3
Important Safety Information ....................................4
Important Safety Information ....................................5
Specifications .............................................................6
Dimensions ................................................................6
Replacement Cartridges ............................................6
Electrical Ratings .......................................................6
Electrical Cord & Plug Configurations .......................6
Performance Data Sheet ............................................ 8
Ultra Filter Cartridge Capacities ................................8
System Capacities .....................................................8
Performance Claims for Percent Reduction ..............8
Overview......................................................................9
Overview ....................................................................9
Manual Flushing ........................................................9
OWNER INFORMATION
General
Installation .................................................................10
Unpacking ................................................................10
Equipment Setup .....................................................10
Mounting the System ...............................................11
Inlet Water Plumbing ...............................................11
Permeate Line Plumbing .........................................12
Drain Valve Connection ...........................................12
Starting the Controller .............................................13
Rinsing the Ultra Filter Cartridge .............................13
Sanitizing the System and Lines .............................14
Maintenance ..............................................................15
Replacing the Ultra Filter Cartridge .........................15
System Sanitization .................................................15
Changing the Interval Setting ..................................16
Resetting the Timer Program ..................................16
Troubleshooting .......................................................17
Replacement Parts .................................................. 18
Limited Warranty ......................................................20
Warranty Information
The UFL Series reduces cysts and turbidity that can enter a typical water supply. This patented technology is now available to you, sized for your particular appli­cation. All filter configurations utilize NeoH capillary membranes, providing the latest innovation in reusable surface filtration technology.
This manual provides the safety, installation and operating procedures for the UFL Series water filtration systems. We recommend that all information contained in this manual be read prior to installing and operating the unit.
Your UFL Series unit is manufactured from the finest materials available and is assembled to AFT’s strict quality standards. This unit has been tested at the factory to ensure dependable trouble-free operation.
Please read the full text of the Limited Warranty in this manual.
If the system arrives damaged, contact the carrier immediately and file a damage claim with them. Save all packing materials when filing a claim. Freight dam­age claims are the responsibility of the purchaser and are not covered under warranty.
The warranty does NOT extend to:
• Damages caused in shipment or damage as result of improper use.
• Installation of electrical service.
• Normal maintenance as outlined in this manual.
• Malfunction resulting from improper maintenance.
• Damage from moisture leaking into electrical components.
• Damage from tampering with, removal of, or changing any preset control or safety device.
IMPORTANT! Keep these instructions for future reference. If the unit changes
ownership, be sure this manual accompanies the equipment.
2
P/N 1011055 Rev. F 12/13
Page 3
UFL-420/440 WATER FILTRATION SYSTEM
OWNER INFORMATION (continued)
Service/Technical Assistance
If you experience any problems with the installation or operation of your unit, contact A.J. Antunes & Co. at 1-630-784-1000, or toll free in the United States at 1-800-253-2991.
Fill in the information in the next column and have it handy when calling for assistance. The serial number is on the specification plate located on the unit.
Purchased From:
Date of Purchase:
Model No.:
Serial No.:
Mfg. No.:
Suggested replacement period for Ultra Filter Cartridge is approximately 3 years.
For sales in the state of Iowa:
Seller: Date:
Buyer: Date:
IMPORTANT
A.J. Antunes and Co. reserves the right to change specifications and product design without
notice. Such revisions do NOT entitle the buyer to corresponding changes, improvements,
additions or replacements for previously purchased equipment.
P/N 1011055 Rev. F 12/13
3
Page 4
UFL-420/440 WATER FILTRATION SYSTEM
IMPORTANT SAFETY INFORMATION
In addition to the warnings and cautions in this manual, use the following guidelines to safely operate the sys­tem:
• Read all instructions before using equipment.
• Install or locate the equipment only for its intend­ed use as described in this manual.
• Do NOT use corrosive chemicals in this equip­ment.
• Do NOT operate this equipment if it has a dam­aged cord or plug; if it is not working properly, or if it has been damaged or dropped.
• This equipment should be serviced by qualified personnel only. Contact A.J. Antunes & Co. for repair.
• Do NOT immerse cord or plug in water.
• Keep cord away from heated surfaces.
• This equipment should be supplied with only cold water.
• For installations in Massachusetts, the Commonwealth of Massachusetts Plumbing Code 248 CMR shall be adhered to. The use of saddle valves are not permitted. Please consult your local plumber.
The following warnings and cautions appear throughout this manual and should be carefully observed.
• Unplug the power cord before performing any service or maintenance on the unit.
• All electrical connections must be in accordance with local electrical codes and any other appli­cable codes.
• WARNING ELECTRICAL SHOCK HAZARD. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH.
- Do NOT modify the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.
- Do NOT use an extension cord with this unit.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a simi­larly qualified person.
• This equipment is to be installed to comply with the local plumbing code and any other applicable code.
• Water pressure must not exceed 100 psig (690 kPa). To reduce water pressure, install a water pressure regulator and set to suit the application.
• The trans membrane pressure (inlet pressure minus the permeate water pressure) must not exceed 45 psi (310 kPa).
• A ground fault circuit interrupter (GFCI) must be installed on the circuit to this system.
• When installed on metallic plumbing, a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this unit.
NOTE: If the inlet water pressure is less than 50 psig (345 kPa), it is recommended that a suitably­sized booster system (outlet pressure 60 psig - 100 psig max (414 kPa - 690 kPa max) be installed.
4
P/N 1011055 Rev. F 12/13
Page 5
UFL-420/440 WATER FILTRATION SYSTEM
IMPORTANT SAFETY INFORMATION
Protect from becoming dry
If the membrane dries out, irreversible damage to the Ultra Filter membrane may result. Protect the filter from becoming dry by keeping it wet and sealed at all times.
Protect from freezing
If the Ultra Filter membrane freezes during operation or storage, irreversible damage to the membrane and brittle cracking of the cartridge or housing may result.
Protect from direct sunlight or other UV sources
Avoid long-term exposure to direct sunlight or other UV sources. The Ultra Filter should be stored in a dark location.
Protect from high temperatures or abrupt variation in temperature
The maximum operating temperature is 100°F (38°C). Avoid abrupt variations in temperature. Any temperature variation should be made slowly.
Protect from rough handling or dropping
Mechanical damage, external breakage, and/or internal breakage of the filter can result if the system is dropped or bumped. Handle with care at all times during trans­portation and installation.
Protect from organic solvents and concentrated acids
Prevent any and all contact of the membrane with strong solvents, solvents containing chlorine, or con­centrated acids. Do NOT use strong solvents or con­centrated acids on any plastic parts of the filter system. Examples of some solvents to avoid: acetone, methyl acetate (nail polish remover); hexane (spot removers); turpentine, toluene (paint thinners); dry cleaning solu­tions, insecticides.
CAUTION This equipment is to be installed to comply with the basic plumbing code of the Building Officials and Code Administrators, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
CAUTION Water Flow Regulator Assemblies are NOT inter­changeable. Operating the system with the wrong Water Flow Regulator or without a regulator can damage the system, cause personal injury, and voids the warranty!
CAUTION All electrical connections must be in accordance with local electrical codes and any other appli­cable codes.
A ground fault circuit interrupter (GFCI) must be installed on the circuit to this system.
When installed on metallic plumbing, a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this unit.
Protect from abrasive material
The membranes must be protected from abrasive materials like shavings left in a pipe. Abrasive materials in contact with the membrane can cause irreversible damage to the membrane. All pipes must be flushed clean before installing the filter. All plastic parts of the filter system must be protected from sharp objects like knives, sand paper, or other tools. Cutting or nicking a plastic part can weaken it and cause a leak. Do NOT use abrasive cleansers on any plastic parts.
Protect from water hammer
The system must be protected from shock, pressure surges, or pulsation that may occur inside water pipes. Water hammer occurs in pipes when a valve or faucet shuts quickly. Install a water hammer arrestor (pressure vessel containing compressed air separated from the water by a diaphragm) to reduce pressure shock.
P/N 1011055 Rev. F 12/13
5
Page 6
UFL-420/440 WATER FILTRATION SYSTEM
SPECIFICATIONS
Dimensions
C
UFL-420 UFL-440
A
A
C
B
Electrical Ratings
Model &
Mfg. No.
UFL-420 9700465
UFL-440 9700475
Electrical Cord & Plug Configurations
Kit Model
Number
Voltage Watts Amps Hertz
100–240 10 0.4 50/60
100–240 10 0.4 50/60
Description Configuration
DC Power Supply
100 - 240 VAC
0012146
Includes the
4 plug adaptors
below
NOTE: PLUG STYLE MAY VA RY
US
NEMA 1-15 (2 pin)
or NEMA 5-15
(3 Pi n)
B
Euro
CEE 7/16
Model &
Mfg. No.
UFL-420 9700465
UFL-440 9700475
Replacement Cartridges
Width
(A)
11.5”
(29 cm)
11.5”
(29 cm)
Depth
(B)
6”
(15 cm)
6”
(15 cm)
Height
(C)
28”
(71 cm)
47”
(119 cm)
Replacement Cartridge Part No.
UFL-420 L-420 Ultra Filter 7000411
UFl-440 L-440 Ultra Filter 7000412
Operating
Weight
28 lbs.
(12.7 kg)
42 lbs.
(19 kg)
AS/NZS
3112 AUS
(2 Pi n)
UK
BS 1363
CAUTION All electrical connections must be in accordance with local electrical codes and any other applicable codes.
A ground fault circuit interrupter (GFCI) must be installed on the circuit to this system.
When installed on metallic plumbing, a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this device
6
P/N 1011055 Rev. F 12/13
Page 7
UFL-420/440 WATER FILTRATION SYSTEM
SPECIFICATIONS (continued)
Permeate
Outlet
Drain Valve
Filter
Housing
Flush Button
Mounting
Bracket
Power
Transformer
Flow
Controller
Inlet
P/N 1011055 Rev. F 12/13
Figure 1. Components
7
Page 8
UFL-420/440 WATER FILTRATION SYSTEM
PERFORMANCE DATA SHEET
Filter Cartridge Capacities
Maximum Operating Pressure 100 psig (690 kPa) Maximum Operating Temperature 100°F (38°C) Minimum Operating Temperature 40°F (4°C) Maximum Trans Membrane Pressure 45 PSI (3.1 Bar) pH Range 3-10 MWCO 100 kD
NSF/WQA Certified Rated Service flow:
UFL-420 7.9 gpm (30 l/m)
UFL-440 13 gpm (49 l/m)
System Tested and Certified by NSF
International and WQA against NSF/ANSI
Standard 42 and 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Nominal Particulate Reduction Class I
Standard No. 53: Health Effects
Cyst Reduction & Turbidity Reduction
as verified and substantiated by test data.
System Tested and Certified by WQA
against NSF/ANSI Standard 372
for lead-free compliance
Performance Claims for Percent Reduction
Substance Influent
1
cyst
Turbidity 11 ± 1 NTU ≤ 0.5 NTU 99.1%
Particulate Class I
Particles 0.5 to <
1µm
1
based on the use of microspheres or Cryptosporium parvum oocysts
Challenge
Concentration
minimum 50,000/L
at least 10,000
particles /mL
Reduction
Requirement
99.95% 99.95%
≥ 85% N/A
Minimum
Reduction
%
This system has been tested according to NSF/ANSI Standard 42 and 53 for reduction of the substances listed below. The concentration of the indicated sub­stances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 or 53. While testing was performed under standard laboratory conditions, actual performance may vary.
NOTE: The NSF/WQA information provided applies to the Ultra Filter cartridge.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate dis­infection before or after the system. Systems certi­fied for cyst reduction may be used on disinfected waters that may contain filterable cysts.
8
P/N 1011055 Rev. F 12/13
Page 9
UFL-420/440 WATER FILTRATION SYSTEM
OVERVIEW
Overview
The UFL system operates in two modes:
• Normal Operation Mode
• Flush Mode
During Normal Operation Mode, water enters the Inlet and flows through the Ultra Filter before exiting the Permeate Outlet as usable product water.
During Flush Mode, the Drain Valve opens and water entering the Inlet flushes and cleans the Ultra Filter membrane by removing any debris collecting on the membrane wall.
The Drain Valve is only powered during Flush Mode.
NOTE: Do NOT unplug the power cord or turn off the system during Flush Mode. If there is a power outage or the system is unplugged, water will con­tinue to be filtered but the system will NOT flush. This could cause the Ultra Filter to plug premature­ly and may reduce the life of the filter.
The flush is automated by the controller to last 10 seconds and take place in one hour intervals. This interval can be changed (see Changing the Interval Setting in the Maintenance section of this manual).
CAUTION
Changing the flush interval can cause the Ultra Filter to plug prematurely and may reduce the life of the filter. Consult the factory for more informa­tion.
Manual Flushing
A manual flush can be activated at any time by pressing the FLUSH button on the Universal Pulse Controller.
When the FLUSH button is pressed, the Flush LED on the controller flashes and the Drain Valve opens for 10 seconds. After flushing is complete, the Drain Valve will close, the Flush LED will stop flashing and the unit will automatically return to Normal Operation Mode.
NOTE: A manual flush will not affect the interval flush setting.
Figure 2. UFL-420 System
P/N 1011055 Rev. F 12/13
9
Page 10
UFL-420/440 WATER FILTRATION SYSTEM
INSTALLATION
Unpacking
1. Remove the system and all packing materials from the shipping carton.
2. Remove all packing materials and protective cov­erings from the system
3. Remove the information packet. To prevent any delay in obtaining warranty coverage, fill out and mail the warranty card.
NOTE: If any parts are damaged, contact A.J. Antunes & Co. IMMEDIATELY at 1-800-253-2991 or 1-630-784-1000.
Equipment Setup
GENERAL
When placing the unit into service, pay attention to the following guidelines:
• Do NOT immerse cord or plug in water.
• Keep cord away from heated surfaces.
SUGGESTED TOOLS AND SUPPLIES FOR INSTALLATION
The following tools and supplies are suggested to make the installation easier:
• Screwdriver
• Drill with bits
• Tape measure
• Two gallon bucket
• Pipe wrenches
ELECTRICAL
• Adjustable wrenches
• Level
• Pipe dope or thread seal tape
• Fresh 5 1/4% liquid chlorine bleach
PLUMBING
NOTE: This unit is designed to use tap water not to exceed 100°F (38°C) or 100 psig (690 kPa).
The UFL-420 and UFL-440 systems use the following connections (Figure 1):
Water Inlet 1” NPT
Permeate (Product Water) 1” NPT
Drain 3/4” NPT
When making a plumbing connection to the system, remember to use a back-up wrench on the supporting plumbing. Always use a good quality, approved pipe sealant or thread seal tape on pipe threads. Be careful not to get the pipe sealant inside the pipe when making the connections.
Do NOT over tighten the connections. It is recommend­ed that plastic fittings be used when connecting to the plastic connections of the system. This will reduce the possibility of cracking the connections due to overtight­ening.
If soldered plumbing is used, do NOT apply heat to, or near, the filtration system. The use of union (O-ring seal) connections is highly recommended for ease of installation and future servicing.
IMPORTANT
Commonwealth of Massachusetts Plumbing Code 248 CMR shall be adhered to. The use of saddle valves are not permitted, please consult your local plumber.
Ensure that the line voltage corresponds to the stated voltage on the units specification label. Make sure that the plug on the power cord from the system and the outlet match. For proper operation, and to ensure the highest quality water from the system, make sure that the system is not connected to a switched electrical outlet.
CAUTION
This equipment is to be installed to comply with the basic plumbing code of the Building Officials and Code Administrators, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
CAUTION
Water pressure must not exceed 100 psig (690 kPa). To reduce water pressure, install a water pressure regulator and set water pressure to suit application. Note that the trans membrane pres­sure must not exceed 45 psi (310 kPa).
10
P/N 1011055 Rev. F 12/13
Page 11
UFL-420/440 WATER FILTRATION SYSTEM
INSTALLATION (continued)
Mounting the System
The UFL system comes with a Mounting Bracket to mount the system securely. When mounting the system, pay attention to the following guidelines:
Note the location of the water supply, drain, and an appropriate electrical outlet when choosing a mounting location.
Allow sufficient access for cartridge replacement. The UFL-420 system should be mounted with 20 inches below the unit to allow proper access when changing cartridges. The UFL-440 system should be mounted with 40 inches below the unit.
Mount the system near but NOT above an appropri­ate electrical outlet.
Do NOT mount the system above any electrical equipment or items that may be damaged if they get wet.
Mount the system near a drain for flushing opera­tions.
Mount the system before all consumable water filtration processes.
Secure the Mounting Brackets into wall studs or with the appropriate heavy duty mounting hardware.
The system is pre-assembled to Mounting Brackets. The Mounting Brackets have mounting holes secure the bottom of the system to the wall.
Inlet Water Plumbing
The Inlet water plumbing line should be 1” NPT or larger. A shutoff valve (not supplied) should be installed in the line leading to the system. The valve should be mounted close to the system inlet and sized properly for the inlet plumbing line.
An optional “T” or Cross Fitting with cap or plug can be installed between the Inlet Valve and the System Inlet. This fitting can be used for draining and sanitizing the system and downstream plumbing.
The system should only be connected to the cold water line.
Before connecting the fitting to the System Inlet, the plumbing to the system must be flushed clear of all debris. Hold a bucket at the inlet water line and slowly open the Inlet Water Valve. Allow the pipe to flush until all debris is removed.
INSET
Water Flow
Into Filter Base
Flow Control
see inset)
Flow Controller
(supplied,
Sanitation
Plug (not
supplied)
Inlet Water
Valve (not
supplied)
P/N 1011055 Rev. F 12/13
11
Filter Base
Inlet Drain Valve (not
Supplied)
Figure 3. Inlet Water Plumbing
Incoming
Water
Supply
Page 12
UFL-420/440 WATER FILTRATION SYSTEM
INSTALLATION (continued)
Permeate Line Plumbing
To ensure the highest quality and safest water, it is recommended that a check valve (to prevent backflow) be installed in the water line after the permeate connec­tion. This will help prevent possible contamination of the filter system due to other equipment downstream. The check valve (not supplied) should be mounted close to the system outlet, and sized properly for the plumbing line. Check with local codes for the proper specification.
A shutoff valve (not supplied) should be installed in the filtered water line leading from the system. The valve should be mounted close to the system outlet and sized properly for the plumbing line. This valve will allow for easier servicing and future cartridge replacement.
Drain Valve Connection
The drain hose is for flushing particle buildup out of the system during self cleaning.
1. Cut a length of the provided 20-foot coil of braided tubing so it reaches the drain from the Drain Valve.
2. Connect one end of the hose to the Drain Valve and secure it with a provided Worm Clamp (Figure
4).
3. Direct the other end of the hose to the drain.
When connecting the drain hose, pay attention to the following guidelines:
Secure End
Drain
Drain Line from System
Secure End
Floor Drain
Figure 4. Proper Drain Plumbing
Drain Line from System
2” (5.1 cm) minimum
Standpipe
2” (5.1 cm)
minimum
• The drain line plumbing must be able support the flow rate whenever the system flushes. This flow rate is dependent on the inlet water pressure, inlet pipe size, and system.
• The drain line leading out of the system must be as short as possible and slope downwards without any kinks or loops.
• The drain line plumbing must be position and secured at least 2 inches above the drain (Figure
4). This air gap protects the system from contami­nation in the event of a backed-up drain.
• The drain used must not be blocked or restricted.
• The drain used must be as large or larger than the drain line plumbing.
12
P/N 1011055 Rev. F 12/13
Page 13
UFL-420/440 WATER FILTRATION SYSTEM
INSTALLATION (continued)
Starting the Controller
1. Select the proper AC plug for your electrical outlet and install it onto the power supply.
2. Plug the appropriate end of the power cord into the controller.
3. Plug the other end of the power cord into the elec­trical outlet. The LEDs on the controller will light up.
4. The controller automatically enters Flush Mode and the Flush LED starts to flash.
5. When flushing is complete, the Flush LED will stop flashing and one or more LEDs will remain lit, indicating the unit has power and which interval is selected in the controller.
Rinsing the Ultra Filter Cartridge
The Ultra Filter Cartridge must be rinsed before the sys­tem is used to remove any air and protective solution.
NOTE: Ultra Filter Cartridge must be rinsed to drain before use. Rinsing to drain removes storage solu­tion and air. Do NOT rinse into carbon if present. Carbon life and/or performance may be affected.
1. Direct water from the Permeate Outlet to a drain.
2. Open the tap or faucet closest downstream to the filter system.
3. Slowly open the inlet water valve and allow water to enter the system.
4. Press the FLUSH button. The Drain Valve will open and air and water will come out of the drain line. Repeat six times to ensure all air and stor­age solution are flushed out of the Ultra Filter Cartridge.
5. Allow water to continue to run through the system and out the faucet for 15 minutes.
6. Inspect the unit for any leaks and repair as needed.
7. After 15 minutes with water flow, close the tap or faucet and let the system stand without water flow for 15 minutes to allow trapped air to come out of the hollow fibers of the Ultra Filter Cartridge.
8. After 15 minutes without water flow, open the tap or faucet for five minutes to flush out the trapped air.
9. Close the tap or faucet.
10. Press the FLUSH button to open the Drain Valve. Repeat six times to ensure any remaining air is flushed out of the system.
P/N 1011055 Rev. F 12/13
13
Page 14
UFL-420/440 WATER FILTRATION SYSTEM
INSTALLATION (continued)
Sanitizing the System and Lines
The plumbing must be sanitized to eliminate possible contamination that may have occurred during the instal­lation process.
One ounce (30 ml) of liquid chlorine bleach (regular bleach, unscented 5.25 % - 6 % sodium hypochlo­rite) or Kay-5 sanitizer solution (Sodium Dichloro-s­Triazinetrione Dihydrate, 6%) or equivalent can be used to sanitize the plumbing.
The Kay-5 sanitizer solution is made by dissolving a 1 oz. packet of Kay-5 powder in 2 oz. (60 ml) of clean warm water. This can be done by removing 1 inch from the top of the Kay-5 packet and adding the 2 oz. of warm water to the packet. Mix with a coffee stirrer to dissolve. When added to the system, this will create a 60-100 ppm chlorine solution.
NOTE: Follow the handling and safety instructions supplied with the sanitizer.
1. Follow the steps in the Rinsing the Ultra Filter Cartridge in the Installation section of this manu-
al.
2. Turn off the water to the system.
IMPORTANT
Commonwealth of Massachusetts Plumbing Code 248 CMR shall be adhered to. The use of saddle valves are not permitted, please consult your local plumber.
CAUTION
Ingesting the protective solution may cause irrita­tion of the gastrointestinal tract, colic, diarrhea, or other similar symptoms
9. Immediately close the tap and let the system stand with no water flow for at least 15 minutes to allow the sanitizer to sanitize the pipes.
10. After 15 minutes without water flow, open the tap and flush until the presence of sanitizer is gone. All other taps should be opened to flush any bleach from the plumbing. Close the taps.
11. Press the FLUSH button to complete the flushing process.
3. Open the faucet or tap closest downstream to the system.
4. Close the Inlet Water Valve and allow the system to depressurize.
5. Place a bucket under the “T” or cross fitting at the inlet connection to the system. Open the inlet drain valve or unscrew the cap to drain the sys­tem.
6. Press the FLUSH button to help drain the system.
7. When the water flow out of the inlet fitting stops, close the inlet drain valve and pour the liquid bleach into the inlet connection fitting. Be careful not to spill sanitizer onto clothing or skin. You may want to add the sanitizer using a cup. Reattach the cap on the fitting.
8. Slowly open the inlet water valve and allow water to flow out of the tap until the smell of sanitizer is present.
14
P/N 1011055 Rev. F 12/13
Page 15
UFL-420/440 WATER FILTRATION SYSTEM
MAINTENANCE
Replacing the Ultra Filter Cartridge
1. Turn off water to the system by closing the inlet valve.
2. Press the FLUSH button to flush the system and relieve pressure. Repeat several times.
3. Place a bucket under the “T” or cross fitting at the inlet connection to the system. Open the valve or unscrew the cap to drain the system.
NOTE: Make sure there is enough room next to the system to remove the cartridge.
4. Close the inlet drain valve or reattach the cap on the “T” fitting when the water flow stops.
5. Unplug the system.
6. Remove the Snap Ring from the Ultra Filter Housing. Grab the raised lug with a pair of pliers and pull towards the center of the End Cap and away. The Snap Ring should lift out of its groove.
7. Remove the End Cap, End Cap O-ring, and Cartridge from the housing (Figure 5).
Ultra Filter
Cartridge
Cartridge
O-Ring
End Cap
O-Rings
NOTE: If the Cartridge does not easily come out of the Housing, remove the opposite End Cap for assistance.
8. Inspect the Large End Cap O-rings and End Cap O-ring for nicks or cuts. Replace as needed.
9. Lubricate all O-rings with a food-grade silicone lubricant. Apply a light coating of lubricant to the inside center tube at both ends of the new car­tridge.
10. Record the serial number of the new cartridge. The cartridge serial number is engraved on one end of the outer tube (for example: 05K 12013).
11. Install the End Cap O-ring on the End Cap and insert the Large End Cap into the end of the new cartridge.
12. Position the new cartridge and End Cap at the housing and gently insert into the housing.
13. Press the End Cap into position until it is fully seated and the Snap Ring groove is visible.
14. Install the Snap Ring by guiding the non-lugged end into the groove first, pushing outward and working around the ring until it snaps into place.
End Cap
Snap Ring
Figure 5. Replacing the Ultra Filter Cartridge
NOTE: Make sure that the Snap Ring is fully seated before turning the water on.
15. Rinse the new Ultra Filter Cartridge before placing the system back into operation. Follow the Rinsing the Ultra Filter Cartridge and Sanitizing the System and Lines procedures in the Installation section of this manual to complete the cartridge change.
16. When rinsing is complete, repressurize the system.
System Sanitization
The system and downstream plumbing should be sani­tized at least every six months. When necessary, follow the procedure in Sanitizing the System and Lines in the Installation section of this manual.
P/N 1011055 Rev. F 12/13
15
Page 16
UFL-420/440 WATER FILTRATION SYSTEM
MAINTENANCE (continued)
Changing the Interval Setting
CAUTION
Changing the flush interval can cause the Ultra Filter to plug prematurely and may reduce the life of the filter. Consult the factory for more informa­tion.
Though not recommended, the Interval Setting on the controller can be changed. If the setting must be changed, use the chart below. Press and hold the cor­responding button. After 5 seconds, the Button LED will turn on. After 10 seconds, the Flush LED will also turn on.
Flush
Interval
15 minutes A 10 seconds On On
30 minutes B 10 seconds On On
45 minutes C 10 seconds On On
1 hour A 5 seconds On Off
4 hour B 5 seconds On Off
6 hours C 5 seconds On Off
12 hours D 5 seconds On Off
24 hours D 10 seconds On On
Button Hold Time
Button
LED
Flush
LED
Resetting the Timer Program
During the normal operation, the system will flush according to the set interval. It is possible the system will flush at a time of high water use. If this poses a problem, the controller can be reset. Unplug the power supply, wait for 5 seconds, and then plug the power supply in. When power is restored to the controller, it will automatically enter Flush Mode. The controller will then begin timing from the point when power is restored based on the interval setting selected.
Figure 6. Controller
16
P/N 1011055 Rev. F 12/13
Page 17
UFL-420/440 WATER FILTRATION SYSTEM
TROUBLESHOOTING
Problem Possible Cause Corrective Action
Unit does not have power. The power cord is not correctly
plugged in.
The Control Display is blank. The power cord is not correctly
plugged in.
Control Board is inoperable. Contact your maintenance person or
Transformer is inoperable.
No water comes out of the fil­ter system
Low water flow/pressure out of system
Water tastes bad. Storage/shipping solution not com-
Flush runs continuously. Drain Valve stuck open. Replace/rebuild the Drain Valve.
Flush occurs at time of high water usage.
Water splashes at drain dur­ing flush.
Water leaks at the ends of the Filter Cartridge after changing cartridges.
Water leaks from Permeate port.
Water leaks from system fit­ting or connection.
Inlet Valve closed Open the Inlet Valve
Inlet Strainer is plugged Clean/replace Inlet Strainer
End of the capillaries plugged Clean/replace Filter Cartridge
See above. See above.
The system may be in a flush cycle. Wait for the flush cycle to end.
Flushing program not set correctly for water conditions.
Drain Valve is stuck open. Replace/rebuild the Drain Valve.
The inlet water pressure is too low. Boost the inlet water pressure/replace
pletely rinsed out of system.
Biological growth in pipes. Sanitize plumbing.
Water conditions changed. Consider installing taste and odor filtration.
Broken capillary in Filter Cartridge. Replace Filter Cartridge.
Controller sending continuous signal to valve.
The Flush Interval is set to interfere with water use.
Drain line not positioned properly. Reposition the end of the drain line.
Cartridge end connections are not tight enough.
O-rings not lubricated. Lubricate O-rings with food-grade lubricant.
O-rings are split, cut, or twisted Replace O-rings.
Permeate port is not tight enough Tighten, with wrench if necessary.
O-ring not lubricated. Lubricate O-ring with food-grade lubricant.
O-ring split, cut, or twisted. Replace O-ring.
Fitting broken or loose. Retighten or replace the fitting.
Not enough pipe thread sealant used.
Plug power cord in correctly.
Plug power cord in correctly.
Authorized Service agency.
Decrease the flush interval (refer to the Operation section of this manual).
pipes.
Rinse system for a longer period of time.
Replace the controller.
Change Flush Interval. Unplug unit and plug in at a time of lower water usage.
Tighten with wrench if necessary.
Redo the fitting with the proper amount of sealant.
P/N 1011055 Rev. F 12/13
17
Page 18
UFL-420/440 WATER FILTRATION SYSTEM
REPLACEMENT PARTS
Replacement Parts can be purchased from an authorized dealer. Contact
A.J. Antunes & Co. at 1-630-754-1000 or toll free in the United States at 1-800-253-2991.
1
2
8
3
4
13
5
11
6
7
9
10
6
5
4
12
14
2
15
3
16
18
P/N 1011055 Rev. F 12/13
Page 19
UFL-420/440 WATER FILTRATION SYSTEM
REPLACEMENT PARTS (continued)
Replacement Parts can be purchased from an authorized dealer. Contact
A.J. Antunes & Co. at 1-630-754-1000 or toll free in the United States at 1-800-253-2991.
Item Part Description Qty. No.
1 2190150 Union Adaptor, 1” NPT 1 2 2190147 Nipple, Hex 1” NPT 2 3 2180181 Ring, Lock 2 4 2180228 Cap, End 1” Port 2 5 7000413 O-Ring Replacement Kit 1 0200235 O-Ring, End Cap 2 0200236 O-Ring, Cartridge 4 2140153 Lubricant, High Vacuum Grease 1 6 0504065 Clamp, 4” Filter 1 7 3080157 Screw, Tap 8-32 x 3/8” Lg. 4 8 7000411 Cartridge Replacement Kit UFL-420 1 (Includes O-Ring Replacement Kit) 7000412 Cartridge Replacement Kit UFL-440 1 (Includes O-Ring Replacement Kit)
Item Part Description Qty. No.
9 2180201 Filter Housing, UFL-420 1 2180202 Filter Housing, UFL-440 1 10 0021667 Flow Reg. Assy., UFL-420, 7.9 gpm 1 0021666 Flow Reg. Assy., UFL-440, 15 gpm 1 11 2070117 Nipple, 3/4” NPT 1 12 4040189 Solenoid Valve, NC 3/4” NPT 1 13 0504279 Bracket, Mounting 1 14 0012357 Universal Pulse Controller 1 15 0012146 Power Adapter Assembly 1 16 2190148 Plug, Pipe 1” NPT 1 17* 2140158 Cord, Loctite Thread Sealing 1 18* 0700769 Wire Harness 1
*not shown
P/N 1011055 Rev. F 12/13
19
Page 20
LIMITED WARRANTY
Equipment manufactured by A.J. Antunes & Co. has been constructed of the finest materials avail­able and manufactured to high quality standards. These units are warranted to be free from defects in materials and workmanship for a period of one year from date of purchase under normal use and service, and when installed in accordance with manufacturer’s recommendations*. The ultra filtration membrane cartridge is warranted under the same terms and conditions on a prorated basis for 24 months from date of purchase.
*To ensure continued proper operation of the units, follow the maintenance procedure outlined in the Owner’s Manual.
1. This warranty does not cover failures due to improper system installation, defects caused by improper storage or handling prior to placing of the equipment into service. This warranty does not include overtime charges or work done by unauthorized service agencies or personnel. This warranty does not cover normal maintenance, calibration, or regular adjustments as specified in operating and main­tenance instructions of this manual, and/or labor involved in moving adjacent objects to gain access to the Equipment.
2. A.J. Antunes & Co. reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations. Changes to update equipment do not constitute a warranty charge.
3.
If shipment is damaged in transit, the purchaser should make a claim directly upon the carrier. Careful inspection should be made of the shipment as soon as it arrives and visible damage should be noted upon the carrier’s documentation. Damage should be reported to the carrier. This damage is not covered under this warranty.
4. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, EACH OF WHICH IS HEREBY EXPRESSLY DISCLAIMED. THE REM­EDIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN NO EVENT SHALL A.J. ANTUNES & CO. BE LIABLE FOR SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR THE BREACH OR DELAY IN PERFORMANCE OF THIS WARRANTY.
Prices and specifications are subject to change without notice.
Loading...