AirStage ASHE12GACH, ASHA12GACH, ASYA12GACH, ASHA09GACH, ASYA09GACH Operating Manual

...
PART NO. 9377772183
ASYE07GACH / ASHE07GACH ASYE09GACH / ASHE09GACH ASYE12GACH / ASHE12GACH ASYE14GACH / ASHE14GACH
ASYA07GACH / ASHA07GACH ASYA09GACH / ASHA09GACH ASYA12GACH / ASHA12GACH ASYA14GACH / ASHA14GACH
EnglishDeutschFrançaisEspañolItalianoΕλληνικάPortuguêsРусскийTürkçe
OPERATING MANUAL
INDOOR UNIT (Wall mounted type)
Keep this manual for future reference.
UNITÉ INTÉRIEURE (Type montage mural)
Conservez ce manuel pour pour toute référence ultérieure.
MANUAL DE FUNCIONAMIENTO
UNIDAD INTERIOR (Tipo montado en pared)
Conserve este manual para posibles consultas futuras.
MANUAL DE FUNCIONAMENTO
UNIDADE INTERIOR (Tipo mural)
Guarde este manual para consulta futura.
BEDIENUNGSANLEITUNG
INNENGERÄT (wandmontierter Typ)
Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf.
MANUALE DI ISTRUZIONI
UNITÀ INTERNA (tipo montato a parete)
Conservare questo manuale per consultazione futura.
ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ (Επιτοιχιος τύπος)
Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
ВНУТРЕННИЙ МОДУЛЬ (настенного типа)
Сохраните данное руководство для последующего использования.
KULLANIM KILAVUZU
İÇ ÜNİTE (Duvara monteli tip)
Bu kılavuzu ileride başvurmak üzere saklayın.
[Original instructions]
Refer to the rating label with the serial number.
MADE IN P.R.C.
En-1
● Check the condition of the installation stand for damage.
● Operate only with air fi lters installed.
● Do not drink the water drained from the air conditioner.
● Do not apply any heavy pressure to radiator fi ns.
● Do not use infl ammable gases near the air conditioner.
● Do not touch the piping during operation.
● Ensure that any electronic equipment is at least 1 m away from either the indoor or outdoor units.
● This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of ex­perience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Note: Switching the operating mode in the heat recovery system may require some time to prepare for operation. Please note that this is not a fault.
PRECAUTIONS ON INSTALLATION
CAUTION
● Do not attempt to install this air conditioner by yourself.
● This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs.
● When moving, consult authorized service personnel for disconnection and installation of the unit.
● The unit must be grounded.
● Make sure drain work is implemented properly for drainage.
● Avoid installing the air conditioner near a fi replace or other heating apparatus.
● When installing the indoor and outdoor unit, take precautions to pre- vent access to infants.
NAME OF PARTS
(3)(1)
(13)
(12)
(11)(10)(9)
(4) (5) (6) (7)
(2)
(8)
(1)
(3)
(8)
(1) Operating Control Panel (2) MANUAL AUTO button: This is used to operate it while remote
controller is not available. (3) Indicator Lamps (4) OPERATION Indicator Lamp (green): It lights on while operating. (5) TIMER Indicator Lamp (orange): It lights on while timer is working. (6) Remote Control Signal Receiver: This is the place to receive the
signals from the remote controller. (7) FILTER Indicator Lamp (red): It lights on if the fi lter became dirty.
Clean the fi lter referring to "CLEANING AND CARE". It lights off
when RESET button is pressed after cleaning. (8) Intake Grille (9) Air Filter
SAFETY PRECAUTIONS
● Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
● The instructions in this section all relate to safety; be sure to maintain save operating conditions.
● “WARNING” and “CAUTION” have the following meanings in these instructions:
WARNING
This mark indicates procedures which, if im­properly performed, might lead to the death or serious injury of the user.
CAUTION
This mark indicates procedures which, if im­properly performed, might possibly result in per­sonal harm to the user, or damage to property.
PRECAUTIONS ON USE
WARNING
● Do not keep exposing oneself to the direct wind of air conditioner for a long time.
● Do not insert fi ngers or objects into the outlet port or intake grilles.
● Except for EMERGENCY, never turn off main as well as sub breaker of the indoor units during operation. It will cause compressor failure as well as water leakage. First, stop the indoor unit by operating the control unit, converter or external input device and then cut the breaker. Make sure to operate through the control unit, converter or external input device.
● If the power supply cord of this appliance is damaged, it should only be replaced by the authorized service personal, since special purpose tools and specifi ed cord are required.
● If any refrigerant happens to leak, extinguish any fl ames, ventilate the room and get in touch with authorized service personnel.
CAUTION
● Provide occasional ventilation during use.
● Do not use in applications involving the storage of foods, precision equipment, or art works.
● Do not place animals or plants in the direct path of the airfl ow.
● Do not direct airfl ow at fi replaces or heating apparatus.
● Do not block or cover the inlet port and outlet port.
● Do not climb on, or place objects on, the air conditioner.
● Do not set fl ower vases or water containers on top of air conditioners.
● Do not hang objects from the indoor unit.
● Do not place anything below the indoor unit that should not get wet.
● Always turn off the electrical breaker whenever cleaning the air condi- tioner or the air fi lter.
● Do not pour water or cleaning solvent on the unit directly, or wash the unit with them.
● Do not expose the air conditioner directly to water.
● Do not operate the air conditioner with wet hands.
OPERATING MANUAL
PART NO. 9377772183 VRF system indoor unit (Wall mounted type)
CONTENTS
SAFETY PRECAUTIONS ....................................................................... 1
NAME OF PARTS .................................................................................. 1
MANUAL AUTO OPERATION ............................................................... 2
ADJUSTING THE DIRECTION OF AIR CIRCULATION ........................ 2
OPERATING TIPS ................................................................................. 2
CLEANING AND CARE.......................................................................... 3
TROUBLESHOOTING ........................................................................... 3
SPECIFICATIONS .................................................................................. 4
Loading...
+ 4 hidden pages