
Airpura Limited Warranty
5 years on parts and 10 years labor
See www.airpura.com for details
To close the filter chamber
Operating
& Filter Replacement
Directions
V600
Thank You for choosing an
Airpura High Efficiency Air Purifier
To bring you the benefits of clean indoor air
To Begin Using Your Airpura...
Inspect the exterior of your Airpura to verify there is no
damage from shipping. If any damage is noted please
follow the instructions in the Airpura returns policy.
Wipe the unit with a damp cloth to remove any dust from
packaging
Replace the
gasket
Position the
indentation
in the cover
into the center of
the HEPA filter
Replace the
4 screws and
tighten
Turn the
Airpura
back onto
it's casters
Plug the unit into a regular grounded 110 volt outlet
Turn on the unit to MAX and allow it to run for a few minutes
Set the variable speed control to the level you wish
The most efficient way to use your Airpura for regular air
quality maintenance is to run it at a low speed 24 hours a
day 7 days a week
Feel the difference breathing clean air makes
to your health

Filter Maintenance and Replacement
The Pre-Filter
Can be vacuumed from the exterior of the unit
once a month or more often.
Should be replaced at least after 12 months of use
To vacuum the pre-filter
Use the brush attachment on your vacuum cleaner
Vacuum slowly around the mesh surface of the filter chamber
The Activated Carbon Filter
Position the pre-filter
inside the filter chamber
Place a felt gasket
at the bottom of the
filter chamber
Unfold the filter slider
(Supplied with replacement
filters or on request
Part#6F 001)
Roll it into a spiral
Should be changed as needed in heavy applications and
at least every 24 months in normal use.
The HEPA Filter
Should be replaced at least every 3 to 5 years of normal
use
To open the filter chamber
Turn over
the Airpura
Remove the
4 retaining
screws
Take off
the cover
Remove the
gasket
Insert the tube into
the filter chamber
inside the pre-filter
Let the canister
slidedown the
filter slider
Let the spiral open
to fill the opening
Pull the filter slider up
out of the cavity using
both hands and let the
canister slide to the
bottom of the cavity
Open the top of
the spiral to make
a slight funnel
Remove the filter
slider and fold it
for further use
Insert the carbon
canister into the
funnel and hold it
straight
Slide in the
Hepa filter
See over for
closing the
filter chamber