Air-O-Swiss S450 Quick Setup Manual

Page 1
PLEASE READ FIRST
DO NOT DISCARD! Save for future reference.
Please read the manual or check our website www.airoswiss.net for further information.
QUICK SET UP GUIDE S450
QUICK OPERATION DESCRIPTION S450
4
Remove the accessories from inside the unit.
5
Remove the top cover of the unit and take the water tank from the unit by using the tank handle.
10
Caution: Hot steam and
boiling water! Do not allow the appliance to be used by children. Steam and boiling water can lead to burns.
Carefully remove the unit from its box.
2
Use the appliance only on a flat and stable surface that is heat and water resistant. Keep a minimum distance of 4ft from walls, furniture, and curtains.
8
Remove the unit from the plastic wrapping. Note: the top cover of the unit is loose.
3
Always plug the power cord into the appliance first, before connecting it to the electrical outlet. A sound from the unit indicates that the appliance is supplied with power.
9
Open the carton box carefully and remove all styrofoam parts from the packaging.
1
Close the tank cap securely, place the tank into the unit and put the cover back on.
76
Insert the Anti-Mineral-Pad into the steam tray. Turn the water tank upside down, unscrew the cap and fill with water.
ECON
AUTO
H M L
L
M
H
AUTO ECON
CURRENT
DESIRED
I
J K
L
A) Switch on/off
B) AUTO- / ECON-Mode
C) Setting humidity level
D) Manual operation
E) Timer
F) Cleaning symbol (also see section about Decalcification-Mode)
G) Output level symbol
H) Current and desired relative humidity symbol
I) Automatic shut-off «Water Tank empty»
J) AUTO-Mode symbol
K) ECON-Mode symbol
L) Timer symbol
Page 2
RECOMMENDED TO CLEAN WITH EZCal AND EZCAL PRO
TROUBLESHOOTING
Switch off the appliance and unplug it from the socket before cleaning the unit. Clean the water tank and the base regularly. Use water only, no detergents.
For best results, use EZCal and EZCal Pro cleaning agents to remove deposits from the humidifier base.
FURTHER INFORMATION
DO NOT DISCARD! Save for future reference.
Please read the manual or check our website www.airoswiss.net for further information.
There is a sample of EZCal included in the packaging of your humidifier!
Only use 1 packet for 32oz of water. Do not change the ratio. Thoroughly rinse the base with tap water and make sure no EZCal residue remains in the base. Instructions for use are on the packet. Please note: EZCal and EZCal Pro are the only recommended cleaning and descaling solution. Do NOT use any other cleaning solutions since it can damage the product. Any use of cleaning solutions apart from EZCal and EZCal Pro will void the warranty.
EZCal and EZCal Pro descaling agents are available at selected retail stores and online at www.airoswiss.net.
What is EZCal and EZCal Pro?
EZCal and EZCal Pro are cleaning and descaling agents recommended for all humidifiers. The decalcification ingre­dients cleans the mineral build-up in the humidifier base.
Humidity level is not changing or does not reach the desired humidity level
• If the water tank needs refilling more than once per day, the unit is working properly and the climatic condition in the room has an influence on the humidity.
Reasons for low humidity level:
• air circulation is very high (air is fully exchanged several times per day – the humidifier needs to starts its work from scratch)
• insulation of home (see air circulation)
• open space with high ceilings (not only the footage of the room counts but also the height) – high-rise buildings require more humidification.
• open windows – works similar to air circulation (if it is very cold outside don’t open the window more than 2 times per day for 3 minutes)
• big difference between outside temperature and inside temperature – the colder the air the less moisture it is capable of holding. The more the air is heated up the lower the percentage of relative humidity (= the amount of water vapor in the air, compared to the amount the air could hold if it was totally saturated)
• position of the unit – if it is placed close to a door, window or air vent. This increases the air circulation.
Unit is not working
• If the unit is not working and the empty light is not flashing you might have set the desired humidity too low and the current humidity level in the room is higher. That is why the unit switches off automatically.
• Start the decalcification mode as described in manual page 12.
Unit is not running
Insert the plug fully into the unit! A sound from the unit indicates that the appliance is supplied with power.
Symbol E2 appears
When the display shows «E2», the current relative humi­dity has reached 90%. For safety reasons, the appliance switches off automatically. The appliance switches back on, when the relative humidity falls below 85%.
Do not submerge the base in water! Thoroughly rinse the base with tap water and make sure no EZCal or EZCal Pro residue remains in the base!