In accordance with 2004/108/EC Directive and 1999/5 EC-R & TTE Directive
Claus
■ EN 55022:2006 Class BLimits and methods of measurement of radio disturbanc
Description
characteristics of information technology equipme
■ EN 61000-3-2:2000+Disturbances in supply systems caused by household appliance
A2:2005 Class Aand similar electrical equipment "Harmonics
■ EN 61000-3-3:1995+Disturbances in supply systems caused by household appliance
A1:2001+A2:2005and similar electrical equipment "Voltage fluctuations
■ EN 55024:1998+A1:2001Information Technology equipment-Immunity characteristics-Limi
+A2:2003And methods of measuremen
■ AS/NZS CISPR22:2006Electromagnetic compatibility-requirements for radio disturbanc
Class Bcharacteristics of information technology equipmen
■ CE markin
Manufacturer/Importe
Signature :
Name :Albert Ye
Position/ Title:Vice President (Stamp)Date: 2008/10/1
AirLive POE-100CAM CE Declaration Statement
Country Declaration Country Declaration
cs
Česky [Czech]
da
Dansk [Danish]
de
Deutsch
[German]
et
Eesti [Estonian]
en
English
es
Español
[Spanish]
el
Ελληνική [Greek]
fr
Français [French]
it
Italiano [Italian]
lv
Latviski [Latvian]
sv
Svenska
[Swedish]
OvisLink Corp. tímto prohlašuje, že tento AirLive
POE-100CAM je ve shodě se základními
požadavky a dalšími příslušnými ustanoveními
směrnice 1999/5/ES.
Undertegnede OvisLink Corp. erklærer herved, at
følgende udstyr AirLive POE-100CAM overholder
de væsentlige krav og øvrige relevante krav i
direktiv 1999/5/EF.
Hiermit erklärt OvisLink Corp., dass sich das
Gerät AirLive POE-100CAM in Übereinstimmung
mit den grundlegenden Anforderungen und den
übrigen einschlägigen Bestimmungen der
Richtlinie 1999/5/EG befindet.
Käesolevaga kinnitab OvisLink Corp. seadme
AirLive POE-100CAM vastavust direktiivi
1999/5/EÜ põhinõuetele ja nimetatud direktiivist
tulenevatele teistele asjakohastele sätetele.
Hereby, OvisLink Corp., declares that this AirLive
POE-100CAM is in compliance with the essential
requirements and other relevant provisions of
Directive 1999/5/EC.
Por medio de la presente OvisLink Corp. declara
que el AirLive POE-100CAM cumple con los
requisitos esenciales y cualesquiera otras
disposiciones aplicables o exigibles de la
Directiva 1999/5/CE.
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ OvisLink Corp. ΔΗΛΩΝΕΙ
ΟΤΙ AirLive POE-100CAM ΣΥΜΜΟΡΦΩΝΕΤΑΙ
ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ
ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ
1999/5/ΕΚ.
Par la présente OvisLink Corp. déclare que
l'appareil AirLive POE-100CAM est conforme aux
exigences essentielles et aux autres dispositions
pertinentes de la directive 1999/5/CE
Con la presente OvisLink Corp. dichiara che
questo AirLive POE-100CAM è conforme ai
requisiti essenziali ed alle altre disposizioni
pertinenti stabilite dalla direttiva 1999/5/CE.
Ar šo OvisLink Corp. deklarē, ka AirLive
POE-100CAM atbilst Direktīvas 1999/5/EK
būtiskajām prasībām un citiem ar to saistītajiem
noteikumiem.
Härmed intygar OvisLink Corp. att denna AirLive
POE-100CAM står I överensstämmelse med de
väsentliga egenskapskrav och övriga relevanta
bestämmelser som framgår av direktiv
1999/5/EG.
lt
Lietuvių
[Lithuanian]
nl
Nederlands [Dutch
mt
Malti [Maltese]
hu
Magyar
[Hungarian]
pl
Polski [Polish]
pt
Português
[Portuguese]
sl
Slovensko
[Slovenian]
sk
Slovensky [Slovak]
fi
Suomi [Finnish]
Íslenska [Icelandic]
no
Norsk [Norwegian]
Šiuo OvisLink Corp. deklaruoja, kad šis AirLive
POE-100CAM atitinka esminius reikalavimus ir kitas
1999/5/EB Direktyvos nuostatas.
Hierbij verklaart OvisLink Corp. dat het toestel AirLive
POE-100CAM in overeenstemming is met de
essentiële eisen en de andere relevante bepalingen
van richtlijn 1999/5/EG.
Hawnhekk, OvisLink Corp, jiddikjara li dan AirLive
POE-100CAM jikkonforma mal-ħtiġijiet essenzjali u
ma provvedimenti oħrajn relevanti li hemm
fid-Dirrettiva 1999/5/EC.
Az OvisLink Corporation kijelenti, hogy az AirLive
POE-100CAM megfelel az 1999/05/CE irányelv
alapvető követelményeinek és egyéb vonatkozó
rendelkezéseinek.
Niniejszym OvisLink Corp oświadcza, że AirLive
POE-100CAM jest zgodny z zasadniczymi wymogami
oraz pozostałymi stosownymi postanowieniami
Dyrektywy 1999/5/EC.
OvisLink Corp declara que este AirLive
POE-100CAM está conforme com os requisitos
essenciais e outras disposições da Directiva
1999/5/CE.
OvisLink Corp izjavlja, da je ta AirLive POE-100CAM
v skladu z bistvenimi zahtevami in ostalimi
relevantnimi določili direktive 1999/5/ES.
OvisLink Corp týmto vyhlasuje, že AirLive
POE-100CAM spĺňa základné požiadavky a všetky
príslušné ustanovenia Smernice 1999/5/ES.
OvisLink Corp vakuuttaa täten että AirLive
POE-100CAM tyyppinen laite on direktiivin 1999/5/EY
oleellisten vaatimusten ja sitä koskevien direktiivin
muiden ehtojen mukainen
Hér með lýsir OvisLink Corp yfir því að AirLive
POE-100CAM er í samræmi við grunnkröfur og aðrar
kröfur, sem gerðar eru í tilskipun 1999/5/EC.
OvisLink Corp erklærer herved at utstyret AirLive
POE-100CAM er i samsvar med de grunnleggende
krav og øvrige relevante krav i direktiv 1999/5/EF.
A copy of the full CE report can be obtained from the following address:
OvisLink Corp.
5F, No.6 Lane 130,
Min-Chuan Rd, Hsin-Tien City,
Taipei, Taiwan, R.O.C.
This equipment may be used in AT, BE, CY, CZ, DK, EE, FI, FR, DE, GR, HU, IE, IT, LV, LT, LU, MT, NL, PL, PT, SK,
SI, ES, SE, GB, IS, LI, NO, CH, BG, RO, TR
This Air Live product has been designed with safety in mind. However, if not used properly electrical
products can cause fires which may lead to serious body injury. To avoid such accidents, be sure to
heed the following.
Legal Caution
Video and audio surveillance can be forbidden by laws that vary from country to country. Check the
laws in your local region before using this product for surveillance purposes.
Heed the safety precautions
Be sure to follow the general safety precautions and the “Operation Notice.”
In case of a breakdown
In case of system breakdown, discontinue use and contact your authorized Air Live dealer.
In case of abnormal operation
• If the unit emits smoke or an unusual smell,
• If water or other foreign objects enter the cabinet, or
• If you drop the unit or damage the cabinet:
1 Disconnect the cable and the connecting cables.
2 Contact your authorized Air Live dealer or the store where you purchased the product.
Operation Notice - Operating or storage location
Avoid operating or storing the camera in the following locations:
• Extremely hot or cold places (Operating temperature: 0 °C to +50 °C [32 °F to 122°F])
• Exposed to direct sunlight for a long time, or close to heating equipment (e.g., near heaters)
• Close to sources of strong magnetism
• Close to sources of powerful electromagnetic radiation, such as radios or TV transmitters
• Locations subject to strong vibration or shock
Ventilation
To prevent heat buildup, do not block air circulation around the device.
Transportation
When transporting the camera, repack it as originally packed at the factory or in materials of equal
quality.
Cleaning
• Use a soft, dry cloth to clean the external surfaces of the device. Stubborn stains can be removed
using a soft cloth dampened with a small quantity of detergent solution, then wipe dry.
• Do not use volatile solvents such as alcohol, benzene or thinners as they may damage the surface.
APPENDIX A – FRAME RATE & BIT RATE TABLE ....................................38
APPENDIX B – STORAGE REQUIREMENT TABLE....................................42
AirLive POE-100CAM User’s Manual
CHAPTER 1. INSTALLATION
1.1 Installation Steps
Follow these steps to install the Air Live POE100CAM on your Ethernet:
1. Check the package contents against the list below.
2. Set the device. See IP Installer User Manual on the available methods.
1.2 Package Contents
Item Description
IP Camera Air Live POE-100CAM IP Camera
Power Adapter Country-specific
CD User Manual / IP Installer and Document
Lens Camera Lens
Camera Stand Supplied with mounting screw
Printed Document Quick Installation Guide
1.3 Overview
Body:
Rear Panel:
Fixed Iris Lens
Audio In
Audio Out
Body
Power In
Reset
Note: Press the Reset Button to reboot the camera. Hold the Reset Button for 10 seconds to restore
the camera to default.
AirLive POE-100CAM User’s Manual 1
Network
Chapter 2. Using IP Camera via Mobile Phone
To use IP cameras via mobile phones, please make sure your RTSP is set to “ON”. (Default is “ON”) To
change the settings of IP cameras, please see “Settings” for details.
2.1 3G Mobile Phone viewing
For 3G mobile phone viewing, type “rtsp://<IP>:<PORT>/video.3gp” into your 3G web browser. <IP> is the IP
address of your IP camera, <PORT> is the RTSP port of your IP camera (Default value is 8554.)
Example: rtsp://100.10.10.1:8554/video.3gp
Note:
• You can also use RTSP clients (RealPlayer, MPlayer, Windows Media Player, Quicktime…etc.) to view RTSP
streaming, just type in “rtsp://<IP>:<PORT>/video.3gp” as the Player’s URL
2.2 2.5G Mobile Phone viewing
For 2.5G mobile phone viewing, type “<IP>/mobile.wml” into your 2.5G web browser. <IP> is the IP address of
your IP camera.
2 AirLive POE-100CAM User’s Manual
Chapter 3. Using IP Camera via Web Browser
3.1 System Requirement
To use the product normally, we strongly recommend your computer follows our minimum system requirement
(Computer level lower than this might cause some problems)
Item Requirements
CPU Pentium 4 1600MHz (or equivalent AMD)
Graphic Card 64MB RAM graphic cards (or equivalent on-board graphic cards)
RAM 512MB
Operating System Windows 98, ME (Please see Note)
Windows 2000, 2003, XP, Vista
Web Browser Internet Explorer 6 or later
Note:
• If you’re using Windows 98 or ME, please install IP Installer before using WEB UI to ensure the system runs
normally.
•If you can’t view the recorded video file (missing video decoder), please install Xvid codec while installing
Intelligent IP Installer. (For Windows 98, ME or 2000 server, the codec might not work properly. You’ll need to
download Xvid codec 1.0 from the internet.
AirLive POE-100CAM User’s Manual 3
Chapter 4. Initial accessing the IP camera
Camera installation
1. Insert CD into your PC/Laptop.
2. Auto Run Screen then shows up, click “Install Driver And Utility ” to install the configuration tool software
3. After complete installation, Run the configuration tool software
4. The Software scans the network and finds the IP Camera, then list in the dialog box.
5. If the Camera’s IP address is in the same IP segment as your LAN, select the founded IP Camera and click
“Link to IE” to proceed.
4 AirLive POE-100CAM User’s Manual
6. If the IP is not in your IP segment, select the founded IP Camera and click “Setup”
Note that the text color of the listed IP Camera is red if it is not in same the IP segment with your PC.
7. Follows setup instruction to change the IP address of the IP Camera.
Change IP Here
8. At the end of the setup instruction, the IP Camera Reboots
9. Click the Search button to search again
10. Click “Link to IE” to proceed.
AirLive POE-100CAM User’s Manual 5
11. The tool launch your Internet Explorer and prompts up the login dialog
12. Enter default user name and password: admin / airlive
13. After a successful login, the browser asks for ActiveX installation.
14. Install the ActiveX, and the browser shows the video stream.
Note:
If you need a public IP for your Router, please contact your ISP for the service.
1. Start your web browser, and enter the IP address or host name of the AIR LIVE IP camera in the Location / Address
field of your browser.
Note:
• If you only want to view the video without setting page, enter “http://<IP>/index2.htm” as your web URL.
2. Use the default account “admin” and default password “airlive”.
Note:
• The default user name “admin” and the password are set at the factory for the administrator. You can
change them in the Account Menu under Setting.
6 AirLive POE-100CAM User’s Manual
3. The monitor image will be displayed in your browser.
AirLive POE-100CAM User’s Manual 7
Chapter 5. Configuration of Main Menu
5.1 Setting
This function is only for the Administrator. Click this button to get into the Basic and Advance settings menu.
5.2 Client Setting
Mode: Click the pulldown box to choose between MPEG4 and MJPEG video compression mode.
Note:MJPEG streaming is unavailable if RTSP mode is ON.
View Size: Select the desired display image resolution to 640X480 or 320X240.
Protocol: Select the transferring protocol from TCP, UDP, HTTP and Multicast.
Video Buffer: Turn the Video Buffer function On/Off. The Video Buffer function makes the streaming more
smoothly in unsteady network environment, but might cause a little delay in live viewing.
5.3 Image Setup
You can use the tool bar to optimize video brightness, contrast, and saturation.
8 AirLive POE-100CAM User’s Manual
5.4 Live View
Snapshot:
You can capture a still image shot by the camera and save it in your computer.
1. Press , and a snapshot window will appear.
2. Click “Save” to save the picture in your computer.
3. Click “Close” to return to the view page.
Digital Zoom in / out the image via the monitor window
1. Click to display the digital zoom in window.
2. Pull the
on the above window.
3. You can use the left click of your mouse to move the to any where on the window.
to adjust the digital zoom range, and it will be showed
Audio buttons:
:Speakers turned on. :Speakers turned off.
:Microphone turned on. :Microphone turned off.
: Volume control bar.
Note:
•
It means the speakers of your computer are turned on to transmit the sounds from the connected IP
camera(s). Similarly,
your microphone.
means you can broadcast to the connected IP camera(s) via the Ethernet using
Video play buttons:
:Pause the current video :Play the video.
:Stop the current video. :Record the current video.
AirLive POE-100CAM User’s Manual 9
Chapter 6. Setting
6.1. Basic
Click the “Basic” folder to display the sub folders, including System, Camera, Network, and Security.
6.2 System
6.2.1 Information
The Information page provides you with product factory information, including Product name, Firmware version,
and Web version.
10 AirLive POE-100CAM User’s Manual