Air King BFQ50 User Manual

50 CFM/0.5 SONES @ 0.10" WG.
HVI CERTIFIED 120 Volts, 0.25 amps, 60 hz.
Grill
White, polymeric grill secured in place with torsion springs;
easily removed if necessary, dimensions - 10" x 10".
SPECIFICATIONS
BFQ50
EXHAUST FANS
• Blower Wheel
1
/
One piece polymeric wheel 5
8
" diameter, 2
• Motor
Heavy duty, permanently split capacitor, plug-in, 4 pole motor,
life time lubrication, thermally protected, suitable for continuous operation. Rated 120 volts, 60 hz., 0.25 amps.
3
/
8
" wide, with 48 fins.
Acceptable for use over tub or shower when
installed in a GFCI protected branch circuit.
• Unit Mounting
• Fan Housing
1
1
/
/
2
Flame retardant ABS, 0.110" thick, dimensions 8
" x 9
16
" x 4
• Duct Collar
Plastic collar for 4" duct connection, comes complete with built
in non-metallic back draft damper for quiet operation.
• Ventilating Area
For bathrooms up to 45 sq. ft. For other rooms up to 60 sq. ft.
PERFORMANCE
HVI Sones Fan Speed Power Static Pressure (inches of w.g.) @ .1 SP RPM Watts
0 0.05 0.1 0.125 0.15 0.2 0.25 0.3 Air Flow - CFM 56 53 50 48 47 42 37 29 0.5 1225 28
Rated for ceilings insulated to R-40. Designed to mount in
3
/
4
".
ceilings with at least 6" of clearance. The unit is mounted directly to the joist using a separate lock-in bracket (included with unit). The housing will mount through drywall thickness up to
3
/
4
", with a rough-in opening of 8
• Single Pack Shipping Info
Box Dim: 11" x 12" x 6" UPC: 0-8316225021-6 Shipping Weight: 5
1
/
4
lbs.
1
1
/
2
" x 9
/
16
".
PROJECT
LOCATION
CONTRACTOR
FAN MODEL NUMBER NUMBER W.C. & REMARKS
IN
CFM
RPM WATTS AMPS SONES QTY
CUS
ARCHITECT
ENGINEER
SUBMITTED BY DATE
OPTIONAL EQUIPMENT
U.S.: 820 Lincoln Drive
Canada: 110 Glidden Road Brampton, Ontario L6T 2J3 Tel: (905) 456-2033 Fax: (905) 456-1015
Updated 12-07Specifications subject to change without notice.