Air King B500, B300 User Manual

IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
Models B300, B500 Blower
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
WARNING:
SHOCK AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
1. Read all instructions before installing or using range hood.
2. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
4. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-related construction.
TO REDUCE THE RISK OF FIRE, ELECTRIC
5. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
6. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
7. Refer to the instructions included with the Range Hood Canopy for additional safety information.
111597002 Rev. A 9-07
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
1 of 12
INSTALLATION INSTRUCTIONS
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
WARNING: THIS BLOWER IS INTENDED FOR USE ONLY
IN AIR KING PROFESSIONAL SERIES RANGEHOOD CANOPIES MARKED SUITABLE FOR USE WITH THIS BLOWER. DO NOT TO INSTALL IN ANY OTHER APPLICATION.
SECTION 1
Preparing for installation
NOTE: Before installing blower, make sure range hood canopy is properly installed and securely in place. See “Range Hood Mounting Instructions”.
1. Unpack blower from the carton and confirm that all pieces are present. In addition to the blower you should have:
8 - 8-32 Screws 8 - Washers 1 - Fuse 1 - Wire Harness 1 - Capcitor Cover 3 - #6 Screws 1 - Instruction/Safety Sheet
Stud w/Hex Nuts
Screw Stud
Keyholes
Figure 2
2. Using 8 of the included 8-32 screws and washers, mount the blower in place and tighten all screws. Confirm that the blower is securely seated in place and there are no air gaps around the blower gasket.
3. Plug the 3 wire quick connect cord from the blower into the receptacle on the range hood canopy. Plug the 4 wire quick connect cord from the blower into the one end of the wiring harness then connect the other end of the wiring harness to the receptacle in the range hood canopy. These cords will only fit into the receptacles one way (Figure 3).
Receptacles
2. Position capacitor attached to motor over center mounting hole in face of blower and fasten in place using (1) # 6 screw. Position the capacitor cover over the capacitor and fasten in place using (2) # 6 screws (Figure 1).
Figure 1
3. The installation of the blower is slightly different from one canopy height to another. For 18" high canopies proceed to Section 2, for 10" high canopies proceed to Section 3.
Capacitor
SECTION 2
Installation into 18" High Canopy
1. Lift blower up into the hood canopy and slide the keyhole slots in the blower mounting flange over the two studs of the hood. Slide the blower into place and tighten the hex nuts on the mounting stud while lining up the 8 holes in the blower mounting flange to the 8 screw studs of the hood (Figure 2).
Wire
Harness
Figure 3
Blower
SECTION 3
Installation into 10" High Canopy
1. Remove the rear bottom plate of the hood canopy. It is secured in place with a screw and washer on either side (Figure 4).
Screw
Washer
Bottom Plate
Figure 4
2. Lift blower up into the hood canopy and slide the keyhole slots in the blower mounting flange over the two studs of the hood. Slide the blower into place and tighten the hex nuts on the mounting stud while lining up the 8 holes in the blower mounting flange to the 8 screw studs of the hood (Figure 2).
111597002 Rev. A 9-07
www.airkinglimited.com
2 of 12
Loading...
+ 2 hidden pages