Air King AKLC703, AKLC709, AKLC701, AKLC702 User Manual

IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
Models: AKLC701, AKLC702,
AKLC703, AKLC709
Exhaust Fan with Light
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
4. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities.
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. This unit must be grounded.
9. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: DO NOT INSTALL OVER A TUB OR MOUNT IN
A SHOWER STALL ENCLOSURE.
10. NEVER place a switch where it can be reached from a tub or shower.
WARNING: DO NOT USE IN KITCHENS
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
SAVE THESE INSTRUCTIONS
210572200 Rev. A 6-06
www.airkinglimited.com
1 of 12
INSTALLATION INSTRUCTIONS CAUTION:
SERVICE PANEL BEFORE STARTING INSTALLATION.
MAKE SURE POWER IS SWITCHED OFF AT
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have:
1 - Grill with Glass Light Lens 1 - Damper Assembly (attached) 2 - #8 Screws 2 - Lockwashers 4 - Mounting Rails 1 - Instruction/Safety Sheet
2. Choose the location for your fan. To ensure the best air and sound performance, it is recommended that the length of ducting and the number of elbows be kept to a minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise and airflow restrictions. This fan will require at least 6" of clearance in the ceiling or wall, and will mount through drywall up to 3/4" thick. The fan can be mounted directly to the joist using the mounting tabs on the sides of the housing or between 16" on center joists using the 4 provided mounting rails.
"
5/8
"
1/2
"
3/8
"
1/4
Figure 2
SECTION 3
Existing Construction
1a. Mounting Rail Installation: Set housing in position between
the joist and trace an outline onto the ceiling material (Figure
3). Set housing aside and cut opening, being careful not to cut or damage any electrical or other hidden utilities. Install the rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the rails to the joists with nails or screws (not provided) (Figure 1).
SECTION 2
New Construction
1. Mounting Rail Installation: Install the rails on the housing and position the housing next to the joist. Using the gauge on the fan’s housing, line up housing so that it will be flush with the finished ceiling. Secure the ends of the rails with screws or nails (not included) to the joists and slide the housing into the final position (Figure 1).
Housing
Joist
Figure 1
2. Mounting Tab Installation: Using the gauge on the fan’s housing, line up housing so that it will be flush with the finished ceiling. Position the fan so that the tabs rest flat against the joist and secure with four nails or screws (not provided) to ensure proper installation (Figure 2).
Hanger Bar
Figure 3
1b. Mounting Tab Installation: Position housing against the joist
and trace an outline of the housing onto the ceiling material (Figure 4). Set housing aside and cut opening, being careful not to cut or damage any electrical or other hidden utilities. Place housing next to the joist and insure that it is flush with the finished ceiling. Secure with four nails or screws (not provided) to ensure proper installation (Figure 2).
Figure 4
210572200 Rev. A 6-06 2 of 12
www.airkinglimited.com
SECTION 4
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL
AND NATIONAL BUILDING CODES.
Plug
1. Connect the ducting to the fan’s duct collar (Figure 5). Secure in place using tape or screw clamp. Always duct the fan to the outside through a wall or roof cap.
Figure 5
NOTE: If damper detaches from unit, reattach by snapping the collar back onto the unit. It is designed to only fit one way.
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
NOTE: This unit includes a side access panel for wiring that does
not require the removal of the fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove the blower assembly and internal wiring compartment. Both methods are equally effective.
1a. External Wire Compartment: Remove the wire compartment
cover screw and place cover in a secure place (Figure 6).
Screw
Figure 7
NOTE: If the fan motor plug is connected to the fan housing receptacle, unplug so the blower assembly can be completely removed.
Wire Compartment Cover
Screw
Figure 8
2a. Wiring Fan/Light Independently: Run wiring from an approved
wall switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and two hot (black lead connected to the switch). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle.
2b. From where you have access to inside the fan’s junction box,
connect the one white wire from the house to both the white wire from the fan’s light receptacle and the white wire from the fan’s exhaust receptacle. Connect the first black wire from the wall switch to the red wire from the fan’s light receptacle. Connect the second black wire from the house to the fan’s exhaust receptacle. Connect the ground wire from the house to the green wire from the fan’s grounding screw (Figure 9). Use approved methods for all connections.
Supply
Ground
from
house
Hot (Black)
White
Wire
Screw
Compartment Cover
Figure 6
1b. Internal Wire Compartment: Remove the screw holding the blower
assembly in place. Lift up on the assembly and tilt it at a 45° angle to remove from the housing (Figure 7). Remove the wire compartment cover screw and place the cover in a secure place (Figure 8)
210572200 Rev. A 6-06 3 of 12
.
www.airkinglimited.com
Figure 9
3a. Wiring Fan/Light together: Run wiring from an approved wall
switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and one hot (black lead connected to the switch). Secure the electrical wires to the housing w ith an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle.
3b. From where you have access to inside the fan’s junction box,
connect the one white wire from the house to both the white wire from the fan’s light receptacle and the white wire from the fan’s exhaust receptacle. Connect the black wire from
Hot (Red)
the wall switch to both the red wire from the fan’s light receptacle and the black wire from the fan’s exhaust receptacle. Connect the ground wire from the house to the green wire from the fan’s grounding screw (Figure 10). Use approved methods for all connections.
Lances
Supply
Ground
from
house
White
Hot (Black)
Figure 10
4. Carefully tuck wire back inside wire compartment and replace wire compartment cover securing with the screw that was removed earlier.
Hot (Red)
SECTION 6
Completing the Installation
1. If the fan’s blower assembly was removed during the wiring process, reinstall the blower by reversing the directions in
Step 1b
2. Insert the fan’s plug into the receptacle (Figure 7).
3. Remove glass light lens from grill by unscrewing knob at the top of lens (Figure 11).
in Section 5
Wiring
.
Grill
Figure 13
#8 Screws
CAUTION: FAILURE TO SECURE THE GRILL MAY RESULT
IN A RATTLING OR HUMMING NOISE.
6. Install 2 - 60 watt maximum, type A19 medium base incandescent bulbs (not included).
7. Reinstall the glass lens in place by sliding the hole in the lens onto the rod from the grill and securing in place with
step 3
the lens knob removed in
(Figure 14).
Grill
Rod
Glass Lens
Glass Lens
Figure 11
4. Plug cord from lamp holders into the appropriate receptacle (Figure 12).
Knob
Cord
Lamp
Figure 12
5. Line up slots in the grill with lances on inside of housing. Insert included #8 screws through grill slots and into housing lances. Tighten both screws until the grill fits snugly to the ceiling. DO NOT OVER TIGHTEN (Figure 13).
Holders
Hole
Knob
Figure 14
8. Restore power and test your installation.
SECTION 7
Use and Care
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE SERVICING THE UNIT.
1. Cleaning the Grill: Refer to instructions in Section 6
Completing the Installation
lens. Use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry all parts before reinstalling. Refer to instructions in Section 6
Installation
2. Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER.
, to reinstall grill and glass light lens.
CAUTION: ALLOW BULB TO COOL BEFORE REPLACING.
, to remove grill and glass light
Completing the
210572200 Rev. A 6-06 4 of 12
www.airkinglimited.com
Loading...
+ 8 hidden pages