IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
Model:
AKEDT2
Timer Control
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fi re,
electric shock and injury to person, including the following:
1. Read all instructions before installing or using switch.
2. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
3. Installation work and electrical wiring must be done by
qualifi ed person(s) in accordance with all applicable
codes and standards, including fi re-related construction.
4. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
5. This unit must be grounded.
6. NEVER place a switch where it can be reached from a
tub or shower.
SAVE THESE INSTRUCTIONS
000000000 New 9/08 1 of 2
www.airkinglimited.com
INSTALLATION
TIME SWITCH
WARNING:
INSTALLATION AND USE OF
THIS EQUIPMENT SHOULD BE IN ACCORDANCE WITH PROVISIONS OF THE U.S. NATIONAL ELECTRICAL CODE, APPLICABLE
LOCAL CODES, AND PERTINENT INDUSTRY
STANDARDS.
1. TURN POWER OFF at circuit breaker or fuse panel.
2. Remove wall plate and existing switch from the wall box
if one is presently installed.
3. Select white or ivory overlay matching decorator style
wall plate to be used. Peel protective backing, and apply
overlay to front, rectangular recess of time switch. Be
sure to align pushbutton and LED locations of overlay to
time switch.
4. Referring to Wiring Diagram, connect the wires from the
fan/light time switch to the wires in the wall box using
the wire nuts provided.
5. Carefully place wires and switch into wall box, and secure with two mounting screws provided.
120
VAC
MOUNTING SCREWS
GROUND
LINE
NEUTRAL
DECORATOR WALL PLATE
WALL PLATE SCREWS
GREEN
WIRE
BLACK
WIRE
WHITE
WIRE
BLUE
WIRE
RED
WIRE
OVERLAY
LIGHT
6. Install decorator style wall plate (not included).
7. Turn power ON at circuit breaker or fuse panel.
OPERATION
1. The “SWITCH LOCATOR” LED is intended to remain ON
to assist fi nding the switch in a darkened room.
2. Press the top “ON/OFF” switch once to turn the fan and
light ON.
3. Press the top “ON/OFF” switch again to turn the light
OFF. NOTE: the fan will remain ON for the selected time
delay (factory default setting is 20 minutes).
4. When the time delay is completed, the fan will automatically shut OFF.
5. Press the bottom “TIME DELAY SELECTION SWITCH”
to cycle the fan time delay to 20, 40, or 60 minutes. The
corresponding LEDs will light indicating the selected
time period. NOTE: both “TIME DELAY” LEDS indicate a
60 minute time period.
ON/OFF
SWITCH
(LED)
SWITCH
LOCATOR
TIME DELAY
SELECTION
SWITCH
(LEDS)
TIME DELAY
FOR FAN
AUTO-OFF
FAN
MOTOR
Fan
Light
20
Fan
60
Time
40
000000000 New 9/08 2 of 2