Air King AK5000, AK5500, AK7000 Troubleshooting Guide

FLOW-THROUGH
FURNACE HUMIDIFIER
Installation
Warranty
Maintenance
Troubleshooting Guide
2004/2005 PRODUCTION
1
9
2
8
MODEL 7000 EC
ITEM NUMBER
4
3
5
DESCRIPTION
*1
humidifier control
2 connection cable
4
5
6
7
8
9
air damper
collar
evaporator pad 18 gallon
water distribution tray
nozzle
out door air sensor 1/per 011199000
10
11
12
13
14
15
16
17
18
19
20
flex water tube 1/4"x24"
needle valve assembly
flow through cover 18 gallon
side flow through 18 gallon
brass compression nut
nylon ferrule
brass orifice 1/per 010927002
grommet
solenoid assembly
washer
21
22
23
brass insert
#10-32 plastic screw
7
6
19
18
21
22
16
15
QTY/UNIT
1/per
1/per
10
11
14
15
16
17
20
12
22
16
15
13
23
PART NUMBER
011198000
011175000
0112350001/perbase 18 gallon3
1/per
1/per
1/per
1/per
1/per
1/per120/24VAC transformer
1/per
1/per
1/per
1/per
3/per
2/per
1/per
1/per
2/per
01A170930
01A172107
011334000
010911002
011120001
010916001
010933002
0PB132055
011234000
011239000
010932000
010926001
910283003
010913105
010283004
0109370001/perinlet water filter
2/per
1/per
01A930041
019001067
* Specify brand
FLOW-THROUGH
FURNACE HUMIDIFIER
Installation Warranty Maintenance Troubleshooting Guide
MODEL AK5000 AK5500 & AK7000 SUPPLEMENTAL INSTRUCTION SHEET
WARNING: THIS UNIT IS INTENDED TO BE INSTALLED BY AN LICENCED HVAC PROFESSIONAL – FOR THIS
UNIT TO OPERATE PROPERLY THE SUPPLIED 24 VOLT TRANSFORMER MUST BE INTERLOCKED WITH THE
FURNACE HEATING CYCLE – THE 24 VOLT TRANSFORMER SHOULD BE ENERGIZED ONLY WHEN THE FURNACE
IS IN HEATING CYCLE. THIS UNIT WILL NOT OPERATE PROPERLY AND YOU RISK DAMAGE UNLESS YOU
PROPERLY INSTALL THE TRANSFORMER.
DO NOT ATTEMPT TO COMPLETE THIS INSTALLATION
UNLESS YOU ARE A LICENCED HVAC PROFESSIONAL.
TRANSFORMER - MODEL AK5000, AK5500, AK7000
Hazardous Voltage Can Cause Personal Injury Or Equipment Damage.
Disconnect Power Supply Before Installing or Servicing.
On Multispeed Blower Applications, Do Not Wire The High Voltage Side Of The Transformer To The Same Power
Source That Services The Furnace Blower Or The Transformer May Burn Out Prematurely.
Do Not Attempt to Install the transformer unless you are an HVAC professional.
The transformer supplied with the unit is different then indicated in the supplied Installation/operating instructions. You have been supplied with a Class 2 120Volt/24 VAC hard wire transformer. It is designed to be connected to the furnace through the furnace accessory terminals, the furnace heating relay, or interlocked with the furnace blower. Install the transformer on the outside of a grounded metal junction box using only a 7/8” knockout hole. Secure the transformer in place using the locking nut on the transformer mounting sleeve.
HUMIDISENSE HUMIDIFIER CYCLING CONTROL - MODEL AK5000, AK5500, AK7000
In the supplied installation/operating instructions reference is made to the electronic “Humidisense” humidifier cycling control, and indicating LED’s. Because models AK5000, AK5500, & AK7000 are contractor installed units, with the transformer interlocked with the furnace’s heating cycles the electronic controls and accompanying LED’s are not required or installed on the units. Your furnace humidifier will automatically cycle ON & OFF when your furnace cycles, no adjustments are required.
ELECTRONIC HUMIDISTAT CONTROL MANUAL AND AUTOMATIC OPERATION - MODEL AK7000
In the supplied Model 7000 installation/operating instructions & maintenance/warranty booklets reference is made to the electronic humidistat control with manual and automatic operation. This control is not supplied with the contractor model AK7000, in its place your unit has been provided with a standard mechanical humidistat design for either duct mount or wall mount installation. Refer to the provided humidistat installation sheet for installation instructions.
ELECTRICAL WIRING – MODEL AK5000, AK5500, & AK7000
Once the wiring is complete you should have all the components wired in series (a continuous loop) as shown in figure 1 below. To make the connection to the humidifier’s solenoid valve use ¼” insulated male terminals or cut the ¼” female terminals present on the solenoid valves wire then strip the wire ends – connect to the low voltage wire using approved electrical wire nuts.
06/07
PN 6785034
FEUILLE D’INSTRUCTION COMPLÉMENTAIRE, MODÈLES AK5000, AK5500 ET AK7000
MISE EN GARDE : CET APPAREIL EST CONÇU POUR ÊTRE INSTALLÉ PAR UN PROFESSIONNEL CVC
AUTORISÉ SOUS LICENCE – POUR QUE CET APPAREIL FONCTIONNE CONVENABLEMENT, LE TRANSFORMATEUR DE 24 VOLTS FOURNI DOIT ÊTRE INTERVERROUILLÉ AVEC LE CYCLE DE CHAUFFAGE DE LA FOURNAISE - LE TRANSFORMATEUR DE 24 VOLTS DEVRAIT ÊTRE MIS SOUS TENSION SEULEMENT
LORSQUE LA FOURNAISE SE TROUVE DANS LE CYCLE DE CHAUFFAGE. CET APPAREIL NE FONCTIONNERA
PAS CONVENABLEMENT OU VOUS RISQUEREZ DES DOMMAGES À MOINS QUE LE TRANSFORMATEUR N’AIT
ÉTÉ CONVENABLEMENT INSTALLÉ. N’ESSAYEZ PAS DE COMPLÉTER CETTE INSTALLATION À MOINS QUE
VOUS NE SOYEZ UN PROFESSIONNEL CVC AUTORISÉ SOUS LICENCE.
TRANSFORMATEUR – MODÈLES AK5000, AK5500 ET AK7000
La tension dangereuse peut causer des blessures ou des dommages à l’équipement.
Débranchez l’approvisionnement en courant avant de faire l’installation ou l’entretien.
Sur les applications de souffleur à vitesses multiples, ne raccordez pas le côté à haute tension du transformateur
à la même source de courant que celle qui dessert le souffleur de la fournaise, sinon le transformateur risque de se détériorer prématurément.
N’essayez pas d’installer le transformateur à moins que vous ne soyez un professionnel CVC.
Le transformateur fourni avec cet appareil est différent de celui indiqué dans les instructions fournies d’installation/fonctionnement. Vous avez reçu un transformateur à câblage direct classe 2 de 120 volts/24 VCA. Celui-ci est conçu pour être raccordé à la fournaise au moyen des bornes accessoires de fournaise, du relais de chauffage de fournaise, ou pour être interverrouillé au souffleur de fournaise. Installez le transformateur à l’extérieur d’une boîte de jonction en métal avec mise à la terre en utilisant seulement un trou à pastille défonçable de 7/8 po. Fixez le transformateur en place en utilisant l’écrou de blocage sur le manchon de montage du transformateur.
COMMANDE DE CYCLAGE D’HUMIDIFICATEUR HUMIDISENSE - MODÈLES AK5000, AK5500 ET AK7000
Dans les instructions d’installation/fonctionnement fournies, il est fait référence à une commande de cyclage d’humidificateur «Humidisense» électronique et aux DEL d’indication. Étant donné que les modèles AK5000, AK5500 et AK7000 sont des ensembles installés par l’entrepreneur, avec le transformateur interverrouillé aux cycles de chauffage de la fournaise, les commandes électroniques et les DEL les accompagnant ne sont pas nécessaires ni installés sur les ensembles. L’humidificateur de votre fournaise passera automatiquement au cycle de MARCHE ET D’ARRÊT durant les cycles de votre fournaise, aucun ajustement n’est nécessaire.
FONCTIONNEMENT MANUEL ET AUTOMATIQUE DE LA COMMANDE D’HUMIDISTAT ELECTRONIQUE – MODÈLE AK7000
Dans le modèle 7000 fourni, les instructions d’installation/fonctionnement et la référence aux livrets d’entretien/garantie sont faites à la commande d’humidistat électronique avec fonctionnement manuel et automatique. Cette commande n’est pas fournie avec le modèle AK7000 de l’entrepreneur, et à sa place votre système a reçu un concept d’humidistat mécanique standard pour installation à montage sur canalisation ou mural. Référez-vous à la feuille d’installation de l’humidistat pour les instructions d’installation.
CÂBLAGE ÉLECTRIQUE - MODÈLES AK5000, AK5500 ET AK7000
Une fois le câblage terminé, vous devriez avoir tous les éléments câblés en série (une boucle continue) comme illustré à la figure 1 ci-dessous. Pour effectuer la connexion à la soupape de solénoïde de l’humidificateur, utilisez les bornes mâles isolées de ¼ po ou découpez les bornes femelles de ¼ po présentes sur le fil des soupapes à solénoïde, puis dénudez les extrémités du fil – raccordez le fil à basse tension en utilisant les coinceurs à câbles électriques approuvés.
06/07