When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
WARNING:
SHOCK AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
1. Read all instructions before installing or using fan.
2. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
4. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-related construction.
CAUTION: THIS FAN MUST NOT BE USED IN POTENTIALLY
DANGEROUS LOCATIONS SUCH AS FLAMMABLE, EXPLOSIVE, CHEMICAL-LADEN OR WET ATMOSPHERES.
5. Make certain that the power source conforms to the electrical requirements of the fan.
TO REDUCE THE RISK OF FIRE, ELECTRIC
6. The fan must be hung with at least 10 feet of clearance from the floor to the blades.
7. Completely reassemble fan according to instructions before reconnecting to power supply.
WARNING: TO REDUCE THE RISK OF PERSONAL INJURY,
DO NOT BEND THE BLADE BRACKETS OR BLADES WHEN INSTALLING THE BLADES, BALANCING THE BLADES, OR CLEANING THE FAN. DO NOT INSERT FOREIGN OBLECTS IN BETWEEN THE ROTATING FAN BLADES.
8. This fan is not for use in wet or damp locations.
9. Do not use fan outdoors and never locate the fan where it may fall into a bathtub or other water container.
10. This unit must be grounded.
11. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
984856M1 Rev. A 9-06
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
1 of 4
INSTALLATION INSTRUCTIONS
CAUTION:
SERVICE PANEL BEFORE STARTING INSTALLATION.
MAKE SURE POWER IS SWITCHED OFF AT
SECTION 1
Installation Requirements
1. Electrical Requirements: This unit requires a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR PERSONAL INJURY, PROPERLY INSTALL TO AN OUTLET BOX MARKED “ACCEPTABLE FOR FAN SUPPORT”. USE SCREWS PROVIDED WITH OUTLET BOX. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.
CAUTION: IF BRACKET AND/OR ELECTRICAL BOX ARE
NOT SECURELY ATTACHED, THE FAN COULD WOBBLE.
SECTION 3
Mounting the Fan
2. Carefully lift the fan and hang on the J-Hook, ensuring that all wires are clear of the rubber roller (Figure 2).
Rubber Roller
Downrod
J-Hook Bracket
Upper Canopy
2. Electrical Box: This unit will fit any of the following electrical boxes: 4" octagon box, 3" octagon box, 1/2" deep ceiling pan, or a plaster ring with 3-1/2" mounting hole centers mounted on one of the above listed boxes. This fan will also install on a “Wiremold” No. 5738 fixture box. The electrical box must be securely anchored and capable of withstanding a load of at least 35 pounds.
CAUTION: IF ONE OF THE ABOVE ELECTRICAL BOXES IS
NOT PRESENT FOR PROPER INSTALLATION, CONTACT A LICENSED ELECTRICIAN.
SECTION 2
Preparing the Ceiling Fan
1. Unpack fan from the carton and confirm that all pieces are present. The following should be present:
1 - Motor assembly 1 - Package containing:
1 - Lower canopy 4 - Flat washers 1 - Upper canopy 2 - 8/32" screws 6 - Blade lock washers 2 - #8 lock washers 6 - Blade screws 2 - #10 lock washers
1 - Downrod assembly 3 - Wire nuts 1 - J-hook bracket 2 - Wood screws 1 - Instruction/Safety Sheet 3 - Blades
2. Install J-Hook Bracket to an electrical box marked “Acceptable For Fan Support” using the screws provided with the outlet box. Insert the screws through the slotted holes in the bracket and attach to the electrical box. Tighten both screws (Figure 1).
Electrical Box
Screw
Figure 1
J-Hook Bracket
Figure 2
NOTE: Wires omitted from figure for clarity
WARNING: FAILURE TO SEAT DOWNROD ASSEMBLY ON
J-HOOK BRACKET COULD CAUSE DAMAGE TO ELECTRICAL WIRES AND CAUSE FAN TO FALL.
CAUTION: DO NOT PINCH
WIRES BETWEEN THE J-HOOK AND DOWNROD ASSEMBLY.
2. Slide lower canopy down the downrod until it is snug against the motor housing. Tighten both set screws
(Figure 3).
NOTE: Wires omitted
from figure for clarity
Lower Canopy
Screw
SECTION 4
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
1. Make sure the electrical box is properly secured. Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and one hot (black lead connected to the switch).Connect the white wire from the fan to the white wire from the supply. Connect the black wire from the fan to the black (hot) wire from the wall switch. Connect the green or bare copper ground wire from the house to the green wire from the fan. Use approved methods for all connections and carefully push wires up into the outlet box (Figure 4).
Figure 3
984856M1 Rev. A 9-06
www.airkinglimited.com
2 of 4