Other Great Products ........................................................................................................ 8
Warranty .............................................................................................................. Last Page
If you have a respiratory condition, please contact your physician prior to use.
FCC Statement
Potential for Radio/Television interference
This device complies with Part 18 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.This product has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 18 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that the interference will not occur in a particular installation. If the product does cause harmful interference to
radio or television reception, which can be determined by turning the product on or o, the user is encouraged to
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the product and the receiver.
• Connect the product into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help
• Changes or modications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
SAFETY INSTRUCTIONS
Prior to using the appliance, read through the instructions for complete use and
keep in a safe place for later reference.
•
WARNING: DO NOT use outdoors. Only use as intended and described
in this manual.
•
WARNING: DO NOT expose or immerse the Base in water or other liquids.
• Before using the appliance, extend the cord and inspect for any signs of damage. WARNING: DO NOT use if cord has been damaged.
•
WARNING: Keep cord away from heated surfaces and out of the way,
where it cannot be stepped on or tripped over.
•
WARNING: This appliance has a polarized plug (one blade is wider than the other)
as a safety feature. If the plug does not t fully into the outlet, reverse the plug.
If it still doesn’t t, contact a qualied electrician. WARNING: DO NOT attempt
to defeat this safety feature.
•
WARNING: ALWAYS place humidier on an elevated rm, at, level surface
where it’s not easily knocked over. (e.g. on a table, chest, cabinet, etc.).
•
WARNING: DO NOT place the appliance directly on the oor, next to a heating
vent, under direct sunlight, high temperature areas, near computers or sensitive
electronic equipment.
•
WARNING: DO NOT place the appliance directly on wood furniture or other
surfaces which could get damaged by water.
•
WARNING: NEVER use in an environment where explosive gases are present.
•
WARNING: DO NOT use any attachments not provided with the unit.
•
WARNING: NEVER use the appliance after a malfunction, after it has been
dropped or damaged in any other way.
• Only operate when fully assembled.
• Keep out of reach of children. Close supervision is necessary when this
appliance is used by or near children, elderly or disabled persons.
•
WARNING: NEVER drop or insert any object into any opening.
•
WARNING: DO NOT block any air outlets or intakes.
•
WARNING: NEVER cover the appliance when it’s in operation.
•
WARNING: To unplug turn controls to the “OFF” position, then remove the plug
from the outlet. Ensure your hands are dry.
•
WARNING: ALWAYS unplug and EMPTY the Water Tank when not in use for a
long period of time.
•
WARNING: ALWAYS turn o or unplug before removing, lling or emptying
the Water Tank.
•
WARNING: DO NOT wash, adjust or move without rst unplugging the unit.
•
WARNING: DO NOT touch the water or any other part in the Base
during operation.
•
WARNING: NEVER operate WITHOUT water in the tank.
•
WARNING: DO NOT use hot water in the tank.
•
WARNING: ONLY use water in the tank, never use any additive such as
essential oils, eucalyptus, water conditioners, etc… in the water.
•
WARNING: DO NOT move appliance with water inside the tank. In this case
remove the Water Tank and empty the Water Reservoir prior to moving.
•
WARNING: DO NOT attempt to repair or adjust the unit. Servicing must be
performed by professional or qualied personnel.
•
WARNING: Discontinue use if unit makes loud noises or has a strange smell.
• Perform regular maintenance of the Ultrasonic Nebulizer.
•
WARNING: DO NOT direct the mist against a wall or other home appliance.
•
WARNING: DO NOT pour water into the Base through Air Outlet during
cleaning and lling.
•
WARNING: DO NOT rinse Base under faucet.
•
WARNING: DO NOT immerse the Base in water.
•
WARNING: NEVER scrape the Ultrasonic Nebulizer with a hard or sharp object.
1
No More Dry Air
Thank you for choosing the Air Innovations® – Clean Mist™ Ultrasonic Humidier and
congratulations on taking this important step in improving the quality of air in your home
or oce.
The Air Innovations® – Clean Mist™ Ultrasonic Humidier uses Ultrasonic Technology to
create humidity instantaneously, while working silently to erase the discomforts of dry air.
Unpacking
1
Open the box and remove
packaging material.
2
Carefully remove the humidier
from the box by pulling the Base
of the unit (Do not take the unit
out of the box by pulling the tank).
3
Remove the plastic bag
from the humidier.
*Follow directions to ll and operate the humidier.
Specications
Proudct Model Power Consumption Current Rating Voltage Tank Capacity Dimensions Weight
MH-40830W0.4A110-120V~60Hz4L / 1.1 Gallon8”W x 8”D
2
x 14.5” H
2.65 Lbs.
Parts & Contents
1
2
Rear View
8
3
5
4
6
7
10
15
14
13
9
11
12
1. Rotating Mist Nozzle
2. Lift Handle
3. Water Tank
4. Water Tank Window
5. Base
6. Humidity / Waterless Indicator
7. Power / Mist Control Knob
8. Air Outlet
9. Cleaning Brush
10. Water Reservoir
11. Ceramic Filter
12. Tank Cap
13. Ultrasonic Nebulizer
14. Water Sensor
15. Bottom Tank Handle
3
Filling The Water Tank
WARNING: Always unplug the unit before removing the Water Tank.
WARNING: DO NOT touch the water in the Base.
WARNING: NEVER ll the Water Tank from the top of the unit. Follow Water Tank
lling instructions in #4.
1
Remove Rotating Mist Nozzle
prior to lling the Water Tank.
4
Filling the Water Tank: Use clean,
cool, tap water. WARNING: DO
NOT
use extremely cold water, since
it may temporarily reduce the mist
output. WARNING:
with hot/warm water or use additives
as this could damage the unit and void
the warranty. WARNING:
have hard tap water STOP using tap water and use ONLY ltered, distilled,
cold boiled or bottled water.
NEVER ll
If you
2
Lift the Water Tank with both
hands using the Handle to remove
the humidier from the Base.
5
Replace the Tank Cap by rmly
turning clockwise until tight.
Turn the Water Tank upright and
check the Tank Cap for leaks.
If any water drips, remove the
Tank Cap and retighten.
WARNING: DO NOT place
Water Tank on the humidier
Base if the cap is leaking.
3
Turn the Water Tank upside down
and remove the Tank Cap
by turning it counter clockwise.
6
Lift the Water Tank with both
hands using the Handle and
replace on the humidier Base.
Make sure to follow the shape of
the Water Tank and the humidier
Base, so that the tank sits level
and ush to the Base. Ensure
the tank is rmly seated.
Attach the Rotating Mist Nozzle
to the top of the Water Tank by
snapping into place for desired
use as pictured.
7
4
Operating Instructions
WARNING: DO NOT operate the humidier without water in the tank.
WARNING: NEVER lift the tank o the Base while the unit is operating.
ON/OFF - Plug into a standard (120V AC) electrical
outlet. Turn the Mist Control Knob clockwise until
you hear a click and the “Humidity / Waterless”
Indicator turns green. To turn OFF, turn the Mist
Control Knob counterclockwise until you hear a
click and the indicator turns OFF. Mist may not
1
2
appear immediately; allow up to 15 minutes for the
water in the tank to transfer to the Base.
Mist Output – The unit will turn ON with the lowest
mist setting. Turn the Mist Control Knob clockwise
to increase the mist output and turn the Mist
Control Knob counterclockwise to decrease.
Rotating Mist Nozzle – Can be rotated 360° to
position mist direction to desired location. Simply
rotate nozzle with your nger when the mist nozzle
is in place.
3
Low Water – When the tank is out of water the
“Humidity / Waterless” Indicator will turn from green
to red and the automatic safety shut-o will turn the
Ultrasonic Nebulizer OFF. You may hear the fan for
a few seconds, this is normal.
4
5
Weekly Cleaning & Care
WARNING: Before cleaning always turn power o and unplug the unit from outlet.
WARNING: DO NOT rinse Base under faucet. To clean, wipe the Base with a paper towel.
WARNING: DO NOT use any solvents or aggressive cleaning agents. Keep water away
from the Air Outlet. WARNING: DO NOT tamper with the Water Sensor.
About White Dust -Use of high-mineral content water may cause a white mineral residue to
accumulate on room surfaces near the humidier. The mineral residue is commonly referred to as
“White Dust”. The higher the mineral content (the harder your water is), the greater the potential for
White Dust. The White Dust is not caused by a defect in the humidier, but is due only to minerals
suspended in the water from your tap. WARNING: If you have hard tap water STOP using tap water and use ONLY ltered, distilled, cold boiled or bottled water to minimize the White Dust
residue.
Tank Cleaning - Remove the Rotating Mist Nozzle from the top of the Water Tank then remove the
Water Tank from the unit. Turn the tank upside down, unscrew the Tank Cap and drain any water
from the tank. Wipe the tank with a soft damp cloth then
rinse it with warm water inside and out.
Base Cleaning - Gently wipe the Base with a
soft damp cloth.
White Dust Cleaning - If mineral deposits
“White Dust” are evident around the Ultrasonic
Nebulizer and Water Sensor, clean these surfaces
with a soft cloth and a small amount of undiluted
white vinegar. If necessary, mix a solution of 50%
white vinegar and 50% water and ll the Base with
enough solution to cover the Ultrasonic Nebulizer (a).
Allow it to soak for an hour and then use the provided
brush to gently loosen buildup on the
Ultrasonic Nebulizer (b). Put 1 cup of water in the
Base and wipe clean with a soft cloth.
WARNING: DO NOT rinse Base under faucet.
Ceramic Water Filter Cleaning - Remove the
Water Tank from the humidier Base. Remove the
Tank Cap (c) and rinse Ceramic Filter thoroughly with
tap water (d), then replace on Water Tank.
a
b
dc
Surface Cleaning - Clean all surfaces of the unit with a clean
damp soft cloth.
WARNING: When emptying the Water Reservoir on the Base, make
sure that the water is poured away from the Air Outlet (e). If water is
poured into the outlet it may damage the humidier.
Storage
1. Follow all cleaning instructions prior to storage.
2. Dry all parts, including the inside of the Water Tank.
WARNING: NEVER
3. Leave the Water Tank cap partially loosened to prolong the life of the cap.
4. Preferably store in its original box, in a dry place away from
high temperatures.
5. Follow all cleaning instructions after long periods of storage.
6
leave water inside the tank for several days.
e
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.