The Air+Health™ unit is designed to emit powerful ultraviolet light rays which sterilize and
reduce airborne microorganisms as they pass through a home’s heating or ai
conditioning system. It is installed in the main supply or return duct of the home’s system
and operates continuously to automatically purify the air in the home 24 hours a day.
This product is not sold as a medical device and is not for the purpose of diagnosis of any
disease or condition nor for use in the mitigation, treatment, or prevention of any disease or
condition.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY
BEFORE PROCEEDING WITH THE INSTALLATION
ITEMS INCLUDED IN KIT:
1-Air+Health™ Power Unit
1-Mounting Base
1-Ultraviolet Bulb
4-Sheet Metal Mounting Screws
1-Instruction Sheet
1-Fiberglass Duct Board Mounting Bracket
1-1-1/2” Hole Saw
1-Pair of Safety Glasses
(retain for future use
when maintaining
this product)
PRODUCT QUESTIONS…
CALL Home Health Products
for answers on product maintenance,
operation or replacement part questions.
!
Phone: (866)765-1587
FaxBack: (866)253-1029
"
$
E-mail:
sales@airhealth.com
English...................... Page 1
Français.................... Page 6
Español................Página 10
SAFETY CONSIDERATIONS
WARNING: Never expose eyes or skin to UVC light from any source.
• Looking directly at the UVC light may cause permanent eye damage or blindness.
• Never operate the Air+Health™ Air Purifying System out of the plenum.
• Designed for a closed duct system. Do not mount near a supply or a return air opening.
• All duct openings in direct line of site of the UV light must be sealed with aluminum tape or equivalent
sealing methods.
• Wear supplied safety glasses during installation. They will help block accidental UV exposure to eyes.
WARNING: UV light will break down plastic materials not rated for UV exposure:
(Examples: wire insulation, flex duct, drain pans and humidifiers)
• The unit must be mounted at least 30” from the above stated type of materials.
• If it is necessary to mount the unit in direct line of site of these types of materials, they must be shielded
with aluminum foil, aluminum foil tape, or sheet metal.
WARNING: DO NOT mount this unit outdoors.
• This product is designed for indoor installation only (i.e. Attics, crawl spaces, basements, etc.).
WARNING: Never touch broken bulb or internal contents of bulb. The bulb contains mercury.
• After opening the carton, unpack and inspect the unit and bulb for damage. Do not install this unit if any
damage is noticeable. If bulb is damaged, cracked or broken, do not touch bulb or other contents in carton.
Close carton and return to seller immediately.
• In case of accidental exposure to internal contents of bulb, wash hands and any other affected skin area
with mild detergent. Remove affected clothing immediately. If skin surface is pierced, seek medical
attention immediately.
NOTE: If you touch the glass of the bulb, you should wipe the glass clean with isopropyl alcohol and a lint free
wipe. If the bulb is not cleaned, the film of hand oils causes a reduction in the light intensity.
WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all
power OFF and have unit unplugged. Electrical shock can cause personal injury or death. Never expose eyes or
skin to direct UVC light from any source.
WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier.
WARNING: This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.). For
use on gas fired, oil fired, electric and split system heat pump forced air systems*. This product is NOT designed
to be mounted outside on gas fired or heat pump packaged units**.
*Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units.
**Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building
GENERAL INFORMATION
The Air+Health™ unit uses technology that is recommended by doctors who state that “ultraviolet radiation, properly
integrated with heating, ventilating, and air conditioning systems, shows the most promise as a widely applicable means
of air disinfection”.
1
Page 2
SIZING AND SELECTING UNITS
t
See chart below for determining your homes needs.
Square
Footage
Up to
2000
Air+Health™
(For ducts at
least 16” wide)
1 120 30 .5 60
Volts Watts Amps Hz
4000 2 120 30 .5 60
Notes:
• For homes with multiple systems, we recommend one unit per system.
• For homes with larger applications, multiple units are recommended.
Contact technical support at 1-866-765-1587 for sizing.
INSTALLATION
1. Locate a suitable location for the unit downstream from the ‘A’ coil
in the supply plenum or in the return plenum; preferably
downstream from the air filter. For optimum “cleaning” effect on
the ‘A’ coil, mount the unit in the supply plenum as close as
possible to the ‘A’ coil. (See Figure 1)
CAUTION: Investigate and determine the location of the A coil prior to
drilling holes in duct for mounting unit.
NOTE: For duct board installation, refer to enclosed bagged
assembly containing mounting plate and instructions.
2. Apply supplied mounting template to air duct in either a vertical or
horizontal position as shown in Figure 2. (Leave template
mounted to duct for future reference.)
3. Drill 1/8” diameter mounting holes at positions
indicated on template. (Refer to supplied template as
shown in Figure 3)
4. Cut out the large opening on the template using a drill
and the provided hole saw. (Refer to template as shown in Figure 3)
Provided
hole saw
Figure 1
5. Using a ¼” to ½” drill bit, drill view port hole as indicated on template. (Figure 3)
6. Mount the Air+Health™ mounting base onto the plenum with the supplied sheet metal screws. (Refer to template as
shown in Figure 3) This must be tight in order to activate the built in safety switch.
NOTE:DO NOT remove template from duct.
7. Install bulb into ballast. Do not handle the bulb with bare hands. Oils on the hands tend to shorten bulb intensity.
(See Figure 4)
Figure 2
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanen
eye damage or blindness. Never operate the Air+Health™ Air Purifying System out of the plenum. Avoid touching the
glass portion of the bulb with your hands.
Page 3
Figure 3
Figure 4
8. Wipe off the bulb glass with the supplied alcohol wipe. Then insert the bulb
t
through the center hole of the mounting base. (See Figure 5) The power cord
must be 90° to the view port hole on the mounting base.
9. With the ballast pressed against the mounting base, rotate the ballast clockwise
90°.
10. Plug the power supply cord into a standard electric wall outlet. Check bulb
operation by looking through the view port hole. NOTE: The view port hole is made of glass and will not allow any UVC rays to pass through. A blue glow
should be seen in the duct.
Figure 5
11. If blue glow is not seen, make sure base is
properly installed onto duct. There is a proving
switch located on the base that needs to be
seated properly onto the duct. Make sure that
when base is mounted that the plated
washer on the switch is raised
approximately 3/16” and the switch is fully
engaged. (See Figure 6)
12. With standard duct tape or like material, seal all
joints and seams of the plenum near the
mounting location to reduce any direct viewing
of light.
MAINTENANCE
WARNING: Unplug unit from outlet before
commencing inspection and cleaning.
NOTE: Wear disposable, non-absorbent
protective gloves prior to inspection
procedure in case of accidental breakage of
Figure 6
glass.
1. We recommend inspecting and cleaning bulb at least every 6 months depending upon your home environment and
condition of conventional filters and duration of use and their replacement cycle.
2. To maintain the bulbs maximum output intensity , replace your Air+Health™ Air Purifying System bulb annually,
depending upon your home environment using the replacement procedure below. The bulb should operate
continuously for maximum bulb life and light effectiveness.
REPLACEMENT PROCEDURE
WARNING: Unplug unit from wall outlet before starting replacement procedure.
NOTE: Wear disposable, non-absorbent protective gloves prior to replacement procedure
in case of accidental breakage of glass.
1. Rotate the Air+Health™ ballast assembly counter-clockwise until it stops. (See Figure 7)
2. Remove the ballast assembly and bulb from the mounting base. (See Figure 5)
3. Remove the bulb from the bulb socket. (See Figure 4)
4. Install replacement bulb into bulb socket. Do not handle the bulb with bare hands. Oils on the
hands tend to reduce bulb intensity.
5. Wipe off the glass with the supplied alcohol wipe.
6. Position the ballast assembly power cord 90° to the view port hole on the mounting base. (See
Figure 7)
7. Slide the bulb thought the hole in the mounting base. (See Figure 5)
8. Press the ballast against the mounting base and rotate the ballast assembly clockwise until it
stops. (See Figure 8)
9. After assembly is firmly in place, plug the power supply cord into a standard electrical wall outlet.
Check bulb operation by looking through the view port hole. A blue glow should be seen in the
duct.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanen
eye damage or blindness. Never operate the Air+Health™ Air Purifying System out of the plenum. Avoid touching the
glass portion of the bulb with your hands.
Page 4
Figure 7
Figure 8
10. After replacing lamp, make sure a new Lamp Replacement Label (supplied with lamp replacement) is applied to the
t
housing and dated with the date of installation.
NOTE: If blue light leaks through any portion of plenum and/or around mounting plate, unplug power supply cord
immediately and seal affected areas and/or rotate ballast and repeat step #8 above.
11. UV bulbs contain a small amount of mercury, like a typical fluorescent bulb. Check with your local waste
management authority for local disposal or recycling requirements. According to the EPA’s Universal Waste Rule,
these types of bulbs may be disposed of into household waste.
WARNING: Never touch broken bulb or internal contents of bulb. The bulb contains mercury.
NOTE: In case of accidental exposure to internal contents of bulb, wash hands and any other affected skin area
with mild detergent. Remove affected clothing immediately. If skin surface is pierced, seek medical attention
immediately.
TROUBLESHOOTING GUIDE
1. Pull back metal washer on mounting base. If lamp comes on, the base needs tightening to ensure that the safety
switch is fully engaged
2. If bulb does not light up, rotate ballast slightly clockwise or counter-clockwise
3. If bulb does not light up after rotating ballast, replace bulb.
4. If unit still does not light up after replacing bulb, replace ballast.
REPLACEMENT PARTS LIST
BULB
(Home Health Products Part
Number)
46444900
For replacement parts, contact Home Health Products at:
!Phone: 1-866-765-1587 • !Fax: 1-866-253-1029
$Email: sales@homehealthproducts.com
CLEAN-UP OF BROKEN BULBS
(see warnings on page two of this manual)
UV bulbs contain a small amount of mercury, like a typical fluorescent bulb. DO NOT touch any of the mercury with your
bare hands.
1. While wearing disposable, non-absorbent protective gloves, pick up the large pieces of glass with your hands.
2. Then, vacuum the entire area with a standard household vacuum cleaner ensuring the removal of all bulb material.
3. Dispose of the pieces of glass, the vacuum cleaner bag, and the disposable gloves in a sealed garbage bag.
4. Check with your local waste management authority for local disposal or recycling requirements. According to the
EPA’s Universal Waste Rule, these types of bulbs may be disposed of into household waste.
5. Wash hands and remove and wash clothes for added safety measures.
The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been investigated by UL.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanen
eye damage or blindness. Never operate the Air+Health™ Air Purifying System out of the plenum. Avoid touching the
glass portion of the bulb with your hands.
Page 5
3
Loading...