Copyright 2018 Airfree® Produtos Electrónicos S.A. All Rights Reserved.
No part of this publication may be reproduced, photocopied, transmitted, transcribed, stored
in a retrieval system, or translated into any language in any form or by any means without the
express prior written consent of Airfree® Produtos Electrónicos S.A.
Read operator’s manual before usage.
For indoor use only.
Double insulated electrical appliance.
When discarding this product, it must be sent to separate collection facilities for
recovery and recycling. By separating this product from other household-type waste,
the volume of waste sent to incinerators or land-fills will be reduced and natural
resources will thus be conserved.
Índice
Importante Instrucciones de Seguridad................................................................................ 11
Instalación y Conexión .......................................................................................................... 11
Lo que Airfree® Destruye ...................................................................................................... 12
Airfree® y Moho ..................................................................................................................... 12
Derechos de autor 2018 Airfree® Produtos Electrónicos S.A. Todos los derechos reservados.
Ninguna parte de esta publicación puede ser reproducida, fotocopiada, transmitida, transcrita,
almacenada en un sistema de recuperación ni traducida a cualquier idioma de cualquier
forma o por cualquier medio sin el consentimiento previo expreso por escrito de Airfree®
Produtos Electrónicos SA
Lea el manual del operador antes de su uso.
Solo para uso en interiores.
Aparato eléctrico con doble aislamiento.
Al desechar este producto, debe enviarse a instalaciones de recogida selectiva de
residuos para su recuperación y reciclaje. Mediante la separación de este producto
de otros residuos de tipo doméstico, se reducirá el volumen de residuos enviados a
incineradores o vertederos y, por tanto, se conservan los recursos naturales.
Index
Important Consignes de Sécurité.......................................................................................... 18
Installation et Branchement ...................................................................................................18
Ce que Airfree® Détruit .........................................................................................................19
Airfree® et Moisissure ............................................................................................................19
Copyright 2018 Airfree® Produtos Electrónicos S.A. Tous droits réservés.
Aucune partie de cette publication ne peut être reproduite, photocopiée, transmise, transcrite,
stockée dans un système de récupération ou traduite dans n’importe quelle langue, sous
quelque forme ou par quelque moyen que ce soit, sans l’autorisation expresse préalable
d’Airfree® Produtos Electrónicos S.A.
Lisez le manuel de l’opérateur avant utilisation.
Utilisation en intérieur uniquement.
Appareil électrique à double isolation.
Si vous devez jeter ce produit, il doit être envoyé aux installations de collecte pour
la récupération et le recyclage. En séparant ce produit des autres déchets de type
domestique, le volume de déchets envoyés aux incinérateurs ou décharges sera
réduit et les ressources naturelles seront ainsi conservées.
3
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS.
Airfree® is not intended for use by persons with reduced physical, sensory or mental
capabilities, or lack of experience or knowledge. Children should be supervised to
ensure that they do not play with the appliance.
Do not place your Airfree® in direct contact with water or liquids as it can cause an
electric and harmful shock hazard and damage to the unit itself.
Do not obstruct Airfree® air outlets with items such as towels, clothing, curtains, as it
will increase heating inside the ceramic core causing the device to shut off. If such
condition persists a general cut-off system will cut power supply requiring replacement
of the circuit board by an authorised dealer. This incident is not covered by the
Airfree® warranty.
Do not attempt to open Airfree® or touch its internal components. Do not insert any
objects as it may cause electric shock. Any attempt to open or tamper Airfree® will
void the warranty.
To clean Airfree®, unplug it from the electric outlet and use a dry cloth to wipe off its
surface. Do not attempt to open Airfree® to clean it inside which is not necessary.
Always keep Airfree® in its vertical position as shown in the picture, otherwise the unit
will be shut off until it goes back to the vertical position.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons or any authorised warranty service shop to avoid
potential hazard events. When returning your Airfree® for repair please make sure it is
well protected preferably inside its original box, to avoid additional damages.
Airfree® shall not be placed near flammable and toxic products.
SAVE THESE INSTRUCTIONS
Installing and Connecting
Plug the power cord into the nearest outlet. Make sure the surface is dry (never place
Airfree® on wet floor or immerge it in water). Make sure the On/Off led is on. After 30
minutes the top lid should be warm.*
Place Airfree® on a flat surface preferably not exceedingm 30’ / 75 cm from the floor,
not under furniture, shelves, or behind curtains as it will interfere with air flow and
Airfree® efficiency in destroying microorganisms.
Check if the area is compatible with the unit capacity to achieve best unit performance.
Using Airfree® in rooms larger than its capacity will greatly reduce its purifying
capacity.
44
Airfree® must be continuously on in the same room, 24 hours a day. Nevertheless,
temporarily removing it from the room will allow new microorganism contamination to
grow but it will be destroyed when Airfree® is plugged in again. The longer the period
without Airfree® the higher the new contamination in the room.
Airfree® is to be used preferably in rooms larger than 43 sq. ft. or 353 cu. ft. / 4 m² or
10 cm³.
Rooms with air condition or ventilation will not affect the air sterilization efficiency of
your Airfree®. Same for Heating systems.
Airfree® can be placed in corridors but the air sterilization effects will barely have any
effect in connecting rooms.
Avoid place the unit near open doors or windows to prevent some of the sterilized air
to exit the room.
SHORT POWER CORD INSTRUCTIONS
- A short power supply cord is provided to reduce the risk resulting from becoming
entangled in or tripping over a longer cord.
- Extension cords are available and may be used if care is exercised in their use.
- If an extension cord is used, the marked electrical rating of the extension cord
should be at least as great as electrical rating of the appliance, and the longer cord
should be arranged so that it will not drape over the counter or table top where it could
be pulled on by children or tripped over unintentionally.
POLARIZATION INSTRUCTIONS
This appliance has a polarized plug (one blade is wider than the brother). To reduce
the risk of electric shock, this plug will fit in a polarized outlet, reverse the plug. If it still
does not fit, contact a qualified electrician. Do not modify the plug in any way.
English
(*) The “Technical Characteristics“ describes which models incorporate the led light and
which models needs to be wall mounted.
What Airfree® Destroys
Mold and
Mildew
Viruses
Dust Mites
Allergens
Pet Dander
Allergens
Organic
Odors
Bacteria
Ozone (O3)
Pollens
Airfree® and Mold
It is important to stress that Airfree® will not destroy or remove mold from an infected
item or surface. Those surfaces must be cleaned manually since they are a continuous
source of new spores. Airfree® will destroy airbone molds, spores and prevents them from
contaminating other areas, inhibiting the growth of existing and new colonies.
55
T800
180 sq. ft. / 16 m²
42 W
120 V
1.5 lb / 0,7 kg
Totally Silent
Yes
White
Ø: 5,1 in / 13 cm
Height: 10.4 in / 30 cm
Technical Characteristics
Model
Capacity
Voltage
Electric Consumption
66
Noise
Weight
Color
Dimensions
Led light
How does Airfree® Work?
Cooling Chamber
Purified Air
Contaminated Air
Regardless of how hazardous a virus, fungus or bacteria might be they are fully destroyed by
the powerful heat inside the TSS™ ceramic core mini ducts. The heat inside the ceramic core
forces sterilized air up to the heat exchanger causing air convection, which generates negative
pressure underneath the ceramic core, so contaminated air is “sucked” in at Airfree® bottom
air inlets in a continuous, silent, and efficient air flow.
Cooled and clean air is delivered to the
environment without significant change
in room temperature and humidity.
TSS™ Sterilizing Ceramic Core
Inside the ceramic core 99.99% of all
microorganims are destroyed.
Air Inlets
Contaminated air enters
Airfree® by air convection.
English
1- Air oultlets
2- Side shell
3- On/Off led
4- Air inlets
5- Base
6- Power cord
7- Serial number
Airfree® Description
1
2
3
7
4
5
6
77
Frequently Asked Questions
1. Are there any side effects?
No. Airfree’s new technology uses heat to purify the air with meaningless heat contribution to
the room. No side effects, no emissions, NO IONS, nor new particles are generated. Airfree®
can be used in homes and offices, quietly, constantly, and efficiently purifying the air.
2. Can I install Airfree® in my walking closet ?
Yes if larger than 2x2 meters (43 sq. ft. or 353 cu. ft. / 4 m² or 10 m³). Otherwise it might warm
up the closet.
3. Can I use Airfree® in air conditioned rooms?
Yes.
4. How do I know if Airfree® is no longer working?
Check the top lid, if cold the sterilization system is not working. Please connect it to another
outlet and make sure the unit is in its vertical position for at least 1 minute.
5. Can I place Airfree® at the corridor to reach adjacent rooms?
No. Airfree® will just reduce air pollution in the corridor’s area.
6. Can I place Airfree® in a closed room?
Yes. Please remember such a room must have at least 43 sq. ft. (353 cu. ft.) / 4 m² (10 m³).
7. Should I turn off Airfree® when I leave house?
To achieve best performance we recommend to keep Airfree® always on. Turning the unit off
will stop the sterilization process allowing the room contamination to grow.
8. Can I change Airfree® from one room to another?
Airfree® must always be plugged in the same room 24 hours a day. Airfree’s patented
technology works gradually so, when removing it to another room the contamination in the
original room will start to increase.
9. Does CADR measure the effectiveness of the Airfree®?
Not at all. CADR is not designed to test the Airfree® technology. The AHAM seal
(usually found on the back of an air cleaner’s box) lists three Clean Air Delivery Rate
(CADR) numbers: one for tobacco smoke, one for pollen and one for dust. The CADR
indicates volume of filtered air delivered by an air cleaner. The reason why CADR is not
designed for Airfree® is because Airfree® does not filter but destroys microorganisms
instead, such reduction of bacteria, molds, viruses and other microorganisms can only be
measured after air sample incubation in a microbiology lab. Airfree® destroys (not trap or
attract to other surface) any microorganism regardless of how small they might be. 99.99% of
all microorganisms are fully destroyed when passing through the Airfree® patented ceramic
core.
10. What happens if Airfree® is disconnected or there was a black out?
Airfree® will take approximately the same time to recover the previous reduced contamination
level.
11. Does Airfree® eliminate bacteria and viruses?
Yes. Unlike the air filters in the market Airfree® is more efficient with the smallest
microorganisms as they are easily carried by Airfree’s airflow into the sterilizing TSS™ ceramic
core. Please check the independent bacteria and virus tests at our website.
12. How does Airfree® destroy dust mites?
Mold reduction in the environment causes reduction in the mold dependant dust mite
population. Airfree® also destroys the harmful toxins and fungus freed into the air by dust mite
feces and skeletons that trigger respiratory allergies and asthma.