For Part Numbers:
300-277 720-476 Airaid Oiled Media Filter 301-277 721-476 SynthaMax Dry Media Filter - Red 302-277 722-476 SynthaMax Dry Media Filter - Black 303-277 723-476 SynthaMax Dry Media Filter - Blue
2013-15 Dodge Ram 1500/2500/3500
Component Identification\
1. Airaid Premium Filter 1
2. Airaid Intake Tube 1
3. Cool Air Box 1
4. Reducer Coupler 1
5. Silicone Hump Hose 1
6. Filter Adapter 1
7. 1/2” x 22” Breather Hose 1
8. Weather Strip 32.5” 1
9. ¼-20 x 1/2” Button Head Screw 3
10. 1/4” Flat Washer 3
11. #52 Hose Clamp 1
12. #60 Hose Clamp 2
13. #64 Hose Clamp 1
14. 1/2" ID Grommet 1
15. 1/2” x Elbow 1
16. Male to Male Barbed Fitting 1
17. 1/4" NPT Barb Fitting 1
18. 1/2” - 3/4” Barbed Fitting 1
19. Adapter Gasket 1
Full color instructions can be viewed on our web site at Airaid.com. Use the Product Search function to find your part number, and click View Details.
Disconnect The Negative Battery Terminal.
1. Disconnect the air temperature sensor and loosen the
clamps on the intake tube. Remove the intake tube and set it aside.
4. Remove the two fender bolts in the air box cradle and remove the entire air box assembly. The bolts will be reused in step 10.
2. Lift the front of the engine cover up to unseat it from the mounting grommets and remove it.
X
5. Transfer the 4 factory air box grommets into the Airaid Cool Air Box as shown. Note: Two of the holes do not receive grommets.
X
2. Remove the PCV line connecting the air box to the valve cover. Note: The 90 degree fitting on the valve cov­er is to remain in place.
6. Transfer the air scoop from the factory airbox into the Airaid Cool Air Box as shown.
7. Prepare the Filter Adapter (#6) for installation by mat­ing it to the Adapter Gasket (#19) and aligning the bolt holes.
8. Mount the Filter Adapter and Gasket inside the Cool Air Box as shown using the three sets of 1/4-20 Button Head Screws (#9) and 1/4” Flat Washers (#10).
9. Install the 1/4” Barbed Fitting into the Cool Air Box snout as shown.
Page 2
1/2 to 3/4 Barbed Fitting
M to M Barbed Fitting
Elbow
10. Set the Airaid Cool Air Box into the cradle and se­cure it using the factory hardware removed in step 4.
13. Reinstall the engine cover.
11. Assemble the Airaid PCV line using the 22” Breather
Hose, 1/2” to 3/4” Barbed Fitting (#18) on one end. On the other end, connect the 1/2” Elbow to the Breather Hose using the Male to Male Barbed Fitting.(#16).
Hose Clamp #60
#60
#52
#64
14. Slide the Coupler, Hump Hose and Clamps onto the Airaid Intake Tube as shown. Do not tighten the Clamps at this time. Refer to the line drawing and packing list for detailed component identification.
12. Install the Elbow side of the Airaid PCV line onto the Barbed Fitting on the Cool Air Box and connect the other side to the factory valve cover elbow.
Grommet
15. Insert the 1/2” Grommet (#14) into the Airaid In­take Tube. Transfer the air temperature sensor from the factory intake tube, into the Airaid Tube. Hint: A small amount of silicone or soapy water makes for a safe Grommet/O-ring lubricant.
18. Double check your work!
Make sure there is no foreign material in the intake path. Make sure all clamps, hoses, bolts, and screws are tight. Double check the hood clearance!
Reconnect the negative battery cable!
16. Install the Intake Tube, Hump Hose side first, onto
the Cool Air Box, then onto the throttlebody. Align all four Clamps and tighten them. Reconnect the air temper­ature sensor.
Thank you for purchasing the Airaid Intake System. Contact Airaid @ (800) 498-6951 8:00 AM - 5:00 PM MST weekdays for questions regarding fit or instructions that are not clear to you. Your Airaid Intake System was carefully inspected and packaged. Check that no parts are missing, or were damaged during shipping. If any parts are missing, contact Airaid. The air filter element is protected from direct exposure to wa­ter and debris; care should be taken not to drive through deep water. WATER INGESTION IS THE DRIVERS RESPONSIBILITY! The air filter is reusable and should be cleaned periodically.
17. Install the Airaid Premium Filter onto the Filter Adapter inside the Cool Air Box. Install the Weatherstrip onto the Cool Air Box as shown, with the contour rolling away from the Filter.
FILTER IDENTIFICATION
720-476 Airaid Oiled Media 721-476 Airaid SynthaMax Dry Media - Red
722-476 Airaid SynthaMax Dry Media - Black 723-476 Airaid SynthaMax Dry Media - Blue
For your Oiled media filter we
suggest using the AIRAID Filter
Tune-Up Kit!
P/N 790-551 Aerosol Spray P/N 790-550 Squeeze Spray
Synthamax Air Filters do not require oil. Service air filter as needed by cleaning with common non-petroleum all-purpose household cleaner and water. Simple Green®, Formula 409® or equivalent works great. Apply cleaner to outside of air filter and allow to soak. Then flush filter clean from the inside out with a gar­den hose and repeat steps if necessary. Do not apply high pressure water or air to clean filter. Allow filter to air dry and reinstall.
Airaid Filter Co. 2688 E Rose Garden Ln. Phoenix AZ 85050 (800) 498-6951 AiraidInfo@airaid.com www.airaid.com
REV.01.13.15