Installation Instructions
For Part Numbers:
300-190 700-445 Airaid Oiled Media Filter
301-190 701-445 SynthaMax Dry Media Filter - Red
302-190 702-445 SynthaMax Dry Media Filter - Black
303-190 703-445 SynthaMax Dry Media Filter - Blue
2006-08 Dodge Ram 1500/2500/3500
5.7L V8
Component Identification
1. Airaid Premium Filter 1
2. Quick Fit Panel 1
3. Modular Intake Tube 1
4. Urethane Hump Hose 1
5. Reducing Coupler 1
6. Weather Strip 32 3/4” 1
7. Black Rubber Cap 1
8. #52 Hose Clamp 2
9. #60 Hose Clamp 2
10. #14 Speed Clamp 1
11. #24 Speed Clamp 1
12. Rubber Grommet 1
Full color instructions can be viewed on our web site at Airaid.com. Use the Product Search function to find your part number, and click View Details.
1. Disconnect the negative battery cable!
Loosen the hose clamp on the resonator. Dis-
2. Unlatch 4 clips on the factory airbox lid and
remove the lid and intake hose assembly. Re-
3. Squeeze the tab on the connector, and disconnect the intake temperature sensor.
4. Using a 10mm socket, remove two bolts
holding the intake resonator to the intake manifold. Lift and pull the resonator away from the
7. Install the supplied grommet (#12) into the
Modular Intake Tube (#3). Next, carefully slide
the factory temperature sensor into the grommet until it touches the tab on the temperature
5. Remove the factory seal from the throttle
body.
8. Install the Quick Fit Panel (#2) onto the factory
airbox base by sliding the tabs on the base thru
the Quick Fit Panel and then adjust the sides to
fit. Re-latch the 4 clips to hold the Quick Fit
6. Gently twist the air temperature sensor
counterclockwise and remove it from the
9. Install the urethane hump hose (#4) onto
the tube on the Quick Fit Panel using two
10. Install the reducing coupler (#5), small
end first, onto the throttle body using two #52
hose clamps (#8). Leave the clamps loose for
now.
11. Install the Modular Intake Tube (#3) into
the hump hose first and then into the reducing
coupler. Adjust for fit, and then tighten all 4
hose clamps.
12. Install the provided rubber cap (#7)
and speed clamp (#10) onto the nipple on
the Modular Intake Tube, as shown.

13. (Note: Because factory production toler-
ances vary, it may be necessary to remove the
tape on the wiring loom and pull out 1 1/2” of
wire to the temp sensor, and then re-install the
tape. Re-connect the wiring harness to the
temperature sensor.
14. Install the Airaid Premium Filter (#1) onto the
tube on the Quick Fit Panel and tighten the clamp.
Next install the weather strip (#6) on the top of the
Quick Fit Panel as shown. (Hint: Start at one end
of the Quick Fit Panel and work your way towards
the other end.)
15. Slip the #24 speed clamp (#11) over the
factory breather hose and re-connect the factory breather hose to the nipple on the Quick
Fit Panel . Squeeze the clamp to retain the
hose in place.
16. Double check your work!
Make sure there is no foreign material in the intake path. Make sure all clamps, hoses, fasteners, and wiring connections are tight.
17. Reconnect the negative battery cable!
Thank you for purchasing the Airaid Intake System. Contact Airaid @ (800) 498-6951 8:00 AM - 5:00 PM MST weekdays for questions regarding fit or instructions that are not clear to you. Your Airaid Intake System was carefully inspected and
packaged. Check that no parts are missing, or were damaged during shipping. If any parts are missing, contact Airaid. The air
filter element is protected from direct exposure to water and debris; care should be taken not to drive through deep water. WATER INGESTION IS THE DRIVERS RESPONSIBILTY! The air filter is reusable and should be cleaned periodically.
FILTER IDENTIFICATION
700-445 Airaid Oiled Media 701-445 Airaid SynthaMax Dry Media - Red
702-445 Airaid SynthaMax Dry Media - Black 703-445 Airaid SynthaMax Dry Media - Blue
For your Oiled media filter
we suggest using the AIRAID
Filter Tune-Up Kit!
Synthamax Air Filters do not require oil. Service air filter as needed by cleaning with common nonpetroleum all-purpose household
cleaner and water. Simple Green®,
Formula 409® or equivalent works
great. Apply cleaner to outside of
air filter and allow to soak. Then
flush filter clean from the inside out
with a garden hose and repeat steps
if necessary. Do not apply high
pressure water or air to clean filter.
Allow filter to air dry and reinstall.
P/N 790-551 Aerosol Spray
P/N 790-550 Squeeze Spray
Airaid Filter Co. 2688 E Rose Garden Ln. Phoenix AZ 85050 (800) 498-6951 AiraidInfo@airaid.com www.airaid.com
REV.11.4.13