AlPHONE
SPEAKER PHONE INTERCOM
C
CONTROLS & FUNCTIONS )
0 @ (D 0®®0®0(0) ® (g)(0)
MODELS; TS-6K(6way)
TS-12K(12 way)
INSTRUCTIONS -
(3^ Directory card
(0) Door release button
(1
f) Volume control
832809 TS-KI-0284®
Handset microphone
Handset
Handset speaker
Call button
Paging button
Station selector buttons
Privacy switch for loudspeaking
microphone
Loudspeaker
Terminal cord
Terminal box
Receiver cradle for wall mounting
Coil cord
Loudspeaking microphone
Case
C SPECIFICATIONS )
* Power source:
* Current consumption:
* Calling:
* Loudspeaking output:
* Paging:
* Desk paging:
* Wiring:
DC 12 volt. Use PS-12S (PS-12C in North America) AC adaptor.
150 mA maximum.
Push button station selection. A single stroke chime sounds when call button is depressed.
200 mW maximum.
Use PG-U paging adaptor in conjunction with Aiphone paging amplifier: PG-A or PG-B and
speakers (or with PG-3 and a 8 ohm horn speaker).
Use desk paging adaptor PG-K with PG-U and paging amplifier. Output is approx. 300 mW
per station.
Up to 24 conductors may be required. Please refer to wiring diagram showing system that
meets your requirements.
( FEATURES )
* Combination telephone and loudspeaking function. Either telephone conversation using handset at both stations or hands
free communication at receiving station is included.
* Up to 13 stations can be connected in a system.
* 1 channel common talk system. Conference calls can selectively include up to 13 stations.
* Paging system can be added using PG-U adaptor connected to Aiphone paging amplifier: PG-A or PG-B. Desk paging
(allows page message to be transmitted through loudspeaker at selected masters) is also available using PG-K adaptor.
* Designed for either desk use or wall mounting.
* Privacy switch for loudspeaking microphone prevents monitoring or eavesdropping by another master while in privacy
position.
* Volume controls for loudspeaker and tone call.
- 1
* Door opener button can be used for remote control of door release. Other remote functions such as switching on outside
lights etc., can be accomplished using a proper relay.
* Excellent voice fidelity.
* Door station IB-DA, etc. can be installed with adaptor DS-B. (Up to two door stations may be connected to up to 4
masters.)
* Block paging and talkback paging is available when using PA-B adaptor.
( INSTALLATION^
Do not attempt to install your intercom system until you have read and thoroughly understood the installation pro
cedure. Aiphone’s warranty is void if system is installed in a manner other than described in this manual.
WIRING
Lay out your system in advance. Determine the exact location of each station.
We recommend a full complement of wire be installed, even though you may not initially be installing the maximum
number of stations available for your system. This way, should you decide to add a station later, you can avoid running
additional cables to existing stations. Do not connect wires to terminals CS,ED, or P3 unless appropriate equipment is used.
Speaker phone will not operate if these wires are connected parallel through system.
A maximum of 24 conductors is required for the TS-12K. A maximum of 18 conductors is required for the TS-6K.
Refer to the chart below and select the proper wire gauge to meet your requirements.
AWG WIRE SIZE
DISTANCE 550'
DIAMETER OF WIRE
DISTANCE
24 AWG
0.5 mm
200 m 250 m 280 m
22 AWG 20 AWG
1 700' 775'
0.65 mm 0.8 mm
18 AWG
875'
1.0 mm
320 m
Begin your installation with station #1. A space is provided at the left of the diagram to write in your color code.
Note the position of the C terminal at each station. Be sure you wire each station correctly.
After installing your second station we recommend that the power supply be connected to the + and ~ terminal lines at
a convenient location and that a test be made for calling and talking between each station. As each additional station is
installed retest between each station. Unplug power supply while making wiring connections.
ACTUAL TS-12K STATION TERMINAL LOCATION:
for connecting relative stations,
for power supply.
for talking and to be connected in common,
for receiving call and talking.
for accessory functions added to system
at later date.
for connecting door station.
for paging connection.
for door release or other remote control.
PI
- 12
©
(P3,
INSTALLATION LOR"wALL MOUNTINC©
1) Attach the mounting bracket to wall or single gang plaster
ring.
2) Remove the rubber feet from base of station.
3) Attach the handset cradle with supplied screws.
( INSTALLATION OL TERMINAL BOX )
(Can be mounted easily to wall or single gang box.)
1) Remove a screw and cover as shown.
2) Attach bottom case to wall or single gang box.
3) Wire terminals and replace cover.
TERMINAL IDENTIFICATIONS
EQUIPMENT AVAILABLE EOR USE WITH YOUR TS-K SPEAKER-PHONE
1
III
E3"
TS-6K: 6 call master station. Up to 7
masters may be connected.
TS-12K: 12 call master station. Up to
13 masters may be connected.
DS-B: Adaptor for door station.
IB-DA: Door station. Please see below
for other types of door stations.
EL-9S: Electric door release. Requires
separate transformer.
PA-B: Talkback paging and/or block
paging adaptor.
PG-K: Desk paging adaptor. Allows page
to be heard through all other connected
stations. Must be used in conjunction
with paging amplifier.
PS-12C: CSA & UL approved power
supply (available only in North America).
PS-12S: Power supply for system.
Available everywhere except in North
America.
SP-3: Paging speaker. Complete and
ready to install including round flush
mounting frame. Transformer installed
for 70V line operation. (Either N-S,
square frame or N-E, round frame is
available for SP-3 installation).
PG-U TYPE A: Paging adaptor for con
necting any amplifier and background
>
music source to your TS-K system.
Features paging volume, treble & bass
controls and automatic background music
cut out.
RY-P: Relay for local speaker cut out.
Local speaker cut out eliminates the
chance of feed back if a paging speaker is
located near station initiating page.
PG-3: 3-watt paging amplifier.
PG-lOA, PG-30A, PG-60A: UL & CSA
approved paging amplifier. lOW, 30W,
60W.
PG-lOB, PG-30B, PG-60B: Standard
paging amplifier. lOW, 30W, 60W.
C
TS-K SYSTEM WITH TWO DOOR STATIONS CONNECTED“^
Maximum of 2 door stations per system. Each door station may be connected to up to 4 masters.
STATION STATION
NOTE: Please select the most suitable door station from your application from the IB-series door stations (IB-FY not available
in U.S.A.).
STATION STATION
PS-12S
or
PS-12C
■
IB-DA IB-NA IB-RA IB-RAG IB-FY
-3 -
IB-JA