Aiphone TC-MF User Manual

^ AlPHONE
832870 TC-MB-l-0986 ®
TWO STATION INTERCOM

Models: TC-MB (Set)

TC-MF (Master station)

TC-MB (SET)
(3-7/16":
ROOM STATION DOOR STATION
TC-MF IB-DB
- INSTRUCTIONS -
( OPERATION ^
Door station calling: Momentarily depress call button. Talk and listen hands free to master. Do not push call switch during conversation.
Room station receiving: Pick up the handset and talk just as on a standard telephone.
Simultaneous conversation. Electronic tone call signal with volume control. Long battery life due to low current requirement. LED indicator for easy checking of battery life. Power source: DC 6 volt. Four Wi volt “C” batteries (room station incorporates battery compartment) or PS—6D power supply. Wiring and communication range: Single pair of wires — select the proper wire gauge to meet your requirements from the chart below.
Diameter of wire Distance
CALL VOLUME CONTROL
0.65mm 150m 230m
0.8mm 20AWG 750'
CALL BUTTON
22AWG
500'
( INSTALLATION }
* Connect terminal #1 on back of room station to terminal
#1 on door station. Then connect terminal #2 on room station to terminal #2 on door station. MAKE SURE YOUR WIRING IS CORRECT. Incorrect wiring will not allow call tone or voice communication.
* Insert four 1.5V “C” batteries (not included) in battery
compartment. + and — positioning of battery terminals is clearly indicated in the battery compartment.
PS-6D POWER SUPPLY
*Power supply is not required if master is powered by batteries.
IB-DB BACK VIEW
WALL MOUNTING INSTALLATION )
Room station:
Attach the mounting bracket with screws to wall or gang box. Insert the prongs of the bracket into the holes of the
body and pull the body downward. (Be careful not to attach the bracket upside down).
Door station: * Attach bottom case to wall or gang box. Connect wires
and insert front panel.
TC-MF MASTER
C ADJUSTING VOLUME CONTROL^
The incoming call tone volume may be adjusted to three levels by setting switch as desired.
LED FOR BATTERY CHECK
The system is designed for low current consumption providing longer battery life. Battery check LED is mounted on
the TC-MF master.
TC-MF MASTER
CONDITION #1
Lights normal during conversation.
1
CONDITION #2
* Becomes dark during
conversation.
- - vAdv-
Tj
FRONT,TERMINALS PANEL ' BRACKET
I / ^^^3® —
SCREW ; WIRING FOR ; CABLE
PANEL MOUNTING
SCREW (x2)
m iiQ: ffl] r; m
SET TO: LEFT MIDDLE
CONDITION #3
* Does not light during
conversation.
1
0
HANCi
Batteries are powerful enough to function the system.

BEFORE YOU INSTALL AND OPERATE THE EQUIPMENT - Prohibitions and precautions-

Operation;
1. DO NOT HOLD HOOK SWITCH DOWN WHILE PICKING UP HANDSET. THE CALL TONE SOUNDS THRU THE HANDSET RECEIVER ELEMENT AND COULD CAUSE HEARING DAMAGE.
Batteries get weaker but don’t have to be replaced yet.
Batteries are exhausted and must be replaced by new ones.
NEVER
Installation;
1. DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES.
2. Be sure to remove plug of power supply from AC outlet before you open the unit or make
wiring connections.
3. Avoid running the connecting wires thru doors, windows or between furniture, which may
pinch and disconnectect the wires.
NEVER
4. The intercom equipment must be installed in as dry and dust-free environment as possible. Maintenance;
1. Clean your intercom equipment with a soft cloth dampened with neutral household cleanser.
Never use thinner nor benzine, etc.
2. Do not splash water on the door station by hose, etc. We at AIPHONE are proud of our products. Our designers and engineers strive to bring you the finest in commu
nication equipment. Each item has been carefully tested and inspected before leaving our factory. Properly installed and used, your Aiphone intercom system should give years of trouble-free service.
'Xiphone uarrants its products to be free from detects ot material and workmanship unift'r normal use and sersice tor a period of one sear after delivers to the ultimate user and will repair tree oi charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under vxarrantv. Aiphone reserves unto itself the sole right to make the final decision whether there is a detect in materials and or workmanship; and whether or not the prod uct is within the warrants. This warrants shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside ot the factors'. This warrants’ does not cover batteries or damage caused bv batteries used m connection with the product. Thi-, warrants covers bench repairs onlv, and any repairs must be made at the shop or place des ignated in vsnling bv Aiphone. Aiphone w'lM not be responsible for anv costs incurred involving on site service calls.
Aiphone Co., Ltd., Nagoya, Japan Aiphone Corporation, Bellevue, Washington
TC-MB-l-0986 ©
WARRANTY
ALL OVER THE WORLD
t I t I g I W I iMgllllltrt
AIPHONE
PRINTED IN JAPAN