Special
Order
Products
TB-nM/D
Master Station with Selective Door Release
TB-10M/D 10-Call Master TB-20M/D 20-Call Master
- SUPPLEMENT TO TB-M INSTRUCTIONS -
The TB-M/D Intercom and Selective Door Control System is designed for communication between a central master
station and remote door stations. The TB-M/D adds door release to the standard TB-M system. All information
regarding installation other than the external control functions is included in the TB-M instructions. In addition to
communication to remote locations, the Master Station can selectively release the corresponding door strike or
maglock.
WIRING DIAGRAM: SYSTEM USED FOR SELECTIVE DOOR RELEASE
TB-10M/D
12+
12-
PS-18YC/A
+
-
To activate door
release, press
button located by
TRANSFER button.
Input
1
2
3
~
9
10
E
T
R
M
C
AC/
DC
1 ~
9
10
L
External
Terminal Block
TB-AD1
For Door #10
1
2
N
T
R
+
-
RY-PA
BLK
To convert RY-PA to N/C (normally
closed) contact: Move one yellow wire
from "NO" to "NC". (Internal
modification, soldering required.)
#1
YEL
BLK
RY-PA
#9
BLK
YEL
For Door #9
RY-PA
#10
TB-AD1
1
2
N
T
R
+
-
Momentary Closure for Station #1
Momentary Closure for Station #9
Momentary Closure for Station #10
YEL
Common for each closure
IE/IF Door
Station
1
2
AC Power
Releases
IE/IF Door
Station
1
2
Relays are activated
when the door
release button is
being pressed while a
station button is
selected.
x x
for Door
Individual Components for System:
TB-nM/D Master station with selective contact output capability (10, 20)
RY-PA Relay for selective output (1 per station requiring external contact)
PS-18YC/A 18V DC, 1.2A Power Supply (For Audio Systems)
PS-18C 18V DC, 2A Power Supply (For Audio/Video Systems)
TB-AD1 1 Audio Door Adaptor
TB-AD10 10 Audio Door Adaptor
TB-ADM10 10 Video Door Adaptor
IMPORTANT:
1. RY-PA must be used for each selective contact to
isolate AC voltage from the intercom circuit.
2. Extra contact connections and L are on the
external terminal block.
TB-M/D TERMINAL DEFINITIONS:
+ Power input (18V DC or 16V AC)
- Negative
1~10 Station number
E Common communication
M,C Master-to-Master communication
T Transmit to door station
R Receive from door station
S, S Output to call extension speaker
SEPARATE TERMINAL BLOCK:
1~10 (20) Selective negative for each channel
L Common Positive output for selective closure
Pg. 1
WIRING DIAGRAM: SYSTEM USED FOR DUAL FUNCTION OF EXTRA CONTACTS
Terminal Block
Equipment for each station that requires
both a constant closure and momentary
closure when a channel is selected:
2 RY-PA relays
1
L
DUAL FUNCTIONS FROM EACH CHANNEL:
BLK
BLK
RY-PA
#1
RY-PA
#2
YEL
YEL
Momentary closure #1
Constant closure #1
1 Diode (1N4001)
2
In TB-M/D Master
12+
12-
BLK
BLK
RY-PA
#1
RY-PA
#2
YEL
YEL
Momentary
closure #2
Constant
closure #2
OPERATION:
* POWER SWITCH ON THE BACK OF THE MASTER MUST BE ON FOR SYSTEM TO BE
OPERABLE.
1. When a station calls in, pick up the handset and press the selector button corresponding to the lit
LED.
2. Speak to the person at the remote station through the handset. The person at the remote station
speaks hands free.
3. To release the door at the calling party's location, press the "door release" button while still in
communication with the calling station. This will activate the corresponding relay as long as the
button is being held, which will activate the door release mechanism.
4. If both selective door release and a constant closure are used on a channel, the device connected to
the "constant closure" relay will be on as long as the channel is selected. The "momentary closure"
will only be active when the door release button is pressed.
5. When the conversation is completed, hang up the handset.
SPECIFICATIONS
Power Source: 18V DC or 16V AC at master. Use PS-18YC/A. PS-18C,
or AC Transformer (16V AC, 10VA or greater).
Communication: Handset at master
Hands free at sub station
Calling: Master to sub: By voice only.
Sub to master: Call button on sub activates tone and LED at master
Wiring: 2 conductors homerun from door to door station adaptor.
Four (4) common wires plus one (1) individual wire per station from door adaptor to
Master.
Use Aiphone #812202 (2 cond., 22AWG) or #812206 (6 cond., 22AWG) wire.
Wiring Distance:
Door to Adaptor: 210' with 22AWG; 495' with 18AWG.
Adaptor to Master: 500' with 22AWG; 1,200' with 18AWG.
For additional information about this system,
please refer to the TB-M instructions.
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Toll Free Technical Support
Phone: 1-800-692-0200
FAX: 1-800-832-3765
E-mail: tech-serv@aiphone.com
Pg. 2
TB-M/D Instr.
0598jd