Aiphone PC-359B-PC-454 INSTALLATION INSTRUCTIONS

PC-359B
Call Holding Circuit Board for Non-Aiphone Speaker and Call Button with
NEM, NDR, NDRM Systems
- INSTRUCTIONS -
The PC-359B call holding circuit board provides the latching function when a call is placed from a remote station on the NEM series Lamp Memory System. With this circuit board, a speaker and a "Normally Open" call button can be used as a remote station where a standard sub station cannot be used. The NEM system impedance is 20 ohms, so either use a 20 ohm speaker, or an 8 ohm speaker with the LT-1 matching trasformer.
WIRING DIAGRAM:
PC-359/B
(solder side view)
To "E" terminal of master
To "#" terminal of NEM master
9
8
7
7
7
6
Add jumper between "6" and "7"
5
To Speaker "-"
** 20
speaker
To Speaker "+"
Normally Open
*
1
4
3
2
2
* Note that speaker connection is on inner land pattern solder pad, not the one closest to the edge. ** When using an 8 speaker, add the LT-1 transformer shown below.
LT-1
20 (red)
8 (blue)To PC-359/B. To 8 speaker.
call button
SPECIFICATIONS:
Power Source: Supplied by Master Station (NEM, NDR, NDRM) Speaker: Use 20 ohm speaker, or 8 ohm speaker with LT-1 transformer Call Button: Normally open momentary contact Mounting: Conceal behind speaker or call button Terminations: Solder connections directly to PC board made by installer Wiring: 2 conductor shielded (1 common and 1 individual wire per remote) Wiring Distance: 420' w/ 22AWG, 1,000' w/ 18AWG Dimensions (HxWxD): 3-3/16" x 1-1/4" x 5/8"
TOLL FREE TECHNICAL SUPPORT: (800) 692-0200
TOLL FREE FAX LINE: (800) 832-3765
E-MAIL: tech-serv@aiphone.com
PC-359B Instr.
0404PHJS
Loading...