PC-359B
Call Holding Circuit Board for Non-Aiphone Speaker and Call Button with
NEM, NDR, NDRM Systems
- INSTRUCTIONS -
The PC-359B call holding circuit board provides the latching function when a call is placed from a remote station on the
NEM series Lamp Memory System. With this circuit board, a speaker and a "Normally Open" call button can be used as
a remote station where a standard sub station cannot be used. The NEM system impedance is 20 ohms, so either use
a 20 ohm speaker, or an 8 ohm speaker with the LT-1 matching trasformer.
WIRING DIAGRAM:
PC-359/B
(solder side view)
To "E" terminal
of master
To "#" terminal
of NEM master
9
8
7
7
7
6
Add jumper
between "6" and "7"
5
To Speaker "-"
** 20 Ω
speaker
To
Speaker
"+"
Normally Open
*
1
4
3
2
2
* Note that speaker connection is on inner land
pattern solder pad, not the one closest to the edge.
** When using an 8 Ω speaker, add the LT-1
transformer shown below.
LT-1
20 Ω (red)
8 Ω (blue)To PC-359/B. To 8 Ω speaker.
call button
SPECIFICATIONS:
Power Source: Supplied by Master Station (NEM, NDR, NDRM)
Speaker: Use 20 ohm speaker, or 8 ohm speaker with LT-1 transformer
Call Button: Normally open momentary contact
Mounting: Conceal behind speaker or call button
Terminations: Solder connections directly to PC board made by installer
Wiring: 2 conductor shielded (1 common and 1 individual wire per remote)
Wiring Distance: 420' w/ 22AWG, 1,000' w/ 18AWG
Dimensions (HxWxD): 3-3/16" x 1-1/4" x 5/8"
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
TOLL FREE TECHNICAL SUPPORT: (800) 692-0200
TOLL FREE FAX LINE: (800) 832-3765
E-MAIL: tech-serv@aiphone.com
PC-359B Instr.