NHR-3TS
Common Area
Call Station
NHX Nurse Center
DESCRIPTION:
The NHR-3TS Common Area Call Station for
the CommuniCare system provides call
annunciation outside of a common area
restroom, or an urgent staff call from a
designated staff call station.
With two corridor lamps, the NHR-3TS registers
at the master station as an independent calling
location, designated as a restroom or staff call
station. The lamps can be lit to indicate calls
from two areas.
Mounted into a standard 2-gang box, the
common area call station is used in conjunction
with the NHR-7A bathroom pullcord station for
common area restrooms, or the NHR-7A without
the cord attached for a staff call station.
OPERATION:
A call placed will register at the master station
as an urgent call. Either lamp on the NHR-3TS
will light, depending on the wiring of the call
station to the NHR-3TS. There can be two call
stations or groups of call stations associated with
each NHR-3TS, each lighting a separate corridor
lamp, but lighting the same LED on the master.
The call must be cancelled at the calling location
by moving the call switch to the upward position.
There is no communication associated with a
common area call station.
FEATURES:
• Provides call annunciation from common area
restrooms or staff call location
• Two corridor lamps, indicating calling location
• 2-gang mounting with stainless steel plate
• Wires the same as a patient station
Lamp
(Red)
Lamp cover
(x2)
Stainless steel cover
Aiphone Communication Systems 1700 130th Ave. NE Bellevue, WA 98005
(425) 455-0510 FAX: (425) 455-0071 http://www.aiphone.com
ARCHITECTS/ENGINEERS SPECIFICATIONS:
Common area call station shall be Aiphone model
NHR-3TS, with 22AWG stainless steel faceplate, two
corridor lamps with optional red bulb covers, and
removable lens covers.
A call from an urgent call station (NHR-7A) shall
activate the associated lamp, flashing continually
until reset at the calling station. Two lamps shall be
provided, allowing calls from two areas to register
as one call on the master, but distinguishable at the
calling location.
Wiring to CCU shall not exceed 3 twisted pair if no
zone indicator light is included, or 3 twisted pair plus
one wire if a zone indicator light is used. Cable size
greater than 22AWG shall not be acceptable.
Physical size of the common area call station shall
not exceed 4-3/4” high by 4-9/16” wide, and shall
mount on a standard 2-gang electrical box.
Equipment shall be UL 1069 listed, and system
components shall be provided by a manufacturer
having ISO 9001 certification for quality standards.
CONTROLS AND INDICATORS:
• Two lamps, with removable red bulb covers
• Two lens covers
SPECIFICATIONS:
Power source: Provided by NHX-80X
Capacity: Any number. Each NHR-3TS counts as
one (1) station on system
Wiring: 3 twisted pair shielded low capacitance
cable (12 pF/Ft) from NHX-80X
Aiphone #862208
With NHR-3A-4 Zone Indicator Light:
3 twisted pair + 1 common wire per zone
Aiphone #862208
Wiring Distance: 165’ w/22AWG
Material: Stainless steel faceplate
ABS plastic lens covers
Dimensions NHR-3TS
(H x W x D): 4-3/4” x 4-9/16” x 2-1/2”
Certification: UL 1069 Listed
C-UL Canadian Standard C22.2
MOUNTING:
Stainless steel
faceplate
with 2 lens covers
Product specification subject to change without notice.
2-gang box
Health Care Systems
NHR-3TS-SS 95368 0797