Aiphone NE-NVP-RA INSTALLATION INSTRUCTIONS

NE-NVP-RA
Vandal Proof Sub Station for NEM System
Special Order Products
Requires surface mount box
SBX-NVP
ADA
Americans with
Disabilities Act
- INSTRUCTIONS -
The NE-NVP-RA sub station is vandal proof, and can be used with the NEM or the NEM-RS systems. Designed for Rescue Assistance applications and ADA compliance, this unit features Emergency and Braille signage, a large red call button, and "Call Placed" and "Help Coming" LED indicators. Remote indicators can be added for better visibility of a station's status. A standard NEM master requires a manual reset button at each location, or the master station can be equipped with a reset button (NEM-nRS version). The NE-NVP-RA is designed to be surfaced mounted, requiring the SBX-NVP surface mount box. Tamper proof screws are provided, along with a wrench for installation.
NEM-nRS Master
PS-2410A or PS-24E
+
-
1 2 3
Use a designated
~
wire from each no. terminal to sub
20
station's RED wire.
E S H +
-
NE-NVP-RA
Red
Green jumper
(Do not cut)
Blue
Purple
Black
Yellow
Orange
NE-NVP-RA
Red
Green jumper
(Do not cut)
Blue
Purple
Black
Yellow
Orange
WIRING DIAGRAM FOR SYSTEM WITH OVERHEAD LAMPS AND A RESET BUTTON. Standard NEM master used.
NE-NVP-RA
Red
Green jumper
(Cut)
Blue
Purple
Black
Yellow
Orange
Blue Blue
NAR-2A*
Blue Blue
Blue
NBY-4A
"Call Activation" light
NBY-4A
"Help Coming" light
Blue
* Reset Button:
(Any normally closed button or keyswitch. Not required when using the NEM-RS master.)
PS-2410A or PS-24E
+
-
NEM-n Master
1 2 3
Use a designated
~
wire from each no. terminal to sub
20
station's RED wire.
E S H +
-
Pg. 1
OPERATION:
1. When a sub station places a call, the "Call Placed" (Red) and "Help Coming" (Green) LEDs on the sub station light.
2. When a call is answered, the red "Call Placed" LED on the sub turns off. The green "Help Coming" LED stays on.
3. When the master station's reset button is pressed or if a remote reset switch is activated, all of the call indicator lights will go off.
4. If overhead lamps are installed in the system, they will light in the same way that the LED's light, as descirbed above.
BRAILLE SIGNAGE:
The NE-NVP-RA is equipped with Braille signage for the visually impaired. ON TOP OF UNIT:
EMERGENCY "EMERGENCY - CALL FOR HELP"
ON BOTTOM OF UNIT:
"PUSH BUTTON. TONE INDICATES CALL PLACED"
Plating material is .012" aluminum with 5 letter spacing.
SPECIFICATIONS:
Power Source: Supplied by master station Speaker: 20 ohms, 3" diameter, water proof and puncture resistant, 2.5 oz. ceramic magnet Call Button: Single pole, single throw (SPST), normally open (N/O) Faceplate: 11 gauge carbon steel with powder-coated white baked epoxy finish Call Annunciation: Pressing call button at sub latches call at NEM master until answered Communication: Hands free at sub. Master is push-to-talk or VOX handset Mounting Hardware: Tamper proof screws Terminations: Color-coded prewired pigtails Wiring: With remote reset switch: 4-conductor homerun from each sub, or 3 common wires plus 1
individual wire per sub station, looped. With NEM-RS master: 4-conductor homerun from each sub, or 3 common wires plus 1 individual wire per sub station, looped. Shielded wire is recommended. Use Aiphone #822206 for homerun wiring, #822210 for up to 6 stations
on each run, or #822220 for up to 17 stations on each run. Wiring Distance: 420' with 22AWG; 1,000' with 18AWG. Dimensions (H x W x D):NE-NVP-RA alone: 7-1/2" x 5-1/2" x 2". With SBX-NVP: 8-5/8" x 6-5/8" x 2-1/4"
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
TECHNICAL SUPPORT E-MAIL:
tech-serv@aiphone.com
NE-NVP-RA Instr.
Pg. 2
0698bkjd