Aiphone NE-NVP-RA User Manual

Special Order Products
NE-NVP-RA
Vandal Proof Sub Station with Dual Master NEM System
Requires surface mount box
SBX-NVP
- INSTRUCTIONS -
WIRING DIAGRAM: DUAL MASTER SYSTEM USING NEW-5 ADAPTORS AND NEM-nRS MASTER STATIONS
NE-NVP-RA
NE-NVP-RA
red
black orange
yellow
NEM-10/RS
PS-2420UL
+
-
NE-NVP-RA
red
black orange
yellow
= Reset switch
1 2 3 4 5 6 7 8 9
10
E
H
Y
Q
S +
-
red
black orange
yellow
Relay input connection
12V DC Power
NEW-5
1S 1E
2S 2E
3S 3E
4S 4E
5S 5E
MA1 MB1 MA2 MB2 MA3 MB3 MA4 MB4 MA5 MB5
MAE MBE
MAH MBH
MAY MBY
MAQ MBQ
12V+
12V-
-
+
NOTE: To reduce the level of crosstalk, use separate 12V DC power sources for each set of sub stations on each NEW-5. (1 per 5 stations on the system.)
NE-NVP-RA
NEW-5
1S 1E
2S 2E
5S 5E
MA1 MB1 MA2 MB2 MA3 MB3 MA4 MB4 MA5 MB5
MAE MBE
MAH MBH
MAY MBY
MAQ MBQ
12V+
12V-
red
black
orange
yellow
+
-
PS-12C
ADA
Americans with
Disabilities Act
NE-NVP-RA
red
black
orange
yellow
NEM-10/RS
1 2 3 4 5 6 7 8 9
10
E
H
Y
Q S
+
-
Relay input connection
PS-2420UL
+
-
OPERATION:
1. When a sub station places a call, the "Call Placed" (Red) LED on the sub station light.
2. When a call is answered, the red "Call Placed" LED on the sub turns off, and the green "Help Coming" LED turns on.
3. When the master station's RESET button is pressed, the green "Help Coming" LED's will go off on any sub station that has been answered since the last time the Reset button has been pressed.
4. If overhead lamps are installed in the system, they will light in the same way that the LED's light, as descirbed above.
BRAILLE SIGNAGE:
The NE-NVP-RA is equipped with Braille signage for the visually impaired.
ON TOP OF UNIT:
EMERGENCY "EMERGENCY - CALL FOR HELP"
ON BOTTOM OF UNIT:
"PUSH BUTTON. TONE INDICATES CALL PLACED"
Plating material is .012" aluminum with 5 letter spacing.
SPECIFICATIONS:
Power Source: Supplied by master station Speaker: 20 ohms, 3" diameter, water proof and puncture resistant, 2.5 oz. ceramic magnet Call Button: Single pole, single throw (SPST), normally open (N/O) Faceplate: 11 gauge carbon steel with powder-coated white baked epoxy finish Call Annunciation: Pressing call button at sub latches call at NEM master until answered Communication: Hands free at sub. Master is push-to-talk or VOX handset Mounting Hardware: Tamper proof screws Terminations: Color-coded prewired pigtails Wiring: With remote reset switch: 4-conductor homerun from each sub, or 3 common wires plus 1
individual wire per sub station, looped. With NEM-RS master: 4-conductor homerun from each sub, or 3 common wires plus 1 individual wire per sub station, looped. Shielded wire is recommended. Use Aiphone #822206 for homerun wiring, #822210 for up to 6 stations
on each run, or #822220 for up to 17 stations on each run. Wiring Distance: 420' with 22AWG; 1,000' with 18AWG. Dimensions (
H x W x D
): NE-NVP-RA alone: 7-1/2" x 5-1/2" x 2". With SBX-NVP: 8-5/8" x 6-5/8" x 2-1/4"
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
TECHNICAL SUPPORT E-MAIL:
tech-serv@aiphone.com
NE-NVP-RA Dual
Pg. 2
Master Instr.
0703bkjs