Aiphone NEM-LD INSTALLATION INSTRUCTIONS

Special Order Products
NEM-LD
NEM Lamp Memory System for Long Distances and Elevators
NEM-n-LD Master Station
IF-DA-NLD and IE-JA-NLD Sub Stations
- INSTRUCTIONS -
The NEM Long Distance Lamp Memory System is designed for communication with remote locations up to 4,000' away, or to each elevator in a building. Sub stations are available in surface or flush mount styles, and require a separate circuit board (PC-359B) to be added for the call-in function. Three wires are required to each sub station.
WIRING DIAGRAM:
PC-359B
1 2
IE-JA-NLD
1
2
2 3 4 5
Blk
Blk 6 7
3
7
NEM-20-LD
1 2 3 ~
20
E
H 7 7 8 9
PS-2410A
or
PS-24E
+
-
Individual Components for NEM-LD System:
NEM-n-LD Master station (10, 20, 30, 40-station) for Long Distance IE-JA-NLD Flush mount long distance sub with stainless steel cover IF-DA-NLD Surface mount long distance sub, brown plastic PC-359B Call holding circuit board for sub station, mounted externally PS-2410A 24V DC Power Supply (for 10 and 20 station masters) PS-24E 24V DC, 2A Power Supply (for 30 and 40 station masters)
IF-DA-NLD
1 2
Blk Blk
WHT Wire
Solder pads: Numbered by location on board.
To Blk To Blk
PC-359B
PC-359B (Solder side view)
1
2
2
To 1 To 2
3
4
1 2 2
3 4 5 6 7 7 7 7 8 9
5 6 7
9
8
7
7
7
SUB STATION MOUNTING: NEM-LD TERMINAL DEFINITIONS:
IE-JA-NLD: 2-gang electrical box + Positive 24V DC
- Negative
IF-DA-NLD:Surface mounts to 1-gang box 1~40 Station number
E Common communication H Provides power to sub station
Pg. 1
OPERATION:
1. When a sub station places a call, the red channel LED indicator lights and a call tone rings at the master. The tone and light will remain activated until the call is answered, which is the primary function of the PC-359B. The LED indicator at the sub station will be lit from the time the call is placed until it is answered.
2. If the master station is talking to another sub station, a new call from another sub station will light the LED, but the call tone will not be heard.
3. When the call is answered, the LED on the master goes off. The person at the master uses the push-to-talk, release-to-listen button, or picks up the handset to speak (with NEM-nA masters). The LED at the sub station will go off when the master answers.
4. When the conversation is completed, the OFF button to the left of the station selector button must be pressed to disengage the call.
SPECIFICATIONS:
Power Source: 24V DC at master. Use PS-2410A or PS-24E. Communication Output: 500mW at 20 ohms Communication: Push-to-talk, release-to-listen or VOX handset at master.
Hands free at sub station.
Calling: Master to sub: By voice only after pretone.
Sub to master: Call tone and LED, remaining activated until call is answered.
Wiring: 2 common plus 1 individual per sub, looped; or 3 conductors homerun
to each sub. Shielded cable is recommended. Use Aiphone #822203 for homerun wiring, #822206 for 4 stations
on each run, or #822210 for up to 8 stations on each run. Wiring Distance: 2,000' with 22AWG; 4,000' with 18AWG. Dimensions (H x W x D): IE-JA-NLD: 4-1/2" x 4-9/16" x 1-9/16"
IF-DA-NLD: 5-1/8" x 3-7/8" x 1-1/8"
TOLL FREE TECHNICAL SUPPORT:
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071
TECHNICAL SUPPORT E-MAIL:
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
NEM-LD
tech-serv@aiphone.com
Pg. 2
1098jd