The NDR Lamp Memory and External Control System is designed for communication between a central master
station and remote intercom stations. In addition to communication to remote locations, an external device can
be activated, such as activating a CCTV camera when the associated sub station is selected, or selectively
controlling the corresponding door strike or maglock. All other features, functions, and components are the same
as the standard NEM system.
WIRING DIAGRAM: SYSTEM USED FOR CCTV CAMERA CALL-UP
NDR-20A
1
2
NE-NVP
Red
NA-NE
Red
3
~
YEL
BLK
Blk
Grn
Grn
Closure for Station #1
RY-PA
#2
YEL
BLK
Blk
Grn
Closure for Station #2
RY-PA
#3
YEL
Terminal Block
20
BLK
Leave green
jumper intact
RY-PA
#1
Equipment for each station that requires
both a constant closure and momentary
closure when a channel is selected:
2 RY-PA relays
1 Diode (1N4001)
E
External
Terminal Block
1
2
3
~
20 L
PS-2410A
+
-
Individual Components for System:
NDR-n Master station with selective contact output capability (10, 20, 30, 40)
NDR-nA Master station w/handset and selective contact output capability (10, 20, 30, 40)
ND-20AS 20-call Add-on Selector with selective output capability
ND-40AS 40-call Add-on Selector with selective output capability
RY-PA Relay for selective output (1 per station requiring external contact)
PS-2410A 24V DC, 1A Power Supply for 10-20 station systems
PS-24E 24V DC, 2A Power Supply for 30-40 station systems
N-series Any model sub station with NA- or NE- prefix
IMPORTANT:
1. RY-PA must be used for each additional contact
to isolate AC voltage from the intercom circuit.
2. Extra contact connections and L are on separate
terminal block. NDR-30/40 have two terminal blocks.
H
+
-
NE-DA
1
2
Blk
Wht
Normally Open contacts remain
closed as long as master has sub
station selected.
Closure for Station #3
DUAL FUNCTIONS FROM EACH CHANNEL:
BLK
RY-PA
#1
RY-PA
#2
BLK
BLK
YEL
YEL
Momentary closure #1
Constant closure #1
RY-PA
#1
RY-PA
#2
YEL
YEL
1
L
2
NEM Master
H
BLK
+
-
NDR TERMINAL DEFINITIONS:
+ Positive 24V DC
- Negative
1~40 Station number
E Common communication
H Positive output for constant closure
L Positive output for selective closure
Momentary
closure #2
Constant
closure #2
Pg. 1
WIRING DIAGRAM: SYSTEM USED FOR SELECTIVE DOOR RELEASE
NDR-20A
1
2
3
NE-JA
1
NE-JA
1
NE-DA
1
~
To activate
door release,
press button
located above
TALK button.
PS-2410A
+
-
20
E
H
+
-
1
2
3
~
20 L
External
Terminal Block
BLK
RY-PA
#1
YEL
BLK
2
3
4
RY-PA
YEL
#2
RY-PA
BLK
To convert RY-PA to N/C
(normally closed) contact:
Move one yellow wire from
"NO" to "NC". (Internal
connection, soldering
required.)
#3
2
3
4
YEL
2
Blk
Wht
Closure for Station #1
Closure for Station #2
Closure for Station #3
Common for each closure
Normally Open contacts
are maintained when the
door release button is
being pressed while a
station button is selected.
x x
AC Power
for Door
Releases
OPERATION:
* POWER SWITCH MUST BE ON FOR SYSTEM TO BE OPERABLE.
1. When a station calls in, press the selector button corresponding to the lit LED.
2. To speak to the person at the remote station, press the TALK button or pick up the handset. Release TALK
button to hear reply. Communication via the handset is VOX (voice actuated).
3. If the extra contacts are used as shown in the "camera call-up" diagram, activating a device that is to remain
on for the duration of the call, the station's relay will stay activated as long as the selector button is depressed.
4. If the extra contacts are used as shown in the "selective door release" diagram, press the "door release" button
while the selector button is depressed. This will activate the corresponding relay as long as the button is being
pressed, which will activate the door release mechanism.
5. When the conversation is completed, press the OFF button to the left of the station selector button.
Hang up handset.
SPECIFICATIONS
Power Source: 24V DC at master. Use PS-2410A (NDR-10, 20) or PS-24E (NDR-30, 40).
Commun. Output: 500mW at 20 ohms
Communication: Push-to-talk, release-to-listen (TALK button) or VOX handset at master.
Hands free at sub station.
Calling: Master to sub: By voice only after pretone.
Sub to master: Call button on sub activates tone and LED at master,
remaining active until answered.
Wiring: 2 conductors homerun to sub station, or loop multi-conductor with 1 common
+ 1 individual wire per sub station on wire run.
Separate 2 conductor from RY-PA to external device.
Shielded cable is recommended. Use Aiphone #822202 (22AWG)
or #821802 (18AWG) wire (2 cond.).
Wiring Distance: 420' with 22AWG; 1,000' with 18AWG.
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
For additional information about this system,
please refer to the standard NEM instructions.
Toll Free Technical Support
Phone: 1-800-692-0200
FAX: 1-800-832-3765
Pg. 2
NDR Instr.
1198jd