Aiphone NB-L User Manual

831772 1187®
O AlPHONE
FLUSH-MOUNT ROUND SPEAKER

MODEL;

INSTALLATION MANUAL
INSTALLATION
1. Open a hole of 150 mm0 (5-7/8"</>) in the ceiling.
2. Hook the speaker at one side to a spring of holder, and connect wires.
3. Hook the other side of the speaker, by pulling spring, and locate the speaker in the center of the hole.
* Flush-mounting to ceiling, using NBZ-M square frame;
1. Open a hole of 150 mm^ (5-7l8"(p) in the ceiling.
2. Attach the square frame to the speaker from the back.
3. Hook the speaker at one side to a spring of holder, and connect wires.
4. Hook the other side of the speaker, by pulling spring, and locate the speaker in the center of the hole.

NB-L

(Sub station for NEM, NEM-A)
WIRING
(1) NB-L sub station, with call button;
n: varies by master
station model.
Aiphone Co., Ltd., Nagoya, Japan Aiphone Corporation, Bellevue, Washington
NB-L-I (E) 1187A
BLU : Blue GRN : Green BLK ; Black RED : Red ORG : Orange
(2) When corridor lamp is installed;
Connect wires on the connector (female) and attach to the male connector. When corridor lamp is installed, cut off green wire.