Aiphone MYW-CA User Manual

83070400 1092 @
® AlPHONE
PanTilt Separate Camera Adaptor
Model;
MYW-CA
(Camera adaptor)
V
MYW-CA is a surface-mount box for attaching MY-CA PanTilt video door station inside, so that MY-CA can work as surveillance camera.
INSTALLATION — How to mount MY-CA into MYW-CA

1. Removing the MY-CA chassis;

Loosen the tamper-proof screw on front case, and remove the back frame. Unscrew at one point, and open the chassis. Pull off CN102 connector, and then reattach the chassis.
When reattaching the chassis, be careful that the weather-stripping
(string) should rest attached. MY-CA
INSIDE CHASSIS
-WEATHER STRIPPING

2. Connecting two leads to MY-CA;

Locate the MY-CA unit inside the MYW-CA box. Connect two black and white leads to AI, A2
terminals on MY-CA. Wiring is non-polarized. Attach back plate with all 6 screws securely.
WEATHER-STRIPPING
BACK FRAME
SCREW (6)— (supplied)
BACK PLATE
MY-CA
CAMERA UNIT
TAMPER-PROOF SCREW
MY-CA (without back frame)
J
COVER
CN102
Remove a seal on camera cover before mounting MY-CA. Be careful not to scratch the cover surface. To clean, use soft cloth.

3. Installing the MYW-CA unit;

This shows an installation example of MYW-CA camera unit, along with lE-JA audio door station, and DP-600Z motion detector.
At the entry (under the eaves)
MOTION DETECTOR DP-600Z (Instructions
furnished with DP-600Z)
Adjust MYW-CA direction with these 2 screws and the center hexagonal bolt.
WOOD SCREW (4)
INSIDE THE HOUSE
6-wire cable (approx. 1.5m/5‘ long)
BLUE YELLOW RED BROWN BLACK WHITE (Each pair wiring is non-polarized)
TERMINAL BOARD (locally available)
or WIRE NUTS
to; Main video monito!
!■ to; Audio door station
to; Motion detector
Mounting accessories;
Attach the mounting base with 4 wood screws, and the arm with hexagonal bolt.
WOOD SCREW (4)
The MYW-CA cable should be "U"-shaped to allow easy run off of water, etc.
AUDIO DOOR STATION
lE-JA
As shown, mount the MYW-CA unit to the hardware supplied. Provide a terminal board locally available, on which connect wires from main video monitor, motion detector & door station. Water-proof the junction parts of the cable, if exposed.
!ito
HEXAGONAL BOLT & WASHER
SCREW & WASHER (2)
and SCREW (6) for back plate
--------
WIRING DIAGRAM
33V22AWG)
(l) When motion detector and audio door station is not installed, have each BLACK/WHITE and RED/BROWN wires insulated. (D The locator LED is lit on the lE/IF door station, only when MYW-CA is working. IF-DA
To cut off the I.ED all the time, open the case and remove either lead from the PC board.
In MY-ICD system, use PS-18C/D power supply when DP-600Z is installed.
165722AWG)
ROOM STATION
PC BOARDS
LED lead
Image viewing area
SPECIFICATIONS
* Power source: Supplied by main room station. * Dimensions: * Weight: ApproK. 850g (1.87 lbs.) including mounting
* Max. distance to object:
* Image viewing area:

Opeationai notes;

In night time, pan-aiid-tilting operation may cause flickering on the monitor, but this is not a unit disorder. When the system with DP-600Z motion detector is powered on, it may happen that a call will be initiated by itself. Wait for approx. 15 seconds after powered on, as the system performance can be unstable.
Aiphone Co., Ltd., Nagoya, Japan Aiphone Corporation, Bellevue, WA, USA
HxWxD: 163 X 121 x52 (6-1/2" x 4-3/4" x 2”)
accessories It is suggested to locate the MYW-CA at approx.
3m/10’ distance to the viewing area, providing spotlighting illuminatin for the night.
At 3m/10' distance; 4.7m/16' vertically 8.4m/28' horizontally captured by pan-and-tilting operation.
* Vertical (tilting)
The outer angle is obtained when camera is pan-and-tilted, while the inner angle is for fixed camera position.
® AIPHONE
MYW-CA-I(E) 1092B
4.7m/16'
8.4m/28'
3m/10A
COMMUNICATION SYSTEMS
HOME BUSINESS INDUSTRY.
HOME. BUSINESS. INDUSTRY.
Printed in Japan (E)