Aiphone MKW-M User Manual

- INSTRUCTIONS -
The MKW-M adaptor converts a standard CCTV camera's signal to a 2-wire signal, compatible with the MK-1GD, MK-2MCD, and MY series Black & White Video systems. This allows the utilization of a black & white CCTV camera and a separate audio door station (JA-D)* to be used in place of an MK video door station. A motion detector or other activation device can be connected to the Sensor input to trigger the system. The CCTV camera can also be connected to a standard CCTV system for continual viewing and/or recording. The unit is equipped with a relay output to trigger an external device, such as a DVR or video switcher whenever the audio and video to the Aiphone monitor is on.
SENSOR RELAY MASTER AUDIO
OUT IN
75 OHM
NC NC NO NO A1 A2 1 2
VIDEO
OFF ON
WIRING DIAGRAM: MKW-M Modulator for Standard CCTV camera and Audio Only door station
MK or MY Monitor
or Adaptor*
A1 A2
B1 B2
PS-1820UL
+
+
-
Constant video output for CCTV monitor, DVR, etc.
Normally Open contact for remote device activation (i.e. video switcher, DVR, etc.)
*COMPATIBLE MODELS:
MK-1GD
MK-2MCD MY-CU MYW-P1L MYW-P3L MYW-P10L
-
NOTES:
1. JA-D is the only compatible door station with this unit.
2. Video Output is optional. If not used, set 75 Ohm switch to ON position.
3. SENSOR input can be used only if there is no JA-D door station connected. When used, the camera will turn on when the sensor device is activated.
JA-D*
(Optional, only if Sensor
input is not used)
1 2
CCTV Camera
75 Ohm, 1V Peak-to-peak (Independently powered)
Remote Activation*
(Optional, only with no JA-D
installed)
* Signaling device that provides a
Normally Closed momentary
contact.
MKW-M
MASTER
A1 A2
AUDIO
1 2
VIDEO IN
VIDEO OUT
SENSOR
NC NC
RELAY
NO NO
When VIDEO OUT is connected, set
75 Ohm switch to OFF position.
AIPHONE
Pg. 1
INTERNAL ADJUSTMENT WHEN JA-D AUDIO DOOR STATION IS INCLUDED:
INSTRUCTIONS:
1. Open unit by removing 5 small screws and lifting off cover.
2. Locate Jumper labeled JP1 on the right side of the PC board.
3. Remove the jumper completely, or move it so it is on just one of the posts.
4. Replace the cover and the 5 screws.
OPERATIONS
Activation of the camera from a Monitor:
1. The CCTV camera can be viewed on any of the MK monitors in the system by pressing the MONITOR button. When the video is activated, the audio door station will be activated to transmit audio to the monitor station. To initiate 2-way audio with the outdoor location, pick up the handset and speak. When the han dset is hung up, audio and video will turn off.
2. To turn the monitor off, press the MONITOR button again. Otherwise, it will automatically time out after approximately 2-1/2 minutes.
Activation of a camera by the Audio Door Station:
1. When the call button is pressed on the JA-D door station, the monitor will turn on with the image from the CCTV camera, and the chime will sound. The monitor and audio will stay on for approximately 45 seconds if not answered.
2. Pick up the handset to answer, and hang up to conclude. The monitor will turn off when the handset is hung up.
Interfacing Video with Other Systems:
1. VIDEO OUT connection simply passes the composite video signal on to a standard CCTV system, such as a monitor, input on a switcher, or DVR. This video signal is live as long as the camera is powered. When using this feature, set the 75 OHM switch to the OFF position.
2. SENSOR input allows a motion detector or other activation device to remotely turn on the camera. Use any device with a Normally Closed contact. If an audio door station (JA-D) is included, the sensor input cannot be used.
3 RELAY connection provides a normally open contact closure that can be connected to an external system. This
contact will be closed whenever the Aiphone system is turned on. This can be wired into a record input on a DVR or any other external device that needs to be notified when the video and audio is activated to the Aiphone monitor.
SPECIFICATIONS:
Power: Supplied by main Monitor/Adaptor Video Input & Output: Composite 1V Peak-to-Peak, NTSC Connector: BNC Audio Door input: Use JA-D surface mount door station only Relay: Normally open output Wire: 18AWG, 2-conductor, non-shielded, solid
Aiphone wire # 871802 Wiring distance: Max. 330' from MKW-M to MK/MY monitor or MYW adaptor Dimensions: 1-5/8"H x 7"W x 4"D
FCC Class B Verification
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device , pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: — Reorient or locate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help.
Note:
Only information pertaining to the connection and operation of the MKW-M and devices interfacing with it are included here. For complete installation, wiring, and operational information about the MK or MY system, please refer to the Installation Manual included with the product.
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071
Toll Free Technical Support:
1-800-692-0200
FAX: 1-800-832-3765
E-mail tech-serv@aiphone.com
Pg. 3
MKW-M Instr.
1206JDJS